ABB 1SDA074672R1 XT1S TMF 60-600 A 3P - UL/CSA
Part Number: 1SDA074672R1
Quick Summary
ABB SACE Tmax XT 1SDA074672R1 provides reliable three-pole circuit protection for industrial power distribution panels. In modern facilities, cramped spaces and high fault currents demand fast, dependable protection with simple installation. This device helps engineers reduce downtime through front-terminal mounting and clear signaling of trip events, even in demanding environments. ABB EcoSolutions underpin the product with an End Of Life disassembly guide, an Environmental Product Declaration, and recyclability targets aligned to EN45555, supporting sustainable design. With UL489/CSA ratings, CE conformity, and RoHS/REACH compliance, you gain verified safety and regulatory assurance across procurement and maintenance. Using this breaker can lower total cost of ownership by improving reliability, simplifying service, and speeding panel commissioning.
Product Information
Extended Description
1SDA074672R1 ABB: C.BREAKER TMAX XT1S 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 60-600 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1SU3060AFF000XXX
EAN
8015644786496
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644786496
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 3.9 W
Rated Current (In)
60 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
700 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
60 A
Short-Circuit Performance Level
S
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA | (480 V AC) 35 kA | (600Y / 347 V AC) 22 kA | (250 V DC) 2 Poles in Series 42 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application. Front-terminal, fixed mounting simplifies installation and reduces wiring errors, enabling faster panel assembly and safer service connections in crowded electrical rooms. This directly improves commissioning times and lowers field labor costs when retrofitting or expanding power distribution. Feature → 60 A rated current and 600Y/347 V rated operational voltage provide precise protection for distribution feeders and transformer feeds, minimizing nuisance trips while allowing predictable load management in manufacturing lines and data centers. Feature → TMF release with 3P protection and a 30 ms opening time delivers rapid fault interruption, reducing arc exposure and equipment damage in motors and transformers. Feature → 3.9 W power loss per pole enhances energy efficiency, supporting cooler enclosures and longer component life in continuous-duty applications. Feature → Front-terminal bolts with a 6 N·m tightening torque supported by M6 screwdriver guidance enable reliable, repeatable installation in field or panel fabrication environments. Feature → Compliance data including UL489 standards, RoHS/REACH declarations, and an EPD edge give procurement teams confidence in regulatory fulfillment and sustainable design targets, while the SACE Tmax XT family offers scalable protection as plants grow. Feature → Dimensions of 76.2 mm width, 130 mm height, and 70 mm depth ensure compatibility with standard enclosures and retrofit spaces, helping maintain uniform panel layouts and reducing rework during upgrades. Feature → 1.1 kg unit weight and 125 A uninterrupted current (Iu) support manageable heat and space planning in compact switchgear. Feature → Disassembly instructions and end-of-life data assist maintenance teams in compliant recycling workflows and eco-friendly end-of-life planning.
Get a Quick Quote for a ABB 1SDA074672R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA074672R1?
Enquire Now
FAQs
Yes. The XT1S uses front-terminal connections with a 6 N·m tightening torque and supports busbar cross-sections from 45.5 to 80 mm². It is designed for quick, reliable mounting in standard panels and uses a recommended Main Circuit M6 screwdriver. This simplifies field wiring and minimizes commissioning time while maintaining solid electrical integrity.
The device delivers UL489 ratings with a 3-pole configuration, Iu of 125 A, Ii of 700 A, and interrupting capabilities suitable for 240 V, 480 V, and 600Y/347 V AC as specified. It also supports 2-pole in series for certain DC configurations (as tested). This provides robust fault protection for feeders and transformer circuits in industrial installations.
Yes. With a fixed three-pole design, TMF release, and a 60 A nominal rating, it is well-suited for motor control centers and transformer feeders. The front-terminal design supports rapid servicing, while the 30 ms opening time minimizes arc energy during faults, protecting both equipment and personnel in critical power distribution paths.
The unit carries UL489/CSA compliant ratings, a CE Declaration of Conformity, and an Environmental Product Declaration (EPD) under ABB EcoSolutions. Additional RoHS and REACH compliance, CMRT for conflict minerals, and WEEE-related disposal guidance are provided to support regulatory adherence and sustainable end-of-life planning.
The 1SDA074672R1 offers predictable protection with low power loss (3.9 W per pole) and durable mechanical cycling (up to 25,000 cycles). Front-terminal installation reduces wiring time, while IEC/UL compliance minimizes rework during audits. Over time, this translates to lower downtime, faster panel upgrades, and improved lifecycle cost of ownership.