ABB 1SDA074700R1 Moulded Case Circuit Breaker - UL/CSA
Part Number: 1SDA074700R1
Quick Summary
ABB 1SDA074700R1 is a three-pole moulded case circuit breaker for UL/CSA-protected control panels. Engineers often struggle with space constraints, reliability, and meeting stringent certifications when expanding or upgrading motor control and distribution sections. Certified to UL489 and CSA CS22.2 standards, with CE Declaration of Conformity and RoHS compliance, it supports compliant installations across North America and Europe. Designed for seamless integration with the SACE Tmax XT family and ABB EcoSolutions initiatives, it delivers predictable protection, front-terminal accessibility, and reduced maintenance cost across the asset lifecycle. With a rated current of 45 A, trip characteristics TMF, and front-terminal, 3P configuration, it provides robust protection for medium-size power distribution. The solution also aligns with eco-conscious procurement through recyclable design and end-of-life guidance, helping owners meet sustainability targets.
Product Information
Extended Description
1SDA074700R1 ABB: C.BREAKER TMAX XT1H 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 45-500 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1HU3045AFF000XXX
EAN
8015644786779
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644786779
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 3 W
Rated Current (In)
45 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
45 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 100 kA | (480 V AC) 65 kA | (600Y / 347 V AC) 25 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Three-pole XT1 Tmax XT design with TMF release provides coordinated overload protection for three-phase circuits. This configuration simplifies panel zoning and minimizes nuisance trips in demanding production environments. In practice, this means fewer unplanned shutdowns and smoother start-up of motors and transformers, improving overall line availability. UL489 and CSA CS22.2 certification, complemented by CE Declaration of Conformity and RoHS compliance, support global deployments and faster regulatory approvals. Application spans motor control centers and distribution boards across North America and Europe, aligning with ABB EcoSolutions targets for waste-to-landfill reduction. Front-terminal mounting and 6 N·m tightening torque enable rapid, repeatable connections with minimal torque variance. With front-access wiring, installers can work from the panel face, reducing field errors and wire fatigue during maintenance. Environmental data, including EPD for Tmax XT1 and a recyclability rate of 55.9% per EN45555, support sustainable procurement and end-of-life planning, reducing total cost of ownership. Electrical performance features include rated current of 45 A, rated voltage of 600Y/347 V AC and 500 V DC, along with a short-circuit setting of 500 A, making it suitable for medium-power distribution, transformer protection, and MCCs. Compatibility details such as a busbar range of 45.5 to 80 mm² and a recommended screwdriver of M6 streamline field installation and future upgrades.
Get a Quick Quote for a ABB 1SDA074700R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA074700R1?
Enquire Now
FAQs
The ABB 1SDA074700R1 is certified to UL489 and CSA CS22.2 standards, includes a CE Declaration of Conformity, and is RoHS compliant, facilitating regulatory approvals and smooth deployments in North American and European equipment builds.
Front-terminal mounting provides easier access for wiring, faster torque verification (6 N·m), and safer, neater terminations. It reduces panel depth and enables quicker maintenance without sacrificing connection reliability.
Yes. The unit supports 600Y/347 V AC and 500 V DC, making it appropriate for medium-power distribution in MCCs and other three-phase power applications, with rated current of 45 A and TMF release for reliable protection.
Electrical durability is rated at 120 cycles per hour with up to 8000 total cycles, while mechanical durability is 240 cycles per hour and up to 25,000 cycles, indicating strong long-term performance under typical industrial duty cycles.
ABB provides an Environmental Product Declaration (EPD) for Tmax XT1, recyclability rated at 55.9% per EN45555, along with end-of-life disassembly instructions and RoHS/CMRT data to support sustainable procurement and responsible disposal.