ABB Tmax XT 1SDA074702R1 Moulded Case Breaker - UL/CSA

Part Number: 1SDA074702R1
Manufacturer
ABB
Part number
1SDA074702R1

Quick Summary

ABB Tmax XT 1SDA074702R1 Moulded Case Breaker is a fixed three-pole protection device for industrial power distribution. Engineers often struggle with wiring complexity, limited panel space, and ensuring UL/CSA compliance across sites. This XT1 family piece carries UL489, CSA, and CE declarations, plus RoHS and REACH compliance, with lifecycle data like EPD and recyclability. Designed for panel builders and system integrators, it delivers reliable protection while simplifying installation and service, reducing downtime and total cost of ownership in demanding environments.

Product Information

Extended Description

1SDA074702R1 ABB: C.BREAKER TMAX XT1H 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 60-600 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
bab4f88a-5f5f-4cd4-9357-e98d7fa445af Italy (IT)
Simplified SCIP
ef3966bb-45a4-4435-974d-b64ac5ed7935 Germany (DE) | ce8bc15f-438d-48b7-ad26-795dff3aaf36 Sweden (SE) | ef579ec2-7a29-45c3-929d-1cbbc25f84f1 Denmark (DK) | ce2c1fce-b90d-49de-bd89-ad0fa429e3d5 Germany (DE) | e845b212-5a27-4781-b88c-aac72eda39a8 France (FR) | 086293e9-5bb4-4a7b-b56c-77163a31e6b5 Croatia (HR) | 5390cde0-5316-474b-9855-f8299d0205e2 Germany (DE) | 3579434e-0179-4fae-9151-007c68a85600 Czech Republic (CZ) | 9ee41204-e523-413c-860c-d78be7278a3c Belgium (BE) | 178092f5-58d1-4288-9065-b67099a7d1c1 Spain (ES) | 8e6dad07-8531-4dd9-bd4b-b8263f451592 Hungary (HU) | b105182b-2455-48ed-9115-985f1428b470 Belgium (BE) | 0576b1ec-bb90-4683-91ff-ea0c3e6f9703 Estonia (EE) | f78fe3f2-8a72-445f-8be6-700fa6a7b3f1 Finland (FI) | e63d3eda-e09d-49ea-a378-ef8817b946a0 Netherlands (NL) | 3e715fc8-5208-4a8f-ae8a-fe4f1fe749c6 Poland (PL) | 311af6a3-23fe-4898-a312-efc3b2661681 Hungary (HU) | ce28fa81-6e50-4f07-b7f7-ae967ed2f110 Greece (GR) | 24efc020-0f2c-42f2-87d8-c8e5c741e4f9 France (FR) | aae7d9fa-64f8-462b-853a-90c4311605e0 Bulgaria (BG) | 2dcb922d-7b40-4359-98b3-49ec14a361bb Poland (PL) | 1ae2b5d4-08cf-4f14-9ae1-704351f2c8e0 Poland (PL) | 853a9fac-7b5a-4f61-a8bc-c0ac3907b006 Norway (NO) | 84e4f177-89f9-424e-9ae3-4dfbdb748c1e Sweden (SE) | 11b3d7d2-f266-4840-b893-3c23b39ff4dd Germany (DE) | 575d218d-6e5e-450d-a201-4fe6f6dc3ac2 Germany (DE) | 86c2381b-0e86-4db4-88f5-fa84331c3695 Portugal (PT)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1HU3060AFF000XXX
EAN
8015644786793
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644786793
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 3.9 W
Rated Current (In)
60 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
600 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
60 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 100 kA | (480 V AC) 65 kA | (600Y / 347 V AC) 25 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Fixed three-pole TMF release protects against overloads and short-circuits with predictable tripping. Business Impact: Improves system reliability and safety while reducing nuisance trips in motor and transformer protection. Application: Suitable for control panels, distribution boards, and MCCs in industrial facilities. Feature: Front-terminal connections enable fast, secure wiring and simplified field maintenance. Business Impact: Cuts install time and minimizes wiring errors, boosting panel assembly throughput. Application: Used during initial install or panel retrofit projects. Feature: XT1 sub-type with 60 A setting range and 125 A Iu rating supports scalable protection for mid-range loads. Business Impact: Flexible sizing avoids over- or under-protection, lowering spare-part inventories. Application: Transformer feed protection and generic distribution circuits. Feature: Comprehensive environmental and compliance data including RoHS, REACH, EP D, and simplified SCIP. Business Impact: Eases regulatory reporting and end-of-life planning, improving sustainability metrics. Application: Corporate ESG programs and supplier approvals. Feature: Durable electrical and mechanical life: 8000 electrical cycles, 25000 mechanical cycles, and 30 ms opening time. Business Impact: Enhances uptime in high-velocity switching applications and reduces maintenance costs. Application: High-demand panels in manufacturing and processing plants. Feature: Compact dimensions and modest weight (76.2 mm W, 130 mm H, 70 mm D; 1.1 kg). Business Impact: Facilitates footprint-conscious panel design and shipping efficiency. Application: Space-constrained switchgear and retrofit projects.

Get a Quick Quote for a ABB 1SDA074702R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074702R1? Enquire Now

FAQs

The XT1 1SDA074702R1 uses front-terminal connections, ideal for panel-mounted distribution boards and MCCs. This enables secure wiring in tight spaces, simplifies field servicing, and aligns with standard MCB mounting patterns used across ABB SACE Tmax XT family installations.
Rated current is 60 A with a rated operational voltage of 600Y/347 V AC and 500 V DC. Short-circuit capability varies by voltage level (UL489) up to 100 kA at 240 V, 65 kA at 480 V, and 25 kA at 600Y/347 V AC. Release is TMF with a 30 ms opening time and tightening torque of 6 N·m.
Ideal for power distribution in industrial facilities, transformer protection, and motor control centers. Its TMF trip, 3P configuration, and front-terminal wiring streamline installation in control panels and switchgear while delivering dependable protection for medium-duty loads.
Look for UL489 and CSA certifications, plus the CE Declaration of Conformity. The unit carries a UL certificate (1SDL000163R0111) and a CSA certificate (Intrinsic Safe), with RoHS and REACH declarations to support regulatory compliance.
Electrical durability is rated at 8000 cycles and mechanical durability at 25,000 cycles, with a 30 ms opening time for fast fault clearance. End-of-life guidance and disassembly instructions support recycling and sustainable disposal, contributing to reduced maintenance costs and better TCO.