ABB 1SDA074793R1 Moulded Case Circuit Breaker - UL/CSA

Part Number: 1SDA074793R1
Manufacturer
ABB
Part number
1SDA074793R1

Quick Summary

ABB 1SDA074793R1 Moulded Case Circuit Breaker protects electrical feeders in industrial power networks against overloads. For maintenance teams, unexpected trips and misconfiguration can disrupt production and extend downtime. This XT2 series device carries UL489 and CSA certifications, CE conformity, and a DoC, ensuring reliable cross‑border compliance. Its front-terminal design, TMF release, and fixed three-pole configuration streamline installation and service while delivering robust protection. By standardizing on this MCCB, your facility gains predictable protection, lower spare‑parts complexity, and alignment with ABB Tmax XT performance standards for energy efficiency and sustainable operation.

Product Information

Extended Description

1SDA074793R1 ABB: C.BREAKER TMAX XT2H 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 35-400 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HU3035AFF000XXX
EAN
8015644787707
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.2 kg
Package Level 1 EAN
8015644787707
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.8 W
Rated Current (In)
35 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
400 A
Rated Operational Voltage
600 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
35 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 150 kA | (480 V AC) 65 kA | (600 V AC) 25 kA | (250 V DC) 2 Poles in Series 65 kA | (500 V DC) 3 Poles in Series 65 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3906
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
UL Certificate
1SDL000163R0112
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT2 UL | Release assembly XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Three‑pole TMF release with front terminals enables fast, safe fault isolation and straightforward panel mounting, reducing arc flash exposure and service time for maintenance personnel. This directly translates to improved uptime and lower labor costs in critical production environments. The device supports a 35 A rated current with a 600 V operating voltage, delivering reliable protection for distribution boards and transformer feed lines while maintaining compact, manufacturer‑recommended wiring practices for busbar connections (32.5–100 mm²). The fixed XT2 design, M6 main circuit screws, and a 6 N·m tightening torque ensure dependable, vibration‑resistant connections in harsh industrial settings, minimizing retightening cycles and contact resistance over time. Compliance with UL489, CSA CS22.2, and CE standards reduces regulatory risk and simplifies audits, while RoHS/REACH declarations support sustainability goals and waste management targets. Installation compatibility with SACE Tmax XT family enhances spare‑parts compatibility across sites, reducing inventory complexity and downtime during replacements. In practice, engineers gain faster commissioning, safer maintenance windows, and a clear path to lifecycle cost reduction without compromising protection performance.

Get a Quick Quote for a ABB 1SDA074793R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074793R1? Enquire Now

FAQs

The 1SDA074793R1 is designed for fixed front terminal mounting with 3P XT configurations. It accepts busbar sizes from 32.5 to 100 mm² and uses standard M6 main circuit screws, simplifying panel integration and reducing rework during retrofit projects. Ensure correct tightening to 6 N·m and verify alignment with existing Tmax XT family components for seamless compatibility.
Key specs include rated current In of 35 A, rated voltage Ur of 600 V, rated uninterrupted current Iu of 125 A, rated instantaneous short‑circuit current setting Ii of 400 A, and a 3P configuration with TMF release. The device complies with UL489 and CSA CS22.2, enabling compliant protection in both North American and European installations when used within its operating range.
Yes, the XT2 family is designed for transformer and distribution protection in low‑voltage networks. The 3P arrangement with TMF release supports reliable short‑circuit interruption, while the front-terminal design simplifies wiring to transformer feeders. For legacy transformer protection schemes, confirm busbar sizing, voltage rating, and coordination with upstream protective devices to ensure selective tripping.
The product carries UL489/CSA CS22.2 certifications, CE conformity, and a DoC, plus a UL certificate (1SDL000163R0112) and a CSA intrinsic safety certificate (9AKK10103A3906). These attest to electrical safety, cross‑border compliance, and environmental/regulatory standards, reducing procurement risk and simplifying audits for multinational facilities.
The MCCB’s durable front‑terminal design and TMF release reduce service time and maintenance costs by enabling quicker fault isolation. Its compatibility with the Tmax XT ecosystem lowers spare‑part inventory and improves lifecycle planning. Expect lower downtime, faster commissioning, and predictable protection performance, contributing to a favorable total cost of ownership over the equipment’s lifespan.