ABB 1SDA074713R1 Moulded Case Circuit Breaker - UL/CSA
Part Number: 1SDA074713R1
Quick Summary
Moulded Case Circuit Breaker ABB 1SDA074713R1 protects power distribution panels and equipment by interrupting faults in industrial applications. Users struggle with coordinating protection settings and maintaining front-terminal accessibility in compact switchgear. This device holds UL489 and CSA certification for UL/CSA protection, CE declaration of conformity, and RoHS compliance for sustainable use. Designed to integrate with SACE Tmax XT product families and front-terminal assemblies, it delivers fast, reliable trips that reduce downtime and improve compliance. Its compact XT1 form factor and front-terminal design simplify installation and service in crowded panels. With TMF electromagnetic release and 35 A rated current, it matches standard busbar connections and reduces spare parts.
Product Information
Extended Description
1SDA074713R1 ABB: C.BREAKER TMAX XT1H 125 UL/CSA FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 35-500 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1HU4035AFF000XXX
EAN
8015644786908
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8015644786908
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2 W
Rated Current (In)
35 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
35 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 100 kA | (480 V AC) 65 kA | (600Y / 347 V AC) 25 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Four-pole fixed XT1 with front terminals enables straightforward wiring and secure panel mounting, while the TMF release delivers fast, predictable trips. This reduces installation time and improves protection coordination across feeders, minimizing commissioning delays. Suitable for power distribution and transformer protection in industrial facilities where space is tight and wiring quality matters. Rated to 35 A and 600Y/347 V AC (500 V DC), with a setting range of 35 A and an instantaneous fault current of 500 A, this MCCB provides precise overcurrent protection under mixed AC/DC conditions. The four poles and bolt-terminal design deliver robust, vibration-resistant connections. Installation wins include a recommended tightening torque of 6 N·m and clear front-access wiring for reliable service. Compliance across UL489, CSA, CE, RoHS, CMRT, and TSCA ensures global acceptance and regulatory readiness. This broad certifications set reduces hold-ups in audits and export processes, and supports sustainability reporting via EPD and EN45555 recyclability. Electrical durability is rated for up to 8000 operating cycles, and mechanical durability up to 25,000 cycles, supporting frequent switching in motors and transformers. This reduces maintenance costs and extends service intervals, particularly in high-switching environments. ABB EcoSolutions indicates eco-friendly lifecycle options such as 55.9% recyclability per EN 45555, end-of-life disassembly instructions, and packaging disposal guidance. This supports green procurement goals and aligns with sustainability reporting requirements. Compact footprint measures 101.6 mm wide, 130 mm high, 70 mm deep, weighs 1.4 kg, and uses front-terminal bolt connections suitable for busbars 45.5 to 80 mm². Designed for SACE Tmax XT families and standard panel layouts, it simplifies spare parts planning and stocking.
Get a Quick Quote for a ABB 1SDA074713R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA074713R1?
Enquire Now
FAQs
ABB 1SDA074713R1 uses four front‑terminal bolt connections designed for busbars in the 45.5 to 80 mm² range. It requires a tightening torque of 6 N·m to ensure a secure connection. The unit measures 101.6 mm in width, 130 mm in height, and 70 mm in depth, weighing 1.4 kg. It is intended for panel mounting in industrial power distribution and transformer protection schemes, with front-access wiring that speeds maintenance.
This device is rated for 35 A (In) with a rated voltage of 600Y/347 V AC and 500 V DC. It has a setting range of 35 A and an instantaneous short-circuit current setting (Ii) of 500 A. The unit is a 4P breaker with TMF release, suitable for both AC and DC fault conditions, and designed to mount on standard busbar connections for reliable protection of feeders.
The MCCB complies with UL489 and CSA for UL/CSA protection, with a CE declaration of conformity for European installations. It is RoHS compliant, and ABB provides CMRT, TSCA declarations, and an Environmental Product Declaration (EPD) for Tmax XT. These certifications streamline cross‑regional approvals and support regulatory reporting and sustainability programs.
Best suited for power distribution panels, transformer protection, and switchgear where front-terminal accessibility and reliable four-pole protection are needed. It pairs with SACE Tmax XT families for standardized protection across sites. The front-terminal, bolt-type connections simplify installation in tight spaces and support rapid maintenance in motor control centers and distribution boards.
The device aligns with environmental and lifecycle goals via EPD for Tmax XT, RoHS and REACH declarations, and CMRT for conflict minerals reporting. End‑of‑life disassembly instructions and packaging disposal guidance help meet corporate sustainability targets, while the 55.9% recyclability target under EN45555 informs responsible product stewardship and circular economy initiatives.