ABB 1SDA074636R1 Moulded Case Circuit Breaker - UL/CSA

Part Number: 1SDA074636R1
Manufacturer
ABB
Part number
1SDA074636R1

Quick Summary

Moulded Case Circuit Breaker XT1N protects power distribution in industrial plants, delivering rapid short-circuit protection and reliable control. Engineers often contend with unexpected outages and the high cost of maintenance in modern switchgear, where accessibility and diagnostics are critical. This ABB device carries UL489 and CSA certifications, along with a CE Declaration of Conformity, supporting global compliance. With front-terminal access, a TMF thermomagnetic release, and a compact 3-pole footprint, it streamlines installation, reduces wiring complexity, and enhances safety in dense panel layouts. The combination of performance, compliance, and sustainability—highlighted by ABB EcoSolutions and robust environmental declarations—translates into lower downtime and a clearer path to regulatory adherence for your power distribution projects. Ideal for motor feeders, transformers, and distribution boards across manufacturing, data centers, and process industries.

Product Information

Extended Description

1SDA074636R1 ABB: C.BREAKER TMAX XT1N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 25-500 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1NU3025AFF000XXX
EAN
8015644785031
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644785031
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.0 W
Rated Current (In)
25 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
25 A
Short-Circuit Performance Level
N
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 50 kA | (480 V AC) 25 kA | (600Y / 347 V AC) 18 kA | (250 V DC) 2 Poles in Series 35 kA | (500 V DC) 4 Poles in Series Kind 35 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Three-pole XT1N with front-terminal connections and TMF release translates into faster wiring and safer operation. This design minimizes panel contamination and reduces assembly time, while the front-term arrangement simplifies inspection and testing during commissioning. Application: motor control centers and switchgear assemblies in harsh industrial environments benefit from easier installation and quicker fault isolation. The unit supports mixed networks with a rated voltage of 600Y/347 V AC and 500 V DC, enabling seamless integration into systems that use both AC and DC feeds, reducing inventory complexity and simplifying upgrades. With a 25 A nominal current and a 500 A instantaneous setting, it delivers selective protection for feeders and motors, limiting unnecessary trips and improving process uptime. Front terminals and bolted connections at 6 N·m tightening torque enable reliable field installation with repeatable contact pressure. Busbar compatibility of 45.5–80 mm² reduces wiring footprint while maintaining solid electrical performance. Electrical durability of up to 8000 cycles and mechanical durability up to 25000 cycles ensure long service life in demanding environments. Compliance features include UL489, CSA, RoHS, REACH, CMRT, and EPD declarations, supplemented by end-of-life disassembly instructions for responsible recycling. ABB EcoSolutions integration supports packaging disposal guidance and site-level waste reduction programs, contributing to lower total cost of ownership over the product lifecycle.

Get a Quick Quote for a ABB 1SDA074636R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074636R1? Enquire Now

FAQs

Install as a 3P front-terminal device with bolted terminals and 6 N·m tightening torque. Use busbar range 45.5–80 mm² and ensure secure mounting in a compatible panel. The front-terminal design simplifies wiring, inspection, and commissioning, while the TMF release requires standard maintenance access for testing of the thermomagnetic trip. Verify terminal polarity and verify conformity to UL489 and CSA CS22.2 standards during commissioning.
The 25 A rated current (In) defines normal operating current, while the 500 A rated instantaneous short-circuit setting (Ii) provides rapid tripping under fault conditions. This combination supports selective coordination with upstream devices, minimizing downtime and protecting feeders and motors without nuisance tripping under normal starting surges. Design your protection scheme to match circuit loads and fault current levels in the installation.
Yes, the XT1N is specified for AC and DC operation. Rated operational voltage is 600Y/347 V AC and 500 V DC, enabling use in mixed networks common in industrial automation. This versatility supports motor control centers and panel boards where both supply types are present, reducing the number of different devices required on site.
The device carries UL489 and CSA certifications, plus a CE Declaration of Conformity. Additional environmental declarations include RoHS, REACH, CMRT, and an Environmental Product Declaration (EPD) for Tmax XT. End-of-life disassembly guidance is provided to assist in recycling, contributing to regulatory adherence and sustainability programs across regions.
ROI benefits come from reduced downtime due to fast fault isolation (30 ms opening) and reliable front-terminal installation that speeds commissioning. Mechanical and electrical durability (up to 25000 and 8000 cycles respectively) lowers replacement frequency. Lifecycle support includes disassembly instructions and EPD/ RoHS compliance, which simplify maintenance planning, spare part management, and end-of-life recycling investments.