ABB 1SDA074674R1 Moulded Case Circuit Breaker - UL/CSA
Part Number: 1SDA074674R1
Quick Summary
ABB 1SDA074674R1 is a SACE Tmax XT1 molded case circuit breaker for industrial power distribution protection. Engineered to prevent nuisance trips and downtime in demanding electrical rooms, it delivers precise protection and simple maintenance. UL/CSA approvals, CE conformity and RoHS compliance help you meet regulatory requirements and streamline worldwide sourcing. As part of the SACE Tmax XT family, it simplifies upgrades and maintenance planning while delivering safer, more efficient main protection. This unit supports front-terminal installation and a robust 6 N·m tightening torque, speeding panel assembly. With 80 A rated current and 600Y/347 V ratings, it fits a wide range of air, water, and factory power networks.
Product Information
Extended Description
1SDA074674R1 ABB: C.BREAKER TMAX XT1S 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 80-800 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1SU3080AFF000XXX
EAN
8015644786519
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644786519
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.8 W
Rated Current (In)
80 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
900 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
80 A
Short-Circuit Performance Level
S
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA | (480 V AC) 35 kA | (600Y / 347 V AC) 22 kA | (250 V DC) 2 Poles in Series 42 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Thermomagnetic TMF release and fixed three-pole front-terminal design deliver selective protection and reduced nuisance trips, improving line reliability and uptime across critical production lines. Business Impact → Faster fault discrimination minimizes downtime and repair costs; Application → Ideal for control panels and distribution boards in manufacturing facilities. Feature → 80 A rated current with a defined 80 A setting range supports precise coordination with upstream protection, reducing oversizing and spare parts inventory. Business Impact → Lower lifecycle cost and simpler maintenance planning; Application → Main feeders and sub-feed circuits in medium-size plant facilities. Feature → Comprehensive compliance suite including UL489, CE, RoHS, and CMRT alongside EPD data ensures market readiness and sustainability. Business Impact → Regulator-friendly procurement and lower risk of non-conformance; Application → Global deployments with consistent documentation. Feature → Front-terminal, bolt-type connections with 6 N·m tightening torque enable quick, secure installations. Business Impact → Faster commissioning and stronger panel integrity; Application → New builds and retrofit projects in challenging environments. Feature → Detailed electrical ratings: 3P, 600Y/347 V AC, 125 A interrupting capabilities per UL/CSA, and 65 kA at 240 V AC. Business Impact → High fault tolerance and minimal system disruption; Application → Power distribution and motor control centers in high-demand settings. Feature → Compact footprint (76.2 mm width, 130 mm height, 70 mm depth) with 1.1 kg weight ensures easy panel integration. Business Impact → Saves space in crowded switchboards and simplifies replacement cycles; Application → Retrofit or upgrade in existing enclosures.
Get a Quick Quote for a ABB 1SDA074674R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA074674R1?
Enquire Now
FAQs
Yes. The XT1 fixed-front-terminal design accepts busbars up to 80 mm² and requires a tightening torque of 6 N·m using an M6 screwdriver. Its dimensions (76.2 mm wide, 130 mm high, 70 mm deep) fit standard distribution boards, allowing straightforward retrofits or new panel installs with predictable mounting footprints.
It is a 3P MCCB with an 80 A rated current, 600Y/347 V AC rating, and TMF release. Its UL489 compatibility supports interrupting ratings up to 65 kA at 240 V AC and 22 kA at 600Y/347 V AC, providing robust protection for demanding industrial feeders and motor circuits.
Yes. The device is UL/CSA approved and CE certified, with RoHS and CMRT support. This combination enables compliant deployment across North American and European facilities, simplifying procurement, sourcing, and cross-border installation for multi-site operations.
It carries UL489 and CSA certifications, CE declaration, RoHS compliance, CMRT, and an EPD for Tmax XT. These declarations support sustainable product stewardship and regulatory compliance, reducing risks in audits and product lifecycle management.
The unit reduces downtime through reliable TMF protection and precise trip settings, lowers spare parts needs with a clear setting range, and simplifies installation with front-terminal design and documented specifications. Over the lifecycle, this translates to faster maintenance cycles, lower labor costs, and improved plant availability.