ABB 1SDA068764R1 Moulded Case Circuit Breaker - TMF 4P CE
Part Number: 1SDA068764R1
Quick Summary
Moulded Case Circuit Breaker ABB 1SDA068764R1 provides reliable overcurrent protection for industrial automation systems. Engineers often grapple with nuisance trips and space-constrained control cabinets, making quick installation and dependable performance essential. It complies with CE conformity under EC Declaration of Conformity, RoHS and REACH declarations, and TSCA compliance, underscoring regulatory readiness. By combining front-terminal access with a 4-pole TMF release and a 32 A main current, it supports safe, compliant protection with reduced wiring time. Designed for panel builders and maintenance teams, it aligns with existing SACE FORMULA components to streamline procurement and spare-part compatibility, delivering business continuity in critical manufacturing environments.
Product Information
Extended Description
1SDA068764R1 ABB: C.BREAKER FORMULA A1N 125 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 32-400 A
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Environmental Information - Formula A1-A2 | Breakers - Packaging disposal information
Order Code US and Canada
AAN032TW-4
EAN
8015644030049
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
60 mm
Product Net Weight
1 kg
Package Level 1 Units
1 piece
Package Level 1 Width
136.5 mm
Package Level 1 Height
124 mm
Package Level 1 Depth / Length
110.5 mm
Package Level 1 Gross Weight
1.05 kg
Package Level 1 EAN
8015644030049
Product Main Type
SACE FORMULA
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Electrical Durability
1500 cycle
Mechanical Durability
Nr. Operations 8500 cycle
Number of Poles
4P
Opening Time
CB with SOR 15 ms | CB with UVR 15 ms
Power Loss
at Rated Operating Conditions per Pole 4 W
Rated Current (In)
Main Circuit 32 A
Rated Impulse Withstand Voltage (Uimp)
6 kV
Rated Insulation Voltage (Ui)
690 V
Rated Operational Voltage
550 V AC | 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 9 kA | (440 V AC) 6.25 kA | (480 V AC) 4.5 kA | (500 V AC) 2.5 kA | (250 V DC) 2 Poles in Series 5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 100 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 25 kA | (480 V AC) 18 kA | (500 V AC) 10 kA | (250 V DC) 10 kA
Rated Uninterrupted Current (Iu)
125 A
Release
TMF
Release Type
TM
Short-Circuit Performance Level
N
Standards
IEC
Sub-type
A1
Terminal Connection Type
Front
Data Sheet, Technical Information
1SDC210032D0204
Declaration of Conformity - CE
EC Declaration of Conformity Formula DSA A1
Wiring Diagram
Wiring diagram FORMULA A1-A2
Instructions and Manuals
Installation Instructions Formula A1/III-IV
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Front-terminal connection and 4P TMF release enable rapid, secure wiring and quick panel servicing, reducing installation time and field errors in control cabinets. This translates to lower labor costs and increased line availability in automotive, packaging, and process industries. Feature → 32 A main circuit rating with 690 V insulation supports common distribution needs while maintaining safety margins in medium-voltage switchgear; application spans transformers, generators, and motor control centers with compliant protection. Feature → High short-circuit performance Ics and Icu values deliver robust fault withstand across varying voltages, improving system resilience in data centers and factory floors that demand continuity. Feature → Mechanical durability (8500 cycles) and electrical durability (1500 cycles) lower maintenance intervals and extend service life, reducing lifecycle costs in continuous-process environments. Feature → RoHS, REACH, and TSCA compliance plus CE Conformity ensure regulatory readiness, simplifying procurement, cross-border sourcing, and supplier qualification for global projects. Feature → Compact footprint and standardized dimensions support retrofit and compatibility with existing ABB SACE FORMULA components, enabling scalable upgrades without major enclosure changes.
Get a Quick Quote for a ABB 1SDA068764R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA068764R1?
Enquire Now
FAQs
This unit uses front-terminal connections, which simplifies wiring and reduces cabinet depth. Ensure the panel offers accessible front terminals, compatible enclosure openings, and appropriate clearance for safe operation and maintenance. Refer to the Installation Instructions Formula A1/III-IV for step-by-step mounting and wiring guidance.
Key specs include 32 A rated current, 690 V rated insulation voltage, and a rated impulse withstand voltage of 6 kV. Short-circuit performance is rated up to 25 kA (at 240 V AC) and 100 kA (Icu) across specified voltages, with a 4P TMF release and front-terminal connection.
Yes. The 4P TMF 1SDA068764R1 is designed for transformer and generator protection within SACE FORMULA configurations, offering reliable protection with front-terminal accessibility and compatibility with common low-to-medium voltage panels used in power distribution and automation networks.
The device carries CE conformity (EC Declaration of Conformity), along with RoHS and REACH declarations, and TSCA compliance. WEEE categorization and ETIM classifications also align it with global regulatory and procurement requirements for industrial equipment.
With 8500 mechanical durability cycles and 1500 electrical durability cycles, the unit offers extended service life and reduced replacement frequency. Front-terminal design accelerates wiring and servicing, lowers labor costs, and minimizes downtime in high-throughput production lines.