ABB 1SDA074691R1 Moulded Case Circuit Breaker - UL/CSA
Part Number: 1SDA074691R1
Quick Summary
ABB 1SDA074691R1 Moulded Case Circuit Breaker is designed for reliable low-voltage protection in industrial power distribution. In automation panels, complex wiring and unplanned downtime can derail production; this MCCB simplifies maintenance with front-terminal access and a robust TMF release for fast, predictable tripping. The device carries UL/CSA listings, CE Declaration of Conformity, and RoHS/REACH compliance, supporting global deployments and regulatory peace of mind. With a 4P XT1 design, 100 A rating, and 600Y/347 V capability, it scales across motor drives and distribution blocks, while ABB EcoSolutions resources help manage end-of-life, recycling, and sustainable project outcomes. This combination delivers reliable protection with clear, install-ready specifications for engineering teams and procurement specialists.
Product Information
Extended Description
1SDA074691R1 ABB: C.BREAKER TMAX XT1S 125 UL/CSA FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 100-1000 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1SU4100AFF000XXX
EAN
8015644786687
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8015644786687
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 7 W
Rated Current (In)
100 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
1100 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
100 A
Short-Circuit Performance Level
S
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA | (480 V AC) 35 kA | (600Y / 347 V AC) 22 kA | (250 V DC) 2 Poles in Series 42 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
The XT1 four-pole molded case design provides precise fault isolation and fast protection with a TMF release, improving machine uptime and safety in demanding production lines. This translates to measurable business impact: reduced maintenance time and lower risk of cascading outages, particularly in power-distribution panels and drive interfaces where fast disconnection is critical. The 100 A rated current and 600Y/347 V operating range support motor protection and transformer feeders across a wide voltage spectrum, enabling scalable deployment from small automation panels to multi-block distribution centers. Front-terminal connections and a 6 N·m tightening torque accelerate panel assembly and simplify field wiring, reducing commissioning time and human error. Compatibility with the SACE Tmax XT family ensures seamless integration with existing protection schemes and spare-part consistency for OEMs and end users. ABB EcoSolutions features address end-of-life and recycling considerations, helping projects meet sustainability targets and compliance requirements. In practice, engineers benefit from reliable mechanical durability (4P, 240 cycles per hour), predictable opening times (SOR 30 ms), and robust UL489/CSA protection ratings that align with global standards, easing procurement and global rollouts across sites.
Get a Quick Quote for a ABB 1SDA074691R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA074691R1?
Enquire Now
FAQs
Install the four-pole XT1 MCCB with front terminals using the recommended M6 main circuit screws and a tightening torque of 6 N·m. Plan for busbar connections within 45.5–80 mm² cross-sections, ensure correct orientation for TMF release, and leave clearance for front-access maintenance. The unit's dimensions (101.6 mm width, 130 mm height, 70 mm depth) fit standard panel cutouts, supporting quick, error‑free wiring and service.
The device is a 4P MCCB rated for 100 A with a rated voltage of 600Y/347 V AC and 500 V DC, offering an uninterrupted current (Iu) of 125 A and a instantaneous short-circuit setting (Ii) of 1100 A. It features TMF release with a 30 ms opening time, UL489/CSA compatibility, and 65 kA interrupting rating at 240 V AC under UL/CSA standards, ensuring robust protection for power distribution.
Yes. Its 4P XT1 design, 100 A rating, and 600Y/347 V capability are well-suited for motor protection and drive circuits in manufacturing. The quick-responding TMF release minimizes electrical stress on motors during fault conditions, while front-terminal wiring simplifies panel assembly and maintenance, reducing downtime during commissioning and routine servicing.
This MCCB carries UL/CSA listings, CE Declaration of Conformity, and RoHS/REACH compliance, with additional documentation such as TSCA and CMRT where applicable. End-of-life and environmental information are supported by ABB EcoSolutions, including disassembly instructions and EPD data, aiding global procurement, regulatory adherence, and sustainable project design.
Deployment can reduce downtime through reliable fault isolation and faster maintenance due to front-terminal access. Efficiency gains arise from quicker installation (6 N·m torque, M6 screws) and standardized integration within the Tmax XT ecosystem, lowering spare-part variability. Environmental certifications and recyclability data help meet corporate sustainability goals, potentially lowering total cost of ownership over the product lifecycle.