ABB 1SDA074644R1 Moulded Case Circuit Breaker - UL/CSA TMF

Part Number: 1SDA074644R1
Manufacturer
ABB
Part number
1SDA074644R1

Quick Summary

ABB 1SDA074644R1 Moulded Case Circuit Breaker provides reliable overload and short-circuit protection for industrial power distribution and machine control. Design teams often struggle with UL/CSA compliance while maintaining uptime under demanding 3-phase loads; this XT1N TMF device helps streamline validation and installation. Key certifications include UL489 and CSA listings with a CE declaration of conformity, supported by an Environmental Product Declaration (EPD) and recyclability data. The solution is designed for SACE Tmax XT systems, offering front-terminal accessibility and a practical tightening torque, delivering predictable performance in panel assemblies and field installations. This translates to measurable business value through improved safety, reduced downtime, and compliant, sustainable operations.

Product Information

Extended Description

1SDA074644R1 ABB: C.BREAKER TMAX XT1N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 80-800 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
a3092b52-c7b0-46f4-a587-9578e451bba7 Italy (IT)
Simplified SCIP
b2340d3b-188b-4daf-8947-8bb974b4f69e Germany (DE) | f78364e7-bd45-4331-9134-7d13a1e77777 Netherlands (NL) | 60947389-f3a5-4348-b36e-eb9c73fa6d0d Portugal (PT) | 17bda6c2-328a-4e8a-a4a1-742560832538 Norway (NO) | 58ee7ea9-978d-487d-ab1c-c7c30f13a173 Finland (FI) | adbffa6f-4548-4108-8885-289fe00fcb55 Poland (PL) | eca4e28b-3bb4-4748-8506-4a95a5f21ccd Netherlands (NL) | 47f5d8bc-8c12-47db-a29a-5c02bf51a3e4 Netherlands (NL) | 22133da5-b4fb-4ec8-b112-83d7d145d4f6 Estonia (EE) | 18ca1470-07ff-446e-9d02-a5b426685eb0 Germany (DE) | d6df0810-1652-49ce-8913-c4c7bf90ca3a Denmark (DK) | 76ee3543-11ee-4243-97d6-5daee2d350b7 Germany (DE) | 3f83c144-b5ff-40dd-bfa6-299f8e6b4dfd Croatia (HR) | 34dc34be-e7fb-4df6-82b6-b2c5278a31e1 Czech Republic (CZ) | 6a8f9c77-c878-4e35-befa-c304bcc097aa Poland (PL) | 4293d883-427d-4be4-a847-50dc2e10393e Greece (GR) | 7bfd3ed4-a382-4072-9a18-8ae4ddc193ca Bulgaria (BG) | a6a9fe1c-f309-4111-87a3-87d19d51e683 Sweden (SE) | 0379fd51-9eb7-4184-b8a2-1507a9ef780e Poland (PL) | 98fcf8d4-5d6a-4321-b91e-b2fa16ed54c3 France (FR) | ef35b0b4-7227-4c34-b530-51191eb159df Sweden (SE) | 1907a2c2-5b32-40e3-8c6c-d2155eb2e18b Germany (DE) | 9256e718-5baf-42cd-abcd-f1badeae94c4 Germany (DE) | 34ddc332-dd9c-4010-beb1-5d8a180222b7 France (FR) | a160dfe9-ac41-4c92-b55f-397bdac67266 Netherlands (NL) | 6b15499e-5f7b-43dd-83ca-7cc107a77823 Spain (ES) | bc7b4ecd-79e8-4c3e-b815-1a68bcf949f3 Netherlands (NL)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1NU3080AFF000XXX
EAN
8015644786212
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644786212
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.8 W
Rated Current (In)
80 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
900 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
80 A
Short-Circuit Performance Level
N
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 50 kA | (480 V AC) 25 kA | (600Y / 347 V AC) 18 kA | (250 V DC) 2 Poles in Series 35 kA | (500 V DC) 4 Poles in Series Kind 35 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Three-pole XT1N with TMF release delivers precise protection against overloads and short circuits, reducing the risk of equipment damage and unplanned downtime in heavy-duty machinery. Result: safer panels and fewer emergency interventions in manufacturing lines; Application: control cabinets powering motors and transformers. Feature → Business Impact → Application: Front-terminal bolt connection and 6 N·m tightening torque enable fast, reliable wiring in dense panel layouts, speeding installation and simplifying future maintenance; Application: industrial distribution boards with limited space. Feature → Business Impact → Application: Rated current of 80 A and 600Y/347 V operation supports a wide range of medium-scale drives while maintaining robust interrupting capability; Application: machine control panels and power distribution enclosures. Feature → Business Impact → Application: High instantaneous short-circuit setting (900 A) improves selectivity in feeders, minimizing fault scope and improving service continuity; Application: transformer and MCC protection schemes. Feature → Business Impact → Application: UL489 and CSA certifications with CE DoC, plus EPD and recyclability data, support regulatory compliance and sustainability reporting; Application: procurement cycles in regulated industries. Feature → Business Impact → Application: Clear wiring diagrams and documented mechanical drawings reduce commissioning errors and training time; Application: commissioning in panel builds and retrofit projects.

Get a Quick Quote for a ABB 1SDA074644R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074644R1? Enquire Now

FAQs

Install with front-terminal bolt connections and torque to 6 N·m per pole. Use busbars between 45.5 and 80 mm² and ensure the panel busbar layout accommodates 600Y/347 V systems. Align the device to the DIN rail or mounting frame as per the XT1 diagram, then verify correct phase connections and crowding. This minimizes wiring errors and facilitates future maintenance.
Key ratings include 80 A rated current, 600Y/347 V AC (and 500 V DC) operating voltage, 125 A rated uninterrupted current, and a 900 A rated instantaneous short-circuit setting. Interrupting ratings at UL489 are up to 50 kA at 240 V, 25 kA at 480 V, with appropriate ratings for higher DC configurations per model specs.
Yes. The device is UL489 listed and CSA certified (Intrinsic Safe variant available). It also carries a CE Declaration of Conformity for Tmax XT1 families, supported by environmental declarations and SCIP/CMRT data for responsible sourcing and end-of-life handling.
Front-terminal design simplifies wiring in compact switchgear and control panels, enabling straightforward terminal access. The recommended tightening torque is 6 N·m per bolt, ensuring a secure connection for reliable current transfer and consistent electrical performance under dynamic loads.
This XT1N TMF device supports a durable mechanical lifecycle (tens of thousands of operation cycles) and a robust electrical durability profile. With documented disassembly instructions and ECO/Sustainability data, maintenance planning benefits from predictable replacement intervals, reduced downtime, and alignment with end-of-life recycling targets in regulated industries.