ABB 1SDA074807R1 Moulded Case Circuit Breaker - UL/CSA
Part Number: 1SDA074807R1
Quick Summary
ABB 1SDA074807R1 Moulded Case Circuit Breaker protects industrial power systems in panels and switchgear. Engineers upgrading legacy protection face space constraints, complex wiring, and compliance gaps that slow projects. UL489 and CSA certifications ensure safe, regulatory protection, while CE conformity and RoHS/REACH declarations support global deployments. Designed for efficient field and panel installation, this device combines front-terminal connectivity, TMF release, and reliable current ratings to minimize downtime and extend asset life. With a compact footprint and clear documentation, procurement teams can streamline sourcing and standardize protection across multiple lines. This makes it a practical choice for electrical distribution tasks in manufacturing, data centers, and process industries where uptime matters.
Product Information
Extended Description
1SDA074807R1 ABB: C.BREAKER TMAX XT2H 125 UL/CSA FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 35-400 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HU4035AFF000XXX
EAN
8015644787844
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.55 kg
Package Level 1 EAN
8015644787844
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT2 4p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.8 W
Rated Current (In)
35 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
400 A
Rated Operational Voltage
600 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
35 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 150 kA | (480 V AC) 65 kA | (600 V AC) 25 kA | (250 V DC) 2 Poles in Series 65 kA | (500 V DC) 3 Poles in Series 65 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3906
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
UL Certificate
1SDL000163R0112
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT2 UL | Release assembly XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
4-p fixed front-terminal design provides easy wiring access, reducing installation time and improving panel density. Feature → Business Impact → Application: Front terminals simplify maintenance and fault isolation in crowded switchgear bays, speeding diagnostics and reducing downtime during upgrades in telecom, data center, and factory environments. TMF release delivers targeted protection against overloads, improving system reliability and extending the service life of transformers and motors in high-demand applications. Feature → Business Impact → Application: 35 A nominal current with a 125 A rated operating current and a 400 A instantaneous setting supports precise coordination in distribution feeders and motor circuits, enabling tighter protection without unnecessary trips. The XT2 4P configuration with front-terminal bolt connections and a 6 N·m tightening torque enables solid, vibration-resistant installation in equipment racks and panel boards. Feature → Business Impact → Application: Busbar connections from 32.5 to 100 mm² provide flexible phasing and future upgrade options for scalable power distribution. Feature → Business Impact → Application: RoHS and REACH declarations plus CMRT and EPD documentation give compliance teams confidence for regulated markets and sustainability reporting. The UL489 and CSA certifications, along with CE conformity, streamline procurement and minimize supplier risk by ensuring compatibility with US, Canadian, and international standards. Feature → Business Impact → Application: End-of-life disassembly instructions and recycling guidance support sustainable disposal programs in aerospace, automotive, and process industries.
Get a Quick Quote for a ABB 1SDA074807R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA074807R1?
Enquire Now
FAQs
This 4P unit uses front-terminal bolt connections with a recommended tightening torque of 6 N·m. It supports busbar sizes from 32.5 to 100 mm², and the mounting is designed for compact panel layouts. Ensure busbar alignment and proper clearance for maintenance access, while following the XT2 wiring diagram and installation instructions for UL/CSA compliance.
The Ii setting at 400 A provides fast, selective tripping for high-energy fault events without unnecessary nuisance trips on normal inrush. Combined with TMF release and a 35 A nominal current, this enables coordinated protection for feeders and motors while preserving downstream equipment, reducing unplanned outages and asset wear.
Yes. The 4P XT2 device supports 600 V operation, front-terminal installation, and robust interrupting ratings per UL489. Its compact footprint and 1.45 kg weight simplify panel integration, and its compatibility with SACE Tmax XT families ensures scalable protection across multiple switchgear configurations in manufacturing, process industries, and data centers.
The unit carries UL489 and CSA certifications, a CE Declaration of Conformity, RoHS and REACH declarations, CMRT, TSCA, and an EPD. This combination supports regulatory compliance in North American and European markets, sustainability reporting, and responsible sourcing in procurement workflows.
The device offers 8,000 electrical cycles and 25,000 mechanical cycles, contributing to long service life and reduced maintenance. Front-terminal design minimizes wiring complexity during inspections, while documented end-of-life and recycling guidance supports asset lifecycle management and potential cost savings through extended downtime between replacements.