ABB 1SDA068171R1 Moulded Case Circuit Breaker - IEC 60947-2

Manufacturer
ABB
Part number
1SDA068171R1

Quick Summary

Moulded Case Circuit Breaker ABB 1SDA068171R1 protects industrial power distribution from faults and overloads in automation panels. Root causes like transient faults and surges can halt production; this device offers reliable, fast protection with a 30 ms opening time. Designed as a four-pole XT2 unit with front terminals at 690 V, it handles up to 160 A and 150 kA Ics/Icu to keep critical loads safe. This model carries CE conformity and independent GL and LR certificates, plus a DoC for Tmax XT2, underscoring global compliance. Installation is streamlined by front-connection and standardized dimensions, delivering lower assembly time and easier maintenance, which translates into lower total cost of ownership.

Product Information

Extended Description

1SDA068171R1 ABB: BREAKING PART TMAX XT2L 160 FIXED FOUR-POLE WITH FRONT TERMINALS
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
E-Number (Finland)
3640557
E-Number (Norway)
4379741
EAN
8015644696177
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.2 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
150 mm
Package Level 1 Height
215 mm
Package Level 1 Depth / Length
135 mm
Package Level 1 Gross Weight
1.3 kg
Package Level 1 EAN
8015644696177
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Breaking Part
Version
F
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 150 kA | (230 V AC) 150 kA | (240 V AC) 150 kA | (380 V AC) 120 kA | (415 V AC) 120 kA | (440 V AC) 100 kA | (500 V AC) 60 kA | (525 V AC) 36 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 85 kA | (500 V DC) 3 Poles in Series 85 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 150 kA | (230 V AC) 150 kA | (240 V AC) 150 kA | (380 V AC) 120 kA | (415 V AC) 120 kA | (440 V AC) 100 kA | (500 V AC) 60 kA | (525 V AC) 36 kA | (690 V AC) 18 kA | (250 V DC) 2 Poles in Series 85 kA | (500 V DC) 3 Poles in Series 85 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Short-Circuit Performance Level
L
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Four-pole XT2 front-terminal design simplifies wiring and reduces panel depth, cutting installation time and risk of terminal errors. This translates into faster commissioning and safer maintenance in compact control cabinets used for manufacturing lines. Fault-current capability up to 150 kA Ics/Icu at multiple voltages ensures reliable interruption during faults, reducing the likelihood of equipment damage and unplanned downtime. The 690 V AC / 1000 V insulation voltage rating and 50/60 Hz compatibility support widespread European and global distribution systems, enabling straightforward panel upgrades and system expansion. Electrical durability of 120 cycles per hour with 8000 electrical operations and mechanical durability of 240 cycles per hour with 25000 mechanical cycles provide long-life protection in high-demand environments, lowering replacement and maintenance costs. CE conformity, GL and LR certifications, and a DoC for Tmax XT2 mitigate regulatory risk and streamline procurement for global projects. Front-terminal installation and standardized dimensions also simplify retrofits and replacements, improving serviceability and reducing field labor time.

Get a Quick Quote for a ABB 1SDA068171R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA068171R1? Enquire Now

FAQs

Front-terminal connection simplifies wiring, reduces assembly time, and minimizes field wiring errors. When planning installation, ensure clearance for front-access terminals, verify compatible panel cutouts, and follow the 690 V nominal rating with appropriate conductor sizing to achieve reliable fault clearance without overheating.
Key specs include 4P XT2 construction, 690 V rated voltage, 160 A rated current, and high short-circuit capacity up to 150 kA (Ics/Icu). The 30 ms opening time supports fast fault isolation, while 50/60 Hz compatibility ensures operation across common industrial networks.
Yes. With SACE Tmax XT lineage, four-pole XT2 configuration, front terminals, and a robust 150 kA breaking capacity, it is well-suited for transformer feeders and MCC protection in industrial control panels, delivering reliable protection with easy integration into existing Tmax XT families.
The device carries CE conformity with an EC Declaration of Conformity for Tmax XT2, along with GL and LR certificates. A DoC supports regulatory compliance, while RoHS and REACH declarations help with material and environmental standards.
Durability figures show 8000 electrical cycles and 25000 mechanical cycles, meaning longer service life and fewer replacements. Front-terminal design speeds commissioning and maintenance, reducing labor costs. The device also minimizes downtime during faults, supporting a faster return on investment in automated plants.