ABB 1SDA074677R1 Moulded Case Circuit Breaker - UL/CSA

Part Number: 1SDA074677R1
Manufacturer
ABB
Part number
1SDA074677R1

Quick Summary

ABB 1SDA074677R1 Moulded Case Circuit Breaker is a three‑pole protection device that delivers reliable overcurrent protection for industrial power distribution. It is designed for front-terminal installation in panel boards and automation cabinets, simplifying wiring and serviceability in busy environments. Engineers often struggle with devices that slow commissioning or complicate testing; this model addresses those challenges with a compact XT1S form factor and TMF thermomagnetic release. Key certifications include UL489 and CSA CS22.2 with CE conformity, plus RoHS and CMRT lineage for regulatory comfort. The result is a robust, ecosystem‑friendly MCCB that supports SACE Tmax XT deployments while delivering predictable lifecycle performance and lower total cost of ownership.

Product Information

Extended Description

1SDA074677R1 ABB: C.BREAKER TMAX XT1S 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 110-1100 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1SU3110AFF000XXX
EAN
8015644786540
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644786540
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 8.3 W
Rated Current (In)
110 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
1250 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
110 A
Short-Circuit Performance Level
S
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA | (480 V AC) 35 kA | (600Y / 347 V AC) 22 kA | (250 V DC) 2 Poles in Series 42 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Three‑pole XT1 architecture with TMF release and front terminals → Business Impact: Fast fault clearance and easy wiring in crowded panels → Application: Control rooms, switchgear, and motor control centers. Feature: Rated current 110 A and rated voltage 600Y/347 V AC | 500 V DC → Business Impact: Cross‑domain applicability across AC and DC circuits, reducing part diversity → Application: Drive circuits, transformers, and distribution panels. Feature: Front terminal connections with 6 N·m tightening torque and busbar range 45.5–80 mm² → Business Impact: Secure, repeatable terminations minimizing heat and arcing → Application: OEM panel builds and retrofit projects. Feature: High UL489/CSA fault‑current ratings (up to 65 kA at 240 V, 35 kA at 480 V, 22 kA at 600Y/347 V) → Business Impact: Enhanced protection for critical loads and business continuity → Application: Data centers, processing lines, and town‑grid feeders. Feature: Disassembly and recycling alignment with ABB EcoSolutions (EPD, 55.9% recyclability) → Business Impact: Lower environmental footprint and easier end‑of‑life management → Application: Eco‑aware manufacturing lines and refurbished installs. Feature: Compact footprint and lightweight design (76.2 mm width, 1.1 kg) → Business Impact: Reduced panel real estate and logistics costs → Application: Space‑constrained control panels and modular assemblies. Feature: Regulatory and maker‑level support (UL/CSA, CE DoC, RoHS, CMRT) → Business Impact: Simplified procurement, faster compliance checks, and fewer audit findings → Application: Global deployments in automotive, process, and power industries.

Get a Quick Quote for a ABB 1SDA074677R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074677R1? Enquire Now

FAQs

This MCCB uses front terminals with a 6 N·m tightening torque and supports busbar connections from 45.5 to 80 mm², enabling straightforward wiring in panel boards and control cabinets and facilitating quick replacements without extensive rework.
Rated current is 110 A, with rated voltage of 600Y/347 V AC and 500 V DC. It provides a 1250 A short‑circuit instantaneous setting and UL/CSA interrupting ratings up to 65 kA at 240 V, ensuring robust protection for critical loads.
Yes. It is part of the SACE Tmax XT family, featuring TMF release and XT1 form factor with front terminals, making it a natural fit for Tmax XT installations and ecosystem compatibility in automation and power distribution.
It carries UL489 and CSA CS22.2 certifications, a CE Declaration of Conformity, RoHS compliance, and CMRT data, plus ABB EcoSolutions documentation for end‑of‑life and recycling guidance.
Electrical durability is rated at 8000 cycles and mechanical durability at 25000 cycles, with a power loss of 8.3 W per pole under rated conditions. These specs support predictable maintenance schedules and improved panel uptime, contributing to lower lifecycle costs.