ABB 1SDA074810R1 is a four-pole molded case circuit breaker designed for reliable protection in industrial power distribution. Engineers and procurement teams often struggle with front-terminal access, compact footprint constraints, and strict UL/CSA compliance timelines. This XT2H device carries UL489 and CSA certifications, a CE Declaration of Conformity, plus an Environmental Product Declaration and end-of-life disassembly guidance to support sustainable sourcing. Designed for SACE Tmax XT families, it delivers robust protection with straightforward wiring and predictable maintenance, helping reduce downtime and total cost of ownership in panel builds. With 60 A nominal current, 600 V ratings, and front-terminal 4P configuration, it fits common industrial feeders while enabling efficient field service. Compatibility with busbar 32.5–100 mm² and a 6 N·m tightening torque ensures reliable, repeatable installations across new constructions and retrofits.
Product Information
Extended Description
1SDA074810R1 ABB: C.BREAKER TMAX XT2H 125 UL/CSA FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 60-600 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HU4060AFF000XXX
EAN
8015644787875
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.55 kg
Package Level 1 EAN
8015644787875
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT2 4p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.4 W
Rated Current (In)
60 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
600 A
Rated Operational Voltage
600 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
60 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 150 kA | (480 V AC) 65 kA | (600 V AC) 25 kA | (250 V DC) 2 Poles in Series 65 kA | (500 V DC) 3 Poles in Series 65 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3906
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
UL Certificate
1SDL000163R0112
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT2 UL | Release assembly XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Front-terminal, fixed four-pole XT2 design simplifies wiring and front-access installation, reducing assembly time and the risk of misconnection in control panels. The TMF release option offers precise trip coordination, improving fault clearance performance in busy switchgear environments. Electrical ratings deliver predictable protection: rated current 60 A and rated voltage 600 V enable reliable service in standard industrial feeders. The device supports a high instantaneous setting of 600 A and an uninterrupted current of 125 A, helping maintain continuity during transient events. Durability and lifecycle are engineered for busy production floors: electrical durability rated at 120 cycles per hour with 8,000 total cycles and mechanical durability of 240 cycles per hour with 25,000 cycles, ensuring reliable operation across long service lives. Compliance and sustainability are integrated: UL489 and CSA certifications, CE Declaration of Conformity, EPD, and recyclability targets align with global procurement standards. ABB EcoSolutions and end-of-life guidance support responsible disposal and resource recovery. Installation and compatibility advantages: part of the SACE Tmax XT family with busbar connection 32.5–100 mm², a recommended M6 screwdriver, and a 6 N·m tightening torque; this standardization reduces tools needed and ensures repeatable field installations.
Get a Quick Quote for a ABB 1SDA074810R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA074810R1?
Enquire Now
FAQs
This unit uses front terminals suitable for front-facing wiring in compact panels. Plan for a busbar connection range of 32.5–100 mm² and ensure a tightening torque of 6 N·m with an M6 screwdriver. The four-pole configuration requires correct alignment in panel cutouts and adherence to mounting clearances per XT2 specifications.
Key specs include a rated current IN of 60 A, rated voltage UR of 600 V (AC), Ii of 600 A, and Iu of 125 A. The device is rated for UL489/CSA, with a short-circuit interrupting capability listed at 150 kA (240 V AC) and 65 kA (480/600 V AC) per UL489, plus DC ratings as noted in the TSCA/CMRT documentation.
Yes. It carries UL489 and CSA certifications, a CE Declaration of Conformity, and associated DoC documentation. Additional compliance materials include RoHS declarations, CMRT, TSCA, and an Environmental Product Declaration (EPD), supporting regulatory alignment across global markets and sustainable procurement programs.
Product net dimensions are 120 mm wide, 130 mm high, and 82.5 mm deep, with a net weight of 1.45 kg. Packaged dimensions and packaging weight are provided for logistics planning (box packaging listed as 1 piece per box, 131 mm width, 212 mm height, 147 mm depth, and 1.55 kg gross). This aids rack design and enclosure sizing.
Best used in industrial power distribution, panel boards, motor feeders, and switchgear within SACE Tmax XT family deployments. Its 4P front-terminal configuration and TMF release support reliable protection for distributed loads, with 60 A current ratings and 600 V ratings suitable for typical factory and infrastructure feeder schemes.