ABB 1SDA074804R1 Moulded Case Circuit Breaker - UL/CSA

Part Number: 1SDA074804R1
Manufacturer
ABB
Part number
1SDA074804R1

Quick Summary

ABB 1SDA074804R1 Moulded Case Circuit Breaker protects electrical distribution in industrial panels. It is designed to reliably interrupt faults and guard critical power circuits where safety and uptime matter. Engineers often struggle to find a device that combines UL489/CSA protection with reliable front‑terminal installation in compact enclosures. This unit carries UL489 and CSA approvals and a CE declaration, ensuring compliant operation across North American and European panels. Built for SACE Tmax XT ecosystems, it delivers robust short‑circuit protection, predictable maintenance cycles, and easy field replacement. The combination of a 4‑pole fixed front-terminal design and TMF release supports streamlined wiring, faster commissioning, and lower lifecycle costs for high‑demand facilities.

Product Information

Extended Description

1SDA074804R1 ABB: C.BREAKER TMAX XT2H 125 UL/CSA FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 20-400 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HU4020AFF000XXX
EAN
8015644787813
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.55 kg
Package Level 1 EAN
8015644787813
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT2 4p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.6 W
Rated Current (In)
20 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
400 A
Rated Operational Voltage
600 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
20 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 150 kA | (480 V AC) 65 kA | (600 V AC) 25 kA | (250 V DC) 2 Poles in Series 65 kA | (500 V DC) 3 Poles in Series 65 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3906
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
UL Certificate
1SDL000163R0112
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT2 UL | Release assembly XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Four‑pole, front‑terminal construction provides clean, accessible wiring and reduces installation time, while a 20 A rated current and 600 V rating deliver reliable protection for moderate power distribution in industrial facilities. This translates to less nuisance trips and lower risk of arc faults in panels, especially where motor loads or transformers are present. Application: ideal for SACE Tmax XT installations in control cabinets and switchgear where compact footprint and front‑access terminals save space and simplify commissioning. Feature → Business Impact → Application: TMF (thermal magnetic) release delivers fast, reliable tripping with a typical opening time around 30 ms, minimizing fault energy and protecting downstream equipment. Application: suitable for critical feeders and transformer protections in distribution systems. Feature → Business Impact → Application: 4P configuration and front terminal connection support easy busbar integration and modular partitioning, enabling scalable panel design and reduced wiring complexity. Application: panel builders seeking repeatable, code‑compliant protection blocks. Feature → Business Impact → Application: Compliance with UL489, CSA, and CE declarations reduces engineering overhead and accelerates approvals for multinational deployments. Application: multinational plants requiring harmonized protection standards. Feature → Business Impact → Application: EcoSolutions and recyclability data promote sustainable design choices, aiding in cradle‑to‑grave planning and end‑of‑life handling. Application: long‑term sustainability programs in manufacturing environments. Feature → Business Impact → Application: 4P, front‑terminal, 32.5–100 mm² busbar compatibility and M6 screw‑driver guidance streamline installation and maintenance. Application: technicians performing field replacements or upgrades in existing switchboards.

Get a Quick Quote for a ABB 1SDA074804R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074804R1? Enquire Now

FAQs

The ABB 1SDA074804R1 is designed for SACE Tmax XT low‑voltage applications and fits standard distribution panels that require four‑pole front‑terminal circuit breakers. It supports UL489/CSA requirements and CE declarations, making it suitable for multinational installations. When planning a retrofit, verify busbar size (32.5–100 mm²) and front‑terminal accessibility to ensure a clean field integration with existing switchgear.
This MCCB is rated at 20 A with a rated operational voltage of 600 V and a rated uninterrupted current of 125 A. It provides an instantaneous short‑circuit setting of 400 A and a breaking capacity specified under UL489/CSA. The device uses a front‑mounted 4P configuration, with a recommended screwdriver size of M6 for main circuit connections and a tightening torque of 6 N·m.
Yes. The unit is listed under UL489 and CSA standards, with accompanying CSA and UL certificates referenced in the datasheet. It also carries a CE declaration of conformity, enabling use in European electrical installations. This combination supports cross‑border procurement and simplifies compliance workflows for manufacturers operating in multiple regions.
Designed for durability and repeatability, the 1SDA074804R1 offers 8,000 electrical cycles and up to 25,000 mechanical cycles, reducing replacement frequency and unplanned downtime. Front‑terminal access simplifies wiring checks and field servicing, while TMF protection ensures fast, predictable trips, helping maintenance teams isolate faults quickly and restore service with minimal disruption.
Plan for a front‑access installation with busbars in the 32.5–100 mm² range and ensure adequate panel space for the 120 mm × 130 mm footprint and 1.45 kg weight. Use the recommended M6 screwdriver and torque of 6 N·m for secure terminal connections. Verify clearance for front terminals and maintain proper wiring routing to prevent interference with neighboring devices.