ABB 1SDA074657R1 Moulded Case Circuit Breaker - UL/CSA

Part Number: 1SDA074657R1
Manufacturer
ABB
Part number
1SDA074657R1

Quick Summary

ABB 1SDA074657R1 is a molded case circuit breaker for industrial power distribution in panels. Upgrading panels often poses space, accessibility, and regulatory compliance challenges that slow projects. This XT1 TMF unit carries UL489 and CSA certifications with a CE conformity declaration for broader market access. Its 4‑pole front-terminal design and compact 101.6 mm width enable fast installation and simpler servicing. Beyond protection, ABB EcoSolutions features support responsible end‑of‑life handling and a documented recyclability rate. Rated 60 A nominal current with a 700 A instantaneous setting and 600Y/347 V operation, it suits distributed energy, data centers, and machine builders.

Product Information

Extended Description

1SDA074657R1 ABB: C.BREAKER TMAX XT1N 125 UL/CSA FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 60-600 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
595a4e6f-ea98-49fe-8827-c2012ccc2707 Italy (IT)
Simplified SCIP
f6356f53-1c2e-481f-bfc0-bfbf8532bbfb Belgium (BE) | a776556c-9091-4b30-9519-8d3e1ec23b4e Estonia (EE) | 5a2dfe6c-aef2-4c78-ad9b-664d11afd1e9 Denmark (DK) | bfed5da3-b17e-44f2-b99a-6087a712123d Sweden (SE) | d9b25f46-3e77-4523-93bc-4c6581f1d7d9 Germany (DE) | 58a1f6c1-3c2a-4d8d-bbc3-59454e87a4fd Germany (DE) | 10ec52b2-f663-4a83-895c-d28d3ced1d1b France (FR) | c87be889-cde8-4b8a-a900-1f49248f1d7b Czech Republic (CZ) | 79a0b81a-cefb-4df5-aaa0-6ab0971d76d0 Germany (DE) | 61d8817a-9329-4ea7-9c03-190c0a3cbf0d Croatia (HR) | ae9458f9-9d69-4a52-b9ce-e650ff4cfdb0 Germany (DE) | 382135ff-ffc4-4b16-9e4d-a1da8c075e2c Spain (ES) | 2349ccfd-5984-421b-8e44-3681c274444b Hungary (HU) | db6c272d-18c5-4389-ab77-1f636bf08c3b Belgium (BE) | 001afc97-f792-4e90-8aa4-7a2c7bcbb6ec Germany (DE) | e7f1ad78-ec2e-4482-a610-0336603e0067 Portugal (PT) | df29a8dc-3d3e-46a6-aad9-6b3d0025e60b Norway (NO) | b3fc13ed-d4b1-4774-a646-3073a9941732 Sweden (SE) | 3166e432-d9b1-446f-9b5b-721281efa30b Bulgaria (BG) | cddfdec0-8108-482e-8f3d-6e8a84fe3785 Poland (PL) | 7063fcae-ed45-4fb0-9ac3-cecb977bf56c Poland (PL) | 98ba00b7-e3d8-496c-9a68-0629f002bf60 France (FR) | bca9bac0-3685-4513-9789-e63dda0ac21c Greece (GR) | 8a2faa4f-16e2-4141-9f23-b9ca52dcd07a Hungary (HU) | 4ef0f115-8534-487b-b80b-b86c08b56a5e Poland (PL) | b0f7fd5f-20cc-486f-901c-63f540a81b44 Netherlands (NL) | e1fc2e4b-512b-4650-93e7-d3ebbdad3023 Finland (FI)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1NU4060AFF000XXX
EAN
8015644786342
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8015644786342
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 3.9 W
Rated Current (In)
60 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
700 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
60 A
Short-Circuit Performance Level
N
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 50 kA | (480 V AC) 25 kA | (600Y / 347 V AC) 18 kA | (250 V DC) 2 Poles in Series 35 kA | (500 V DC) 4 Poles in Series Kind 35 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The 4‑pole XT1 frame with front terminals simplifies wiring and reduces installation time, boosting panel build efficiency and lowering labor costs on new builds and upgrades. Application: Power distribution panels in manufacturing lines and data centers benefit from quicker commissioning and easier maintenance. Feature → Business Impact → Application: TMF thermal-magnetic release provides selective tripping and reliable fault clearance, minimizing downtime and preventing collateral damage in critical systems. Application: Machine control panels and switchgear where uptime is essential. Feature → Business Impact → Application: rated current of 60 A with a 700 A short‑circuit setting delivers robust protection for medium‑sized distribution circuits while enabling safe coordination with upstream protection. Application: Industrial feeders and MCCs. Feature → Business Impact → Application: compact footprint (101.6 mm wide) and 1.4 kg weight save enclosure space and support retrofits in limited‑clearance installations. Application: Retrofit projects and compact control cabinets. Feature → Business Impact → Application: front connections and M6 screw compatibility reduce wiring complexity and help installers achieve reliable conductor termination. Application: Panel upgrades and serviceability. Feature → Business Impact → Application: RoHS, REACH, and EPD disclosures validate sustainability commitments and regulatory alignment. Application: Compliance‑driven design and procurement programs. Feature → Business Impact → Application: 50 kA to 35 kA interrupting ratings across voltages demonstrate strong fault protection across AC/DC profiles. Application: Industrial VFD feeds, transformers, and generation equipment.

Get a Quick Quote for a ABB 1SDA074657R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074657R1? Enquire Now

FAQs

The unit is a front‑terminal, 4P XT1 molded case circuit breaker designed for bolt‑type terminals and M6 main circuit connections. It fits standard panels and busbar ranges from 45.5 to 80 mm², with dimensions of 101.6 mm width, 130 mm height, and 70 mm depth, enabling straightforward retrofits and service access.
Rated current is 60 A with an instantaneous setting up to 700 A. Operating voltage is 600Y/347 V AC (and 500 V DC). Interrupting ratings (UL489) vary by voltage: up to 50 kA at 240 V AC, 25 kA at 480 V AC, and 18 kA at 600Y/347 V AC, with 35 kA for 2 or 4 poles in series on DC scenarios.
Key certifications include UL489 for molded case breakers, CSA certification (intrinsic safe reference 9AKK10103A3905), and a CE Declaration of Conformity. The product also aligns with RoHS/REACH requirements, End‑of‑Life disassembly guidance, and environmental declarations (EPD) for Tmax XT series.
This 4P XT1 TMF model is well suited for power distribution panels in manufacturing lines, machine control cabinets, data centers, and other industrial facilities needing reliable short‑circuit protection, easy maintenance, and compliant lifecycle management. Its front‑terminal design supports quick panel upgrades and orderly wiring in constrained enclosures.
Electrical durability is rated at up to 8000 cycles per hour and 125 A uninterrupted current, with mechanical durability up to 25000 cycles. The unit’s RoHS/REACH compliance, documented end‑of‑life instructions, and ECO‑Solutions framing support easier servicing, recycling, and reduced total cost of ownership over the product lifecycle.