ABB 1SDA074683R1 is a high-reliability moulded case circuit breaker for low-voltage protection in industrial power distribution. Engineers face downtime and fault-finding challenges; this XT1S-based device delivers fast fault isolation and clear signaling to minimize unplanned outages. It carries UL489, CSA, CE declarations, RoHS and REACH compliance to support global projects and supplier audits. Designed to integrate with the SACE Tmax XT family and front-terminal busbar systems, it reduces installation time while delivering consistent, dependable protection for critical machinery and panels. The equipment-level benefits translate into lower total cost of ownership and improved system uptime for industrial automation environments.

Product Information

Extended Description

1SDA074683R1 ABB: C.BREAKER TMAX XT1S 125 UL/CSA FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 35-500 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1SU4035AFF000XXX
EAN
8015644786601
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8015644786601
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2 W
Rated Current (In)
35 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
35 A
Short-Circuit Performance Level
S
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA | (480 V AC) 35 kA | (600Y / 347 V AC) 22 kA | (250 V DC) 2 Poles in Series 42 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: 4P Tmax XT1 design delivers robust protection for 4-pole power distribution networks, enabling consistent fault isolation and reducing arc fault exposure in panel boards used in manufacturing. This translates to improved equipment reliability and lower maintenance costs in process industries. Feature → TMF release with a 30 ms opening time provides rapid protection against short circuits, minimizing damage to sensitive drives and motors and reducing downtime during faults in HVAC, packaging, and conveyor systems. Feature → Front-terminal, bolt-type connections with a 6 N·m tightening torque simplify installation and field servicing, supporting faster commissioning and easier retrofit in existing switchgear and control panels. Feature → Rated current IN of 35 A and Rated Uninterrupted Current Iu of 125 A ensure stable load handling for medium-size distribution blocks, while the 500 A instantaneous setting Ii safeguards against high inrush events common in stamping, metalworking, and automation lines. Feature → High UL489 interrupting ratings (up to 65 kA at 240 V AC, 35 kA at 480 V AC, 22 kA at 600Y/347 V AC; 42 kA at 250 V DC for two poles in series; 50 kA at 500 V DC for four poles in series) provide scalable protection for diverse utility and industrial configurations. Feature → Low power loss of 2 W per pole supports energy-efficient protection schemes and reduced thermal loading in dense switchgear assemblies. Feature → Busbar compatibility with 45.5–80 mm² cross-sections enables clean integration into standard panel layouts without costly rework. Feature → Industry-leading lifecycle (electrical 8000 cycles, mechanical 25,000 cycles) delivers longer service intervals and lower replacement costs in high-use environments. Feature → End-of-life and disassembly guidance, along with EPD, RoHS, REACH and CMRT data, support sustainable disposal and regulatory reporting for corporate ESG programs.

Get a Quick Quote for a ABB 1SDA074683R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074683R1? Enquire Now

FAQs

Install in panel boards or switchgear using front-terminal connections rated for 45.5–80 mm² busbar sections. Tighten main connections to 6 N·m, verify 600Y/347 V AC rating and 35 A nominal current, and ensure the TMF release is correctly configured for the application. Use the recommended M6 screwdriver for main circuit connections and follow the disassembly instructions for end-of-life handling.
The device is a 4P MCCB with IN of 35 A, IU of 125 A, and a rated voltage of 600Y/347 V AC (and 500 V DC in applicable configurations). The instantaneous short-circuit setting Ii is 500 A, and the adjustable setting range is 35 A. Opening time is 30 ms (SOR) or 30 ms (UVR) depending on operating conditions, with a short-circuit performance level of S.
Yes, as a 4-pole Tmax XT1 device with TMF release, front terminals, and a 35 A rating, it is well-suited for motor protection and distribution in control panels. It provides fast fault clearance, robust interrupting capability, and compatibility with XT family accessories, which helps simplify motor control center designs and minimizes nuisance tripping.
The unit carries UL489/CSA recognition, CE Declaration of Conformity, RoHS and REACH declarations, CMRT for conflict minerals, TSCA compliance, and an Environmental Product Declaration (EPD). These attest to regulatory adherence, safe disposal, and sustainability considerations in global projects.
The device delivers low standby power loss (2 W per pole), leading to energy savings in steady-state operation. Its high lifecycle ratings (electrical 8000 cycles, mechanical 25,000 cycles) reduce replacement frequency, while front-terminal design facilitates quick maintenance and commissioning. Collectively, these factors translate to lower maintenance costs and improved system uptime over the equipment’s service life.