ABB 1SDA074694R1 Moulded Case Circuit Breaker - UL/CSA TMF

Part Number: 1SDA074694R1
Manufacturer
ABB
Part number
1SDA074694R1

Quick Summary

ABB 1SDA074694R1 Moulded Case Circuit Breaker protects motor and transformer circuits in industrial power systems. This compact UL489/CSA-listed device simplifies panel wiring with front terminals and a reliable thermomagnetic TMF release. For engineers facing crowded panels, it delivers quick installation, reduced downtime, and dependable overcurrent protection. Key certifications include UL489, CSA, and CE Declaration of Conformity, underscoring global compliance and safe operation in diverse markets. By aligning with ABB EcoSolutions and the SACE Tmax XT platform, the design supports predictable maintenance, streamlined spare-part planning, and lower total cost of ownership. The product also integrates with standard busbar connections and M6 main-circuit screws, supporting scalable, future-proof protection schemes in a wide range of industrial applications.

Product Information

Extended Description

1SDA074694R1 ABB: C.BREAKER TMAX XT1H 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 15-500 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1HU3015AFF000XXX
EAN
8015644786717
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644786717
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.1 W
Rated Current (In)
15 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
15 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 100 kA | (480 V AC) 65 kA | (600Y / 347 V AC) 25 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Three-pole XT1 configuration with front terminals and a TMF release provides robust overcurrent protection with straightforward installation, enabling fast panel wiring and reliable startup sequences in manufacturing lines. This improves downtime metrics and supports standardization across panel builds for consistent protection schemes. Feature → Business Impact → Application: Rated current of 15 A and rated voltage of 600Y/347 V AC allow safe use in low-to-medium power distribution and MOTOR/generator applications, reducing the risk of nuisance trips and enabling predictable performance in industrial plants. Feature → Business Impact → Application: High short‑circuit interrupting ratings per UL489 (up to 100 kA at 240 V AC, 65 kA at 480 V AC, 25 kA at 600Y/347 V AC) deliver reliable protection for transformers and feeders, minimizing damage during fault events and safeguarding downstream equipment. Feature → Business Impact → Application: 125 A rated uninterrupted current and 500 A instantaneous setting support fast, selective protection with configurable thresholds suitable for motor starters and distribution panels. Feature → Business Impact → Application: Front terminal and bolt connection with 6 N·m tightening torque plus M6 main-circuit screws enable secure, vibration-resistant installations in harsh environments, reducing maintenance need and contact resistance over time. Feature → Business Impact → Application: Compliance and environmental features including RoHS and REACH declarations, EPD, and recyclable packaging support corporate sustainability goals and regulatory readiness for global projects in energy, water treatment, and process industries. Feature → Business Impact → Application: Compact dimensions (76.2 mm width, 130 mm height, 70 mm depth) and 1.1 kg weight facilitate flexible integration into limited-space switchboards and modular panels for compact data centers and distributed control systems.

Get a Quick Quote for a ABB 1SDA074694R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074694R1? Enquire Now

FAQs

Installation is straightforward: this 3P XT1 breaker uses front connections with bolt terminals and requires a tightening torque of 6 N·m. Use the M6 main-circuit screws and ensure busbar contact area is between 45.5 and 80 mm² for optimal current carrying capacity and reliable fault isolation in panel assemblies.
Key ratings include a rated current of 15 A, rated operational voltage of 600Y/347 V AC (and 500 V DC), and a rated uninterrupted current of 125 A with a 500 A instantaneous short-circuit setting. UL489 interrupting ratings reach up to 100 kA at 240 V AC and 65 kA at 480 V AC, making it suitable for transformer and motor protection in many plant layouts.
Yes. The SACE Tmax XT XT1 family is designed for transformer and distribution protection, offering reliable overcurrent protection with TMF release. Its 3P configuration and front-terminal design simplify incorporation into compact switchgear and distribution panels used in substations and process facilities.
This unit carries UL489/CSA certification, a CE Declaration of Conformity, and associated RoHS/REACH declarations. It also provides environmental disclosures such as EPD and end-of-life information, supporting compliance across global projects and sustainability reporting.
Electrical durability is rated at up to 8000 cycles per hour and 120 cycles per hour for electrical operation, with mechanical durability up to 25,000 cycles. Plan for periodic inspection of front-terminals, verify torque at installation, and keep spare parts aligned with the Tmax XT family to minimize downtime during replacements or upgrades.