Moulded Case Circuit Breaker protects electrical circuits in industrial power distribution, isolating faults quickly and safely in demanding plants. Engineers often face downtime and commissioning delays when selecting protection that fits limited panel space and wiring requirements. This model aligns with UL489 and CSA CS22.2 standards, carries a CE declaration, and supports RoHS/REACH environmental compliance for modern grids. Its compact XT Tmax XT design with front-terminal access streamlines installation, while robust TMF release enhances fault protection, helping operations reduce unplanned outages and maintenance complexity. For panel builders and maintenance teams, this device provides reliable protection without sacrificing accessibility or serviceability, delivering measurable efficiency and compliance advantages across critical applications.
Product Information
Extended Description
1SDA074667R1 ABB: C.BREAKER TMAX XT1S 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 30-500 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1SU3030AFF000XXX
EAN
8015644786441
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644786441
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.8 W
Rated Current (In)
30 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
30 A
Short-Circuit Performance Level
S
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA | (480 V AC) 35 kA | (600Y / 347 V AC) 22 kA | (250 V DC) 2 Poles in Series 42 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Front-terminal, 3-pole fixed design enables rapid, error-free wiring and simplified panel integration, reducing install time and field wiring errors. Feature → Business Impact → Application: Faster panel assembly translates to lower labor costs and shorter commissioning windows in manufacturing lines and distribution boards. The TMF thermomagnetic release with a 30 A setting range offers precise protection while supporting an uninterrupted current (Iu) of 125 A; the 500 A short-circuit instantaneous rating (Ii) enhances safety in fault events, minimizing equipment damage in motor control centers and process skids. Feature → Business Impact → Application: Clear protection levels improve downtime resilience and meet electrical safety standards for heavy industry. With a rated voltage of 600Y/347 V AC and 500 V DC, the breaker supports mixed voltage systems common in modern plants, reducing the need for multiple devices. Feature → Business Impact → Application: Standardized protection across AC/DC networks enables easier maintenance and spare parts planning. Power loss of 1.8 W per pole contributes to cooler panels and lower energy draw on large installations. Feature → Business Impact → Application: Energy efficiency and thermal stability in compact switchgear. The device complies with UL489 and CSA CS22.2 standards, CE conformity, RoHS, and REACH, supported by disassembly instructions and an Environmental Product Declaration, enabling easier end-of-life handling and sustainability reporting. Feature → Business Impact → Application: Meets corporate ESG goals while simplifying regulatory documentation for audits. Additional installation advantages include a tightening torque of 6 N·m and front-terminal connection type for straightforward maintenance, plus a busbar connection range of 45.5 to 80 mm², facilitating versatile integration with common MCC layouts and minimizing rework during retrofits. Feature → Business Impact → Application: Reduced maintenance cycles, faster replacements, and adaptable integration in power distribution and transformer/tap installations.
Get a Quick Quote for a ABB 1SDA074667R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA074667R1?
Enquire Now
FAQs
Mounting is straightforward with the front-terminal design. Align the breaker to the panel interface, tighten each terminal to 6 N·m as specified, and connect the busbar within the 45.5 to 80 mm² range. This layout enables quick wiring, minimizes crosstalk, and supports fast field servicing without rear wiring complexity.
Key ratings include 30 A rated current (In), 600Y/347 V AC and 500 V DC operating voltages, and 125 A rated uninterrupted current (Iu). The instantaneous short-circuit setting (Ii) is 500 A. Interruption performance follows UL489 with specified ratings for various voltages, ensuring robust protection in typical distribution and MCC installations.
Yes. The device supports DC operation up to 500 V DC and AC/DC current types, making it suitable for mixed voltage deployments in industrial plants, panels, and process lines requiring reliable DC protection alongside AC power circuits.
The unit is UL489-listed with a UL certificate (1SDL000163R0111), CSA-certified (Intrinsic Safe), and CE-declared. It also complies with RoHS and REACH, and ABB provides environmental data such as EPDs and disassembly guidance for end-of-life handling.
Front-terminal access speeds wiring and service tasks, while a 6 N·m tightening torque standardizes installation across teams. The 30 ms opening time, TMF release, and 3P configuration minimize downtime during protection events and simplify maintenance planning, supported by installation manuals and EcoSolutions documentation.