ABB 1SDA069760R1 Moulded Case Circuit Breaker - UL

Part Number: 1SDA069760R1
Manufacturer
ABB
Part number
1SDA069760R1

Quick Summary

ABB 1SDA069760R1 is a moulded case circuit breaker for industrial power protection and distribution. Engineers often struggle with downtime caused by unreliable protection devices, manual rework, and difficult front-access servicing; this unit addresses those pain points through front terminals and a TMF release. With UL listing, CE declaration, and RoHS/REACH compliance, it supports global procurement, reduces regulatory risk, and simplifies supplier qualification across multinational projects. Designed for 3P protection in SACE Formula configurations, it delivers predictable coordination with downstream protection, minimizes panel space impact, and helps achieve faster commissioning and lower total cost of ownership. Its front-terminal design and compact footprint ease bolt-down in crowded panels and support upgrade paths for evolving automation architectures.

Product Information

Extended Description

1SDA069760R1 ABB: C.BREAKER FORMULA A1N 100 UL/CS A FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 70-700 A
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Environmental Information - Formula A1-A2 | Breakers - Packaging disposal information
Order Code US and Canada
A1N070TW
EAN
8015644705190
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
60 mm
Product Net Weight
0.75 kg
Package Level 1 Units
1 piece
Package Level 1 Width
136.5 mm
Package Level 1 Height
124 mm
Package Level 1 Depth / Length
110.5 mm
Package Level 1 Gross Weight
0.8 kg
Package Level 1 EAN
8015644705190
Product Main Type
SACE FORMULA
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Number of Poles
3P
Rated Current (In)
Main Circuit 70 A
Rated Impulse Withstand Voltage (Uimp)
6 kV
Rated Insulation Voltage (Ui)
690 V
Rated Operational Voltage
240 V AC | 250 V DC
Rated Uninterrupted Current (Iu)
100 A
Release
TMF
Release Type
TM
Short-Circuit Performance Level
N
Standards
UL
Sub-type
A1
Terminal Connection Type
Front
Interrupting Rating acc. to UL489
(240 V) 25 kA | (250 V DC) 2 Poles in Series 10 kA
Data Sheet, Technical Information
1SXU210022D0201
Declaration of Conformity - CE
EC Declaration of Conformity Formula DSA A1
Instructions and Manuals
Installation instructions FORMULA A1 III UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
3P protection with 70 A main current provides dependable safeguarding for motor feeders and transformer lines in industrial panels, aligning with ABB SACE protection schemes to minimize nuisance trips and protect critical loads. This reduces unplanned downtime and extends equipment life by ensuring selective, reliable tripping under fault conditions. Front-terminal connections simplify installation and field maintenance, enabling faster wiring, easier retrofits, and reduced chance of wiring errors in tight panel spaces. The TMF (Thermomagnetic) release delivers a robust thermal-magnetic trip characteristic suitable for general protection needs, supporting predictable coordination with upstream devices and enhancing panel reliability. Key electrical ratings include Ui 690 V, Uimp 6 kV, In 70 A and IU 100 A, with a 3P configuration that suits both feeder and protective applications in industrial environments. The device offers stout interrupting capability (UL489): up to 25 kA at 240 V AC and 10 kA at 250 V DC in two-pole series, enabling confident protection in demanding systems. RoHS and REACH declarations, CMRT reporting, and TSCA declarations provide regulatory assurance for global supply chains. The unit’s dimensions and weight—76.2 mm wide, 130 mm high, 60 mm deep, and 0.75 kg—coupled with front-terminal access, support compact, modular panel design and easier maintenance. Packaging and order information, including the US/Canada code A1N070TW and EAN 8015644705190, facilitate efficient procurement and logistics for electrical distributors and OEMs. Overall, this ABB SACE Formula component delivers reliable protection, straightforward installation, and a clear path to compliant, cost-effective automation upgrades.

Get a Quick Quote for a ABB 1SDA069760R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA069760R1? Enquire Now

FAQs

This 3P moulded case breaker uses front-terminal connections, enabling straightforward wiring in standard panel slots. For retrofit projects, verify panel cutout dimensions (76.2 mm width, 130 mm height, 60 mm depth) and ensure compatible busbar spacing. Use appropriate torque on terminals as per the installation instructions and confirm alignment with SACE Formula mounting provisions to maintain correct trip coordination.
Rated current In is 70 A, rated insulation Ui is 690 V, and rated impulse withstand Uimp is 6 kV. The device offers 3P protection with a nominal uninterrupted current IU of 100 A. Interrupting ratings per UL489 are up to 25 kA at 240 V AC and 10 kA at 250 V DC for two poles in series, enabling safe operation in demanding industrial circuits.
Yes. The Moulded Case Circuit Breaker supports transformer protection and motor feeder circuits within ABB SACE Formula A1 configurations. Its TMF release provides reliable thermal-magnetic tripping, enabling selective coordination with upstream devices and protecting critical loads with fast, predictable trips in distribution panels.
The unit carries UL listing, CE Declaration of Conformity, RoHS and REACH declarations, and CMRT documentation. TSCA compliance is provided as part of ABB’s environmental and regulatory reporting. These certifications facilitate global procurement and reduce regulatory risk for multinational projects.
Front-terminal design simplifies installation and reduces wiring errors, cutting commissioning time. Regular maintenance involves visual inspection, torque checks, and tripping test procedures per the installation manual. The combination of UL/CE compliance, compact footprint, and reliable TMF release helps reduce downtime and lifecycle costs, improving overall return on investment for control panels and power distribution networks.