ABB 1SDA074669R1 Moulded Case Circuit Breaker - UL/CSA
Part Number: 1SDA074669R1
Quick Summary
ABB 1SDA074669R1 Moulded Case Circuit Breaker is a compact protection device for 3-phase power distribution in industrial control panels. Engineers often struggle with space constraints, nuisance trips, and complex wiring in switchgear enclosures. This XT1S based solution delivers UL489/CSA compliant protection with a TMF electro-mechanical release, front-terminal accessibility, and robust performance in demanding environments. It aligns with SACE Tmax XT ecosystems while supporting RoHS, REACH, and EPD commitments, helping you streamline procurement, compliance reporting, and end-of-life planning. By combining reliable protection with installation efficiency, it reduces panel footprint and commissioning time, delivering tangible cost savings without compromising safety or reliability.
Product Information
Extended Description
1SDA074669R1 ABB: C.BREAKER TMAX XT1S 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 40-500 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1SU3040AFF000XXX
EAN
8015644786465
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644786465
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.6 W
Rated Current (In)
40 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
40 A
Short-Circuit Performance Level
S
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA | (480 V AC) 35 kA | (600Y / 347 V AC) 22 kA | (250 V DC) 2 Poles in Series 42 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
The 3-pole XT1S design with fixed front terminals and a TMF release enables fast, error-free wiring and straightforward front-access maintenance, reducing installation time in control cabinets and MCCs. This feature translates into measurable business impact by shortening commissioning windows and lowering labor costs, while improving panel density for compact industrial layouts. The device’s 40 A rated current and 600Y/347 V AC (600Y/347 V) operating voltage ensure appropriate protection for medium-duty power distribution, transformers, and motor circuits, delivering safer startup and reduced fault propagation. Its 125 A rated uninterrupted current (Iu) and 500 A instantaneous setting (Ii) support reliable short-circuit response in demanding applications, with a 3P configuration optimized for balanced fault handling. The TMF release with a 40 A setting range provides precise protection against overloads and DC bus transients, improving uptime and service life for critical automation lines. Construction with front terminals and 6 N·m tightening torque simplifies wiring verification and reduces vibration-related loosening in harsh environments. Electrical durability (120 cycles/hour, 8000 cycles) and mechanical durability (240 cycles/hour, 25000 cycles) translate into long service life and lower maintenance costs in high-usage panels. The unit’s RoHS, REACH, CMRT, TSCA compliance, plus EPD and end-of-life disassembly guidance, supports responsible procurement and regulatory reporting across global operations. Compatibility with SACE Tmax XT and the product family ensures standardized protection schemes, while the option for 1 piece minimum order and front-terminal wiring enhances stocking, installation speed, and serviceability in panel shops.
Get a Quick Quote for a ABB 1SDA074669R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA074669R1?
Enquire Now
FAQs
This unit uses front terminals with M6 mounting screws and a tightening torque of 6 N·m. Plan for 70 mm depth clearance, ensure busbar connections are within 45.5–80 mm², and verify the 40 A setting range is configured to the protection target. Use standard MCC wiring practices to minimize heat buildup and ensure compliance with UL489 wiring requirements.
Key specs include a rated current of 40 A, rated operating voltage of 600Y/347 V AC and 500 V DC, and a 125 A rated uninterrupted current with a 500 A instantaneous setting. The device provides front-terminal access, 3P configuration, and a TMF release to meet UL489/CSA protection criteria for medium-duty distribution and transformer protection in industrial panels.
Yes. The 3P XT1S molded case breaker with high interrupting capability and TMF release is designed to protect power distribution networks, MCCs, and transformer feeders. Its front-terminal design simplifies wiring in compact panels, while its rugged construction supports reliable protection in steady-state and transient conditions typical of transformer feeders.
The unit aligns with UL489 and CSA standards, carries a CE Declaration of Conformity for Tmax XT1, and has associated UL and CSA documentation. It also notes RoHS and REACH compliance, CMRT for conflict minerals, TSCA declaration, an Environmental Product Declaration (EPD) for Tmax XT XT1, and end-of-life instructions.
With electrical durability of up to 8000 cycles per pole and mechanical durability up to 25000 cycles, maintenance intervals are extended and downtime is reduced. Front-terminal wiring speeds up installation and future swaps, while reliable UL/CSA compliance minimizes regulatory risk. The unit’s low power loss (2.6 W per pole) also contributes to energy efficiency in continuous operation scenarios.