ABB 1SDA074680R1 Moulded Case Circuit Breaker - UL/CSA

Part Number: 1SDA074680R1
Manufacturer
ABB
Part number
1SDA074680R1

Quick Summary

ABB 1SDA074680R1 Moulded Case Circuit Breaker provides reliable overcurrent protection for low-voltage distribution panels. Engineers often face challenges with limited front-terminal access, precise TMF release coordination, and complex wiring in control panels. This XT1S four-pole breaker is designed to simplify installation while meeting demanding safety standards, reducing commissioning time and potential human error. The device carries UL489 and CSA certifications, a CE Declaration of Conformity, and RoHS/REACH compliance, with additional environmental disclosures such as EPDs and recyclability data. As part of ABB EcoSolutions and the SACE Tmax XT family, it delivers robust protection with a clear business case for panel builders and maintenance teams alike.

Product Information

Extended Description

1SDA074680R1 ABB: C.BREAKER TMAX XT1S 125 UL/CSA FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 20-500 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1SU4020AFF000XXX
EAN
8015644786571
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8015644786571
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.8 W
Rated Current (In)
20 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
20 A
Short-Circuit Performance Level
S
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA | (480 V AC) 35 kA | (600Y / 347 V AC) 22 kA | (250 V DC) 2 Poles in Series 42 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Fixed front-terminal four-pole design simplifies wiring and reduces panel depth, enabling faster assembly and easier maintenance in switchgear upgrades and new panel builds, especially in 600Y/347 V AC environments. This aligns with 20 A nominal current and 125 A rated uninterrupted current, delivering predictable protection for feeders and transformers in commercial and industrial installations. Feature → Business Impact → Application: TMF release with a 30 ms SOR/UVR opening profile supports fast clearing of faults, minimizing arc exposure and downtime in critical processes such as HVAC, water treatment, and manufacturing lines. Feature → Business Impact → Application: UL489/CSA certification and IEC/UL compliance reduce regulatory risk for assemblies, enabling easier customer approval and market access in North America and international projects. Feature → Business Impact → Application: Front-terminal bolt connections with 6 N·m tightening torque provide secure terminations even in crowded enclosures, improving reliability and reducing rework on site for panel manufacturers and retrofit projects. Feature → Business Impact → Application: Rated voltage of 600Y/347 V AC and 500 V DC supports mixed AC/DC distribution schemes, offering flexibility for feeder protection in mixed-power facilities and automation panels. Feature → Business Impact → Application: Energy-conscious design with 1.8 W per pole power loss at rated conditions supports cooler enclosures and lower total cost of ownership in high-density control rooms. Feature → Business Impact → Application: Disassembly instructions and End Of Life guidance (Tmax XT XT1) assist with efficient recycling and responsible waste management, aligning with sustainability targets across automotive, process, and industrial settings. Feature → Business Impact → Application: EPD and recyclability data (55.9% design for resource loops) provide quantifiable environmental performance for ESG reporting and supplier assessments in capital projects and fleet upgrades.

Get a Quick Quote for a ABB 1SDA074680R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074680R1? Enquire Now

FAQs

The device uses front terminals with bolt connections and a tightening torque of 6 N·m, designed for secure front-entry wiring. It supports busbar connections from 45.5 to 80 mm² and is compatible with 4P configurations in fixed front-terminal layouts, making it suitable for compact panels and retrofit projects.
Rated current is 20 A with a rated operational voltage of 600Y/347 V AC and 500 V DC. It provides an uninterrupted current rating of 125 A, a rated instantaneous setting of 500 A, and an interrupting rating per UL489 up to 65 kA at 240 V, 35 kA at 480 V, and 22 kA at 600Y/347 V AC. It also supports 4P configurations and TMF release.
Yes. With 4P fixed front terminals and TMF release, the XT1S is designed for transformer protection in industrial power distribution. Its TM release and front-access design streamline installation and coordination in transformer feed panels, while UL489/CSA compliance ensures reliable protection in critical power systems.
This MCCB carries UL489 and CSA certifications, a CE Declaration of Conformity, RoHS and REACH declarations, and CMRT. It also aligns with ABB EcoSolutions and provides environmental data such as EPD for Tmax XT XT1 and a recyclability rate of 55.9% per EN45555, supporting sustainability reporting.
Expect reduced downtime from fast fault clearing (30 ms TMF/UVR opening), secure front-terminals for reliable terminations, and lower maintenance due to standardized SACE Tmax XT components. Energy losses are minimized (1.8 W per pole under load), contributing to lower operating costs over the panel’s life and improved overall uptime.