ABB 1SDA074650R1 Moulded Case Circuit Breaker - UL/CSA

Part Number: 1SDA074650R1
Manufacturer
ABB
Part number
1SDA074650R1

Quick Summary

The Moulded Case Circuit Breaker protects electrical systems by interrupting fault currents in power distribution panels. It helps technicians minimize downtime and protect critical loads during short circuits or overloads. This XT1N device is UL489 and CSA CS22.2 certified, with a CE declaration and RoHS compliance to support global deployments. For panel builders and maintenance teams, the ability to mount front terminals with a 6 N·m tightening torque simplifies installation and service, while the 4-pole configuration and TMF release deliver reliable protection across a wide operating range. By selecting this field-proven MCCB, engineers reduce risk, improve compliance, and streamline procurement with a single product family like SACE Tmax XT.

Product Information

Extended Description

1SDA074650R1 ABB: C.BREAKER TMAX XT1N 125 UL/CSA FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 20-500 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1NU4020AFF000XXX
EAN
8015644786274
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8015644786274
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.8 W
Rated Current (In)
20 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
20 A
Short-Circuit Performance Level
N
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 50 kA | (480 V AC) 25 kA | (600Y / 347 V AC) 18 kA | (250 V DC) 2 Poles in Series 35 kA | (500 V DC) 4 Poles in Series Kind 35 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature is a 4-pole front-terminal TMF release. Business impact is precise trip control with fast disconnection, which reduces fault clearance time and limits fault propagation, improving system availability in manufacturing lines and data centers. Application centers on distribution boards and switchgear where reliable protection is essential. Feature is a rated current of 20 A with rated uninterrupted current (Iu) of 125 A. Business impact includes minimizing nuisance trips during routine operation and enabling sustained feeds to critical loads during maintenance, improving uptime and reducing maintenance costs. Application ranges from small feeders to subpanels in industrial facilities. Feature is rated operational voltage of 600Y/347 V AC and 500 V DC, enabling dual‑voltage installations. Business impact includes flexibility for mixed‑supply environments, simplifying design reviews and compliance checks. Application includes data centers, process lines, and panel assemblies with mixed DC and AC circuitry. Feature is a 4P configuration with front terminals and a tightening torque of 6 N·m. Business impact reduces risk of loose connections, improves vibration resistance, and speeds up installation in tight panels. Application suits control cabinets in Machinery, Automotive, and General Industry. Feature is UL489/CSA certification and DoC with RoHS support. Business impact ensures regulatory compliance and environmental stewardship, easing audits and supplier qualification. Application supports global projects requiring standardized MCCBs within the SACE Tmax XT family. Feature is compact XT1 footprint with dimensions 101.6 mm wide, 130 mm high, and 70 mm deep. Business impact streamlines panel layout, reduces space requirements, and simplifies retrofit projects. Application includes modern switchgear where space and serviceability matter.

Get a Quick Quote for a ABB 1SDA074650R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074650R1? Enquire Now

FAQs

ABB 1SDA074650R1 uses front-terminal bolt connections and a 6 N·m tightening torque, designed for easy, secure installation in cabinets and switchboards. Ensure the busbar width accommodates 45.5 to 80 mm² conductors and verify clearance for four-pole mounting. The compact XT1N footprint simplifies serviceability and replacement without disturbing adjacent components.
Key specs include 20 A nominal current, 125 A rated operational current (Iu), 600Y/347 V AC and 500 V DC ratings, four poles, TMF release, UL489 standard, and interrupting capacities up to 50 kA at 240 V, 25 kA at 480 V, with 18 kA at 600Y/347 V. It uses front-terminal connections for reliable fault interruption in mixed-voltage installations.
Yes. The four-pole TMF‑release MCCB provides selective protection for motor feeders and buses. The 20 A rating covers control circuits and downstream protections, while the Iu capability allows continued operation during maintenance. Its compatibility with the SACE Tmax XT family supports standardized motor protection across panels and upgrade projects.
The device carries UL489 and CSA CS22.2 listings, with a CE Declaration of Conformity and RoHS compliance. Documentation includes DoC and product data sheets, plus end-of-life, environmental, and recycling information. These certifications support compliance in global installations and supplier qualification programs.
The MCCB offers reduced downtime through reliable protection and fast serviceability, minimizing cascading faults. Front-terminal mounting speeds installation and retrofits, while standardization within the SACE Tmax XT family lowers inventory and training costs. Over the life of a facility, this translates to lower maintenance labor, shorter outages, and predictable procurement costs.