ABB 1SDA074681R1 Moulded Case Circuit Breaker - UL/CSA

Part Number: 1SDA074681R1
Manufacturer
ABB
Part number
1SDA074681R1

Quick Summary

The ABB 1SDA074681R1 Moulded Case Circuit Breaker protects industrial electrical power distribution. Engineers and procurement teams often face costly downtime caused by nuisance trips and difficult installations. This device carries UL489 and CSA certifications with a CE Declaration of Conformity, plus RoHS and REACH compliance for modern sustainable plants. Designed for front-terminal mounting and a four-pole XT1 configuration, it simplifies wiring, inspection, and service while meeting demanding safety standards. With SACE Tmax XT compatibility, reliable protection, and EcoSolutions backing, it supports reduced maintenance costs and faster project delivery.

Product Information

Extended Description

1SDA074681R1 ABB: C.BREAKER TMAX XT1S 125 UL/CSA FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 25-500 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1SU4025AFF000XXX
EAN
8015644786588
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8015644786588
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.0 W
Rated Current (In)
25 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
25 A
Short-Circuit Performance Level
S
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA | (480 V AC) 35 kA | (600Y / 347 V AC) 22 kA | (250 V DC) 2 Poles in Series 42 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Four-pole XT1 design with TMF release and front terminals delivers robust phase protection while simplifying wiring and service access. The four-pole configuration ensures coordinated protection across all three phases and neutral where applicable, reducing false trips and improving selectivity in motor and distribution panels. This makes it ideal for machine control cabinets and industrial switchgear where space is at a premium. Front-terminal bolt connections and a defined tightening torque of 6 N·m provide secure, vibration-tolerant terminations during commissioning and maintenance. Quick and reliable connections support faster assembly, lower error rates during wiring, and easier retrofits in existing panels using the XT1 family. This translates to lower commissioning time and improved field reliability. Rated current is 25 A with a rated operational voltage of 600Y/347 V and 500 V DC, ensuring safe operation across AC and DC bus configurations. This compatibility enables use in mixed-power environments common in industrial facilities and automation lines, reducing the number of SKUs required for different installations. High short-circuit interrupting ratings per UL489—65 kA at 240 V, 35 kA at 480 V, and 22 kA at 600Y/347 V—plus DC ratings (2P in series 42 kA, 4P in series 50 kA) provide strong protection against faults. This improves system uptime, minimizes damage during faults, and supports compliance with demanding electrical standards. EcoSolutions and environmental data—EPD, recyclability 55.9% per EN45555, disassembly instructions for Tmax XT XT1—back up sustainability goals. The device also uses RoHS/REACH-compliant materials and packaging disposal guidance, helping you meet corporate responsibility targets while maintaining performance. Ultra-compact dimensions and a front-terminal, bolt-based design support easy installation in crowded panels, with suitable busbar connection (45.5 to 80 mm²) and recommended screwdriver (Main Circuit M6) ensuring correct assembly. In addition, standard data sheets, WIRING diagrams, and installation instructions are readily available to reduce risk during upgrade projects.

Get a Quick Quote for a ABB 1SDA074681R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074681R1? Enquire Now

FAQs

Use the front-terminal bolt connections and tighten to 6 N·m per pole. Connect to busbars within 45.5 to 80 mm², using the Main Circuit M6 screwdriver for proper engagement. Verify polarity and torque at each connection, then perform a functional check to confirm correct operation and trip settings before commissioning.
Rated current is 25 A, rated operational voltage is 600Y/347 V, with 500 V DC capability. It supports four poles (4P), has front-terminal connections, and offers a TMF release. Short-circuit ratings per UL489 are up to 65 kA at 240 V and 22 kA at 600Y/347 V AC, with DC ratings in series up to 50 kA for 4P configurations.
Yes. The product carries UL489 protection and CSA certification (UL certificate 1SDL000163R0111; CSA 9AKK10103A3905) and is accompanied by a CE Declaration of Conformity. REACH and RoHS declarations are provided, aligning with modern regulatory requirements for safe, compliant electrical protection.
Suitable for industrial power distribution panels, machine control cabinets, and mixed AC/DC bus environments (600Y/347 V AC, 500 V DC). Front-terminals simplify retrofits and maintenance in crowded panels, while the 4P XT1 configuration supports reliable protection in multi-phase systems common in manufacturing plants and data centers.
ABB EcoSolutions framework applies, with an EPD for Tmax XT XT1, a recyclability rate of 55.9% per EN45555, and disassembly instructions for Tmax XT XT1. RoHS/REACH compliance and packaging disposal guidance support corporate ESG targets while maintaining electrical performance and safety.