ABB 1SDA074706R1 Moulded Case Circuit Breaker - UL/CSA
Part Number: 1SDA074706R1
Quick Summary
1SDA074706R1 is a three-pole molded case circuit breaker for industrial power distribution. Engineers rely on dependable protection across 600Y/347 V systems, and this device reduces nuisance trips while simplifying maintenance. Key certifications include UL489 and CSA compliance, with a CE declaration of conformity and VDE notes reinforcing safety and regulatory alignment. Built into ABB’s Tmax XT family, it offers front-terminal accessibility, a TMF thermal-magnetic release, and a 100 A rating for scalable protection. From installation to end-of-life, this solution supports sustainable practices with recyclability targets and ABB EcoSolutions data to help meet corporate sustainability goals.
Product Information
Extended Description
1SDA074706R1 ABB: C.BREAKER TMAX XT1H 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 100-1000 A
Country of Origin
Italy (IT)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
5b7a7380-c053-433a-9f61-08fa87722d7b Italy (IT)
Simplified SCIP
e0586616-1069-4194-b884-80e044d27193 Germany (DE) | 37c6df43-5e1b-4817-b794-339ac18e23a6 Croatia (HR) | 37f6e4cc-48cd-4fea-a24f-03cac81d35c3 Czech Republic (CZ) | fc0cee72-60eb-4d8e-8a8d-eaebe44aab19 Denmark (DK) | 17367a5e-3f4d-49e3-b5e5-9c543ad6bf94 Sweden (SE) | eb2f426b-7b73-4cea-881a-d7dd0ad79c2d Germany (DE) | c23ff3ce-9400-4e4e-927b-ad22450fb521 France (FR) | ebeae46e-76b7-4513-92e4-f800040c451e Germany (DE) | 9261ffca-86bc-405b-91f4-319fd846ddc6 Hungary (HU) | 1fa6f5fc-7ba3-4dda-a01d-f6adab7893b2 Spain (ES) | 075b1678-7e71-48cd-9824-fc260f2f152e Belgium (BE) | 3bd5d061-e310-4064-b60c-6b3bd7f94885 France (FR) | b980ed83-55d9-4544-990c-daa669a4b982 Poland (PL) | 2562a00b-094b-4ff0-8520-de14820294fd Germany (DE) | 78898227-54dd-4a64-bcd4-e3fc834099f2 Germany (DE) | 064d5381-d941-4413-aca7-e7b73cd64aeb Portugal (PT) | 949f3ba9-8f37-4702-a1f6-180ea8467b98 Poland (PL) | 2e4d5011-a2c7-4793-9bea-a292444c8bb4 Netherlands (NL) | f6087d44-cd7a-47ec-94a7-5737a8cb8e60 Sweden (SE) | 0f434782-16d3-4e4a-b24b-e9cb81c9f4da Norway (NO) | 6fe277ca-3bf6-4ed1-90d7-8bbfd05cf69a Bulgaria (BG) | b7c3cec4-ee79-4e84-8c3e-26c94501e45e Poland (PL) | d2503023-b537-4a63-84f4-50a3fed6dbdb Finland (FI) | 42d1e26f-e329-4a45-8fd9-3cc95ce7a224 Hungary (HU) | c8c834db-a5d2-4cbe-89a1-9b6710822da8 Greece (GR) | 256ff5cf-d3b5-4e0b-9f9f-88f7afc88917 Estonia (EE) | 26b02900-a58a-45ed-a2ee-0b51d4aac893 Belgium (BE)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1HU3100AFF000XXX
EAN
8015644786830
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644786830
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 7 W
Rated Current (In)
100 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
1000 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
100 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 100 kA | (480 V AC) 65 kA | (600Y / 347 V AC) 25 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Rated current of 100 A delivers reliable protection for standard distribution blocks, reducing unplanned outages and extending equipment life across manufacturing cells. In practice, this translates to lower maintenance costs and improved line availability in automation lines and conveyor systems. Feature → Application: Front terminal connections and bolt-type terminals enable quick, secure installation with minimal torque requirements of 6 N·m, accelerating commissioning while maintaining robust electrical performance. Feature → Business Impact → Application: TMF thermal-magnetic release provides precise overcurrent protection, minimizing nuisance tripping in high-load applications such as transformers and motor feeders, and enabling smoother startup sequences in metalworking and packaging lines. Feature → Application: Rated voltage of 600Y/347 V AC and 500 V DC supports mixed-voltage architectures typical in process plants, enabling a single protective device across multiple zones. Feature → Business Impact → Application: 3P configuration and compact XT dimensions simplify panel layout, reducing cabinet space and enabling scalable upgrades for expanding lines. Feature → Application: ABB EcoSolutions data, RoHS/REACH compliance, and EN45555 recycling guidance help procurement meet sustainability and regulatory requirements while preserving total cost of ownership.
Get a Quick Quote for a ABB 1SDA074706R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA074706R1?
Enquire Now
FAQs
For proper installation, ensure front-terminal connections using bolt terminals with a tightening torque of 6 N·m. Use busbars sized 45.5 to 80 mm² and confirm the unit is mounted in a 3P configuration within a compatible ABB switchgear or panel. Verify compliance with UL489 and CSA standards and secure the device firmly to prevent vibration-induced wear.
The breaker is rated for 100 A (In) with a rated operational voltage of 600Y/347 V AC and 500 V DC. It supports an interrupting rating per UL489 up to 100 kA at 240 V, 65 kA at 480 V, and 25 kA at 600Y/347 V, with a rated instantaneous setting Ii of 1000 A and an uninterrupted current (Iu) of 125 A.
Yes. The device carries UL489 and CSA certificates (Intrinsic Safe CSAs), a CE Declaration of Conformity for Tmax XT1, and a UL certificate number 1SDL000163R0111, ensuring compliance for low-voltage applications in the US, Canada, and European markets.
Ideal for main distribution and transformer protection in switchgear and control panels, it supports 3P protection for compact power distribution blocks, motor feeders, and process line cabinets. Its front-terminal design simplifies retrofit and upgrades in existing layouts, while its compatibility with 600Y/347 V systems makes it suitable for mixed- voltage plant architectures.
The XT1 breaker aligns with ABB EcoSolutions, offering an Environmental Product Declaration (EPD) for Tmax XT XT1, recyclability rated at 55.9% per EN45555, and end-of-life disassembly instructions. It also provides CMRT data and RoHS/REACH declarations, supporting responsible sourcing, waste reduction, and regulatory reporting.