ABB 1SDA074689R1 Moulded Case Circuit Breaker safeguards electrical distribution in industrial automation. Professionals frequently struggle to balance compact panel layouts with robust protection and regulatory compliance. This XT1 TMF four-pole device carries UL489/CSA listing, CE conformity, RoHS compliance, and an environmental product declaration to support sustainable, safe installations. With front-terminals, a fixed mounting configuration, and an 80 A rating, it streamlines installation, reduces wiring complexity, and improves lifecycle cost against fluctuating demand. In practice, engineers can leverage ABB EcoSolutions tools and end-of-life guidance to optimize maintenance routines and waste reduction across panels and machinery fleets.
Product Information
Extended Description
1SDA074689R1 ABB: C.BREAKER TMAX XT1S 125 UL/CSA FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 80-800 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1SU4080AFF000XXX
EAN
8015644786663
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8015644786663
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.8 W
Rated Current (In)
80 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
900 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
80 A
Short-Circuit Performance Level
S
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA | (480 V AC) 35 kA | (600Y / 347 V AC) 22 kA | (250 V DC) 2 Poles in Series 42 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature — 4P fixed front-terminal design with busbar compatibility (45.5 to 80 mm²) enables rapid cabinet wiring. Business Impact — Reduces installation time and wiring errors, improving panel reliability and service readiness. Application — Ideal for SACE Tmax XT panel boards in manufacturing lines and process automation. Feature — TMF release with fast interruption (opening time around 30 ms) enhances fault-clearing speed. Business Impact — Limits damage from short circuits, lowers downtime, and protects connected equipment. Application — Suitable for critical drives and motors in packaging, food & beverage, and material handling. Feature — Rated current 80 A and rated voltage 600Y/347 V AC with uninterrupted current up to 125 A. Business Impact — Supports medium-power distribution without oversizing, optimizing panel footprint and energy efficiency. Application — Used in distribution sections of machinery power circuits and control panels. Feature — Robust short-circuit performance with I_i up to 900 A and UL489/CSA compliance across multiple voltages. Business Impact — Ensures regulatory compliance while delivering predictable fault protection and safe shutdown. Application — Essential for safe operation of industrial feeders and motor starter assemblies. Feature — Mechanical durability (25,000 cycles) and electrical durability (8,000 cycles per hour) with 4P operation and front-terminal connection. Business Impact — Extends asset life, reduces maintenance intervals, and improves total cost of ownership. Application — Long-term protection in heavy-use environments such as packaging lines and process plants. Feature — Environmental and sustainability data including RoHS, REACH, CMRT, EPD, and disassembly guidance. Business Impact — Supports compliant end-of-life management and waste reduction goals, aligning with corporate ESG programs. Application — Suitable for green manufacturing initiatives and regulated markets.
Get a Quick Quote for a ABB 1SDA074689R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA074689R1?
Enquire Now
FAQs
Yes. This 4P XT1 device uses fixed front terminals designed for straightforward panel mounting and secure busbar connections (70 mm depth, 101.6 mm width, 130 mm height). With a 6 N·m tightening torque and a busbar range of 45.5 to 80 mm², it fits common control cabinets and motor control centers, reducing install time and wiring errors.
The unit is rated for 80 A nominal current (I n) and 600Y/347 V AC (U r). It supports an uninterrupted current (I u) of 125 A and an instantaneous short-circuit setting (I i) of 900 A. Its 4P configuration and UL489/CSA compatibility make it suitable for harsh industrial environments requiring reliable fault interruption.
Yes. The Tmax XT1 1SDA074689R1 carries a CE Declaration of Conformity and RoHS compliance. It also includes an Environmental Product Declaration (EPD), a CMRT for conflict minerals, and disassembly instructions to support end-of-life planning and waste reduction within sustainability programs.
Ideal for power distribution in manufacturing, process automation, and machine-building environments. It is well-suited for control panels, motor starters, and transformer/protection schemes where reliable 4P protection, front-terminal accessibility, and compact footprint are advantageous, such as packaging, food & beverage processing, and automation lines.
With electrical durability rated at 8,000 cycles per hour and mechanical durability at 25,000 cycles, plan for periodic inspection rather than frequent replacement in high-use settings. The front-terminal design simplifies replacement, and the availability of disassembly instructions and end-of-life guidance helps optimize maintenance schedules and recycling workflows.