ABB 1SDA074717R1 Moulded Case Circuit Breaker - UL/CSA

Part Number: 1SDA074717R1
Manufacturer
ABB
Part number
1SDA074717R1

Quick Summary

ABB 1SDA074717R1 Moulded Case Circuit Breaker XT1H protects electrical distribution in panels and transformers. It delivers reliable overload and short-circuit protection for four-pole installations with front terminals and TMF release. For engineers, the challenge is delivering safe, compliant protection while minimizing wiring complexity and downtime; this device provides a robust 60 A rated current and a 600Y/347 V rating, with clear instantaneous settings at 600 A and accessible front-terminal mounting. Certifications include UL489 and CSA with a CE declaration of conformity, ensuring regulatory alignment across North American and European projects. By combining EcoSolutions considerations, RoHS compliance, and a design that supports easy installation and disassembly, it reduces lifecycle costs and streamlines maintenance in industrial power networks.

Product Information

Extended Description

1SDA074717R1 ABB: C.BREAKER TMAX XT1H 125 UL/CSA FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 60-600 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1HU4060AFF000XXX
EAN
8015644786946
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8015644786946
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 3.9 W
Rated Current (In)
60 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
600 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
60 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 100 kA | (480 V AC) 65 kA | (600Y / 347 V AC) 25 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 4 Poles in Series Kind 50 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3905
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
UL Certificate
1SDL000163R0111
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The XT1H four-pole design with front terminals (Bolt connections) simplifies wiring and speeds panel assembly, reducing installation time and field error. This translates to lower labor costs and improved reliability in distribution boards across manufacturing lines and transformer housings. Feature → Business Impact → Application: TMF (thermomagnetic) release provides precise trip protection for overloads and short circuits, enhancing safety and minimizing unplanned downtime in critical processes such as metalworking or chemical plants. Feature → Business Impact → Application: Rated current of 60 A and rated operational voltage of 600Y/347 V (with 500 V DC capability) enables protection for medium-load feeders and mixed AC/DC circuits, supporting compact, scalable architectures in new builds and upgrades. Feature → Business Impact → Application: Front-terminal, bolt-type connections support quick maintenance and safe disconnection, ideal for modular cabinets and retrofits where accessibility is key. Feature → Business Impact → Application: RoHS, REACH, and EPD compliance underpin sustainability programs and corporate ESG reporting, while 55.9% recyclability supports design-for-closing resource loops per EN45555, aligning with waste-reduction targets. Feature → Business Impact → Application: UL489 and CSA listings, along with DoC and packaging/disassembly instructions, streamline procurement, compliance audits, and end-of-life planning for global projects in data centers, factories, and power distribution rooms. Feature → Business Impact → Application: Documentation and CAD drawings (XT1 4P fixed front terminals) facilitate accurate installation planning, reducing guesswork and ensuring compatibility with existing busbars (45.5–80 mm²) and 6 N·m tightening torque requirements.

Get a Quick Quote for a ABB 1SDA074717R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074717R1? Enquire Now

FAQs

The XT1H 4P model uses front, bolt-type terminals designed for busbars sized 45.5 to 80 mm² and requires a tightening torque of 6 N·m. This simplifies retrofit projects and ensures secure, compliant connections in panel boards and distribution cabinets.
Interruption ratings at UL489/CSA levels vary by voltage: up to 100 kA at 240 V AC and 65 kA at 480 V AC, with 25 kA at 600Y/347 V AC for two-pole in series and 50 kA at 250 V DC, or 4 poles in series up to 50 kA at 500 V DC. These figures support coordinated protection for feeders and transformers.
Yes. With 4P configuration, 60 A I_n, and 600Y/347 VAC (plus 500 V DC) ratings, the XT1H is well-suited to protect transformer feeds and critical power distribution in data centers and industrial facilities, delivering reliable tripping behavior and easy integration with existing switchgear.
The unit carries UL489 and CSA certifications, CE Declaration of Conformity for Tmax XT, and a CSA certificate 9AKK10103A3905. End-of-life and environmental disclosures include RoHS, REACH, and an EPD, supporting regulatory and sustainability programs.
With TMF protection, 8,000 mechanical cycles, and a 60 A rating, maintenance intervals are predictable and downtime-minimizing. End-of-life packaging and disassembly guidance streamline recycling, supporting lower total cost of ownership and better ESG reporting for facilities and OEMs.