ABB 1SDA074885R1 Moulded Case Circuit Breaker - UL/CSA
Part Number: 1SDA074885R1
Quick Summary
ABB 1SDA074885R1 Moulded Case Circuit Breaker protects main busbars in electrical panels. Engineers often struggle to balance a compact footprint with reliable short‑circuit protection in demanding environments. UL489/CSA certification and CE conformity help ensure regulatory compliance, while RoHS and REACH declarations support sustainable manufacturing practices. By aligning with the SACE Tmax XT family, this device delivers plug‑and‑play compatibility and faster commissioning, delivering safer motor and transformer protection in industrial plants and control panels. This translates to reduced downtime, safer maintenance, and lower lifecycle costs for critical automation infrastructure.
Product Information
Extended Description
1SDA074885R1 ABB: C.BREAKER TMAX XT2H 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MCP Iu 30 A I3=90...330 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HU3030MFF000XXX
EAN
8015644788629
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.2 kg
Package Level 1 EAN
8015644788629
Circuit Breaker Type to be Associated
Motor Protection
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 3.8 W
Rated Current (In)
30 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
90…330 A
Rated Operational Voltage
600 V AC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
MA
Release Type
M
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 150 kA | (480 V AC) 65 kA | (600 V AC) 25 kA | (250 V DC) 2 Poles in Series 65 kA | (500 V DC) 3 Poles in Series 65 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3906
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
UL Certificate
9AKK108467A6479
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT2 UL | Release assembly XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Three-pole XT2H 125 MCP with Iu 125 A and Ii 90–330 A enables precise, reliable protection for transformers and motors, reducing unscheduled downtime in heavy industry. Application: Install in panelboards where front-terminal access streamlines maintenance and testing, saving labor time during commissioning and servicing. Feature → Front terminals and fixed mounting simplify wiring and improve reliability with consistent torque (6 N·m) and robust bolt-type connections; reduces field errors and rework. Application: Suitable for tight spaces in switchgear and machinery racks where serviceability matters. Feature → Rated voltage 600 V and AC/DC compatibility support broader industrial uses, including mixed-voltage motor drives; Business Impact: improves protection strategy across diversified automation lines. Application: Transformer protection and feeder protection in manufacturing lines. Feature → 3P design with MA/M release and 30 A nominal current (In=30 A); Business Impact: predictable trip behavior, easier coordination with upstream protection; Application: Main protection in MCCs and switchgear. Feature → High short-circuit ratings per UL489 (up to 150 kA at 240 V, 65 kA at 480 V, 25 kA at 600 V) ensures safe interruption of faults; Application: Critical feeders and transformer protections in high‑energy environments. Feature → Power loss of 3.8 W per pole and mechanical durability up to 25,000 cycles; Business Impact: lower heat generation and longer life in continuous duty; Application: Frequent cycling applications such as motor control centers. Feature → EcoSolutions and Recyclability (55.70% EN45555) support sustainability targets; Application: End-of-life planning and compliant disposal in modern plants. Feature → RoHS/REACH and CMRT declarations ensure regulatory compliance across regions; Application: Global deployments with minimal compliance risk.
Get a Quick Quote for a ABB 1SDA074885R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA074885R1?
Enquire Now
FAQs
This MCCB uses front terminals with bolt connections (Bolt type) and requires a 6 N·m tightening torque. It is designed for busbar connections in the range of 32.5 to 100 mm² and accepts a Main Circuit M6 screwdriver. With dimensions of 90 mm width, 130 mm height, and 82.5 mm depth, ensure enclosure clearance for front access and serviceability. The 3P fixed configuration supports straightforward mounting and alignment to standard panel cutouts.
The device is a 3P molded case circuit breaker with In = 30 A, Up to 600 V rated voltage, and a rated uninterrupted current Iu = 125 A. The instantaneous short-circuit setting Ii ranges from 90 to 330 A, with a release MA and M-type trip. It conforms to UL489 and CSA CS22.2 standards, ensuring reliable interruption and protection coordination in industrial power systems.
Yes. The XT2 family provides motor protection and feeder protection suitable for transformers and heavy machinery. With a 3P configuration, front terminals for easy maintenance, and a 600 V operating voltage, it integrates with transformer and motor circuits in control panels. Its compact footprint and fast trip response reduce arc exposure and downtime, improving overall line protection.
This MCCB carries UL489 compliance with a UL Certificate (9AKK108467A6479) and CSA certification (Intrinsic Safe). It also features a CE Declaration of Conformity, RoHS and REACH declarations, CMRT data, and an EPD for the Tmax XT family. Technical data sheets and installation instructions are provided, including disassembly guidance for end‑of‑life handling.
The device delivers a mechanical durability rating of up to 25,000 cycles and electrical durability around 8,000 cycles per hour, supporting frequent operation in motor control centers. Front-terminal design reduces wiring time during replacement, and 6 N·m torque ensures consistent connections. End‑of‑life disassembly instructions and high recyclability support lower lifecycle costs and easier asset retirement.