ABB 1SDA074802R1 is a moulded case circuit breaker designed for reliable protection in low-voltage switchgear and panel boards. Engineers often struggle to balance fast fault isolation with uptime and lifecycle costs in demanding environments. This XT2 device carries UL489 and CSA listings with CE conformity, plus RoHS and REACH declarations, supporting global compliance. As part of the SACE Tmax XT family, it delivers scalable protection in compact footprints, with front-terminal wiring and a 3P configuration that simplifies installation and service. The result is safer, more predictable protection for critical processes while reducing total cost of ownership and maintenance overhead.

Product Information

Extended Description

1SDA074802R1 ABB: C.BREAKER TMAX XT2H 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 125 I3=625...1250 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HU3125BFF000XXX
EAN
8015644787790
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.2 kg
Package Level 1 EAN
8015644787790
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Accessory
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 11.4 W
Rated Current (In)
125 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
625…1250 A
Rated Operational Voltage
600 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
87.5...125 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Fixed Circuit-Breakers
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 150 kA | (480 V AC) 65 kA | (600 V AC) 25 kA | (250 V DC) 2 Poles in Series 65 kA | (500 V DC) 3 Poles in Series 65 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3906
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
UL Certificate
EC Declaration of Conformity Tmax XT2
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT2 UL | Release assembly XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Fixed three-pole front-terminal design with bolt connections. Business Impact: Provides secure, low-error wiring and faster field terminations, reducing installation time and miswiring risks. Application: Ideal for compact SACE Tmax XT panels in industrial plants. Feature: Adjustable instantaneous short-circuit current setting from 625 to 1250 A and a 87.5–125 A setting range. Business Impact: Enables precise coordination and selectivity, minimizing nuisance trips while protecting transformers and feeders. Application: Protection in motor and transformer feeders within low-voltage switchgear. Feature: Rated current 125 A and rated operational voltage of 600 V AC / 500 V DC. Business Impact: Delivers predictable protection envelopes and compatibility with common distribution architectures, reducing design time. Application: Main circuit protection in distribution boards and power cabinets. Feature: High durability—electrical durability up to 8000 cycles and mechanical durability up to 25000 cycles. Business Impact: Extends service life in high-switching environments, lowering maintenance frequency and cost. Application: Frequent switching scenarios in process plants and data centers. Feature: Compliance and sustainability suite—UL489, CSA, CE, RoHS, REACH, and EPD with recyclability data. Business Impact: Eases regulatory approvals, supports green procurement, and aligns with corporate sustainability targets. Application: OEMs and integrators seeking auditable compliance for global projects. Feature: Front-terminal, busbar-compatible connection for 32.5–100 mm² and tightening torque of 6 N·m. Business Impact: Streamlines installation, reduces risk of loose connections, and supports robust long-term performance. Application: Panel assembly in high-demand industrial environments.

Get a Quick Quote for a ABB 1SDA074802R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074802R1? Enquire Now

FAQs

The device uses fixed three-pole front terminals with bolt connections and accepts busbars from 32.5 to 100 mm². Tightening torque is 6 N·m, simplifying secure installation and reducing field errors. It is designed for XT2 front-terminal configurations and fits standard SACE Tmax XT assemblies.
Rated current is 125 A with a setting range of 87.5 to 125 A. The instantaneous setting ranges from 625 to 1250 A. Rated operational voltage is 600 V (AC) / 500 V (DC). It features 3 poles and a TM release type (TMA), suitable for selective protection in low-voltage feeders.
Yes. It carries UL489 compatibility, CSA certification (9AKK10103A3906), and a CE Declaration of Conformity for Tmax XT2. Additional RoHS and REACH declarations support substance compliance, while EPD and recyclability information assist in sustainable procurement and end-of-life planning.
It is ideal for SACE Tmax XT protection in low-voltage switchgear, transformers, and panel boards. The 3P configuration, front-terminal design, and adjustable I_i setting support motor, transformer, and distribution feeders requiring reliable short-circuit protection and easy integration into existing XT2 systems.
Electrical durability up to 8000 cycles per hour and mechanical durability up to 25000 cycles reduce maintenance frequency in high-switching environments. Available disassembly instructions and packaging disposal guidance help with routine maintenance, recycling, and compliant end-of-life handling, contributing to lower total cost of ownership over the device lifecycle.