ABB 1SDA074887R1 Moulded Case Circuit Breaker - UL/CSA
Part Number: 1SDA074887R1
Quick Summary
ABB 1SDA074887R1 Moulded Case Circuit Breaker provides reliable overload and short-circuit protection for industrial power distribution. For panel builders and maintenance teams, dense wiring and tight spaces can complicate installation; this unit's three-pole, front-terminal design simplifies wiring layout, reduces commissioning time, and improves serviceability. It carries UL489 and CSA certifications with CE conformity, plus RoHS and WEEE considerations, and ABB EcoSolutions lifecycle guidance to support responsible sourcing. The integration with the SACE Tmax XT platform enables predictable performance, easy integration with ABB components, and simplified procurement through standardized specifications. In practice, you gain improved protection reliability, shorter downtime, and lower total cost of ownership for industrial automation projects.
Product Information
Extended Description
1SDA074887R1 ABB: C.BREAKER TMAX XT2H 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MCP Iu 70 A I3=210...770 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HU3070MFF000XXX
EAN
8015644788643
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.2 kg
Package Level 1 EAN
8015644788643
Circuit Breaker Type to be Associated
Motor Protection
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 5.5 W
Rated Current (In)
70 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
210…770 A
Rated Operational Voltage
600 V AC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
MA
Release Type
M
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 150 kA | (480 V AC) 65 kA | (600 V AC) 25 kA | (250 V DC) 2 Poles in Series 65 kA | (500 V DC) 3 Poles in Series 65 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3906
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
UL Certificate
9AKK108467A6479
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT2 UL | Release assembly XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal bolt connections enable straightforward wiring and safer maintenance. Business Impact: Reduces wiring errors and speeds up commissioning in control panels. Application: Ideal for compact panels in process automation where quick serviceability matters. Feature: Rated current In of 70 A with a rated operational voltage of 600 V AC provides robust protection for medium-sized feeders. Business Impact: Ensures precise protection for motors, transformers, and distribution circuits while maintaining energy efficiency. Application: Suitable for machine rooms and automation racks with moderate load profiles. Feature: Rated instantaneous short-circuit current Ii of 210–770 A and Iu of 125 A improves selective coordination. Business Impact: Improves fault clearance speed and minimizes downstream disruption, reducing downtime costs. Application: Essential in panels with multiple protection layers and transformer feeders. Feature: Front-terminal design supports tool-assisted installation and easy wire routing, aided by a recommended M6 main circuit screwdriver and a 6 N·m tightening torque. Business Impact: Streamlines assembly and ensures secure terminations, reducing revisit calls. Application: Works well in new builds and panel refurbishments. Feature: ABB EcoSolutions and End Of Life guidance, including an Environmental Product Declaration (EPD) and a recyclability rate of 55.70% per EN45555. Business Impact: Supports sustainable procurement, regulatory compliance, and lifecycle cost reduction. Application: Beneficial for green building projects and organizations pursuing circular economy targets.
Get a Quick Quote for a ABB 1SDA074887R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA074887R1?
Enquire Now
FAQs
Yes. The device supports busbar conductors in the 32.5 to 100 mm² range and uses front-terminal bolt connections designed for easy, safe wiring. A recommended M6 screwdriver and a tightening torque of 6 N·m ensure secure terminations. This configuration simplifies routing in tight panels and reduces commissioning time.
The MCCB is rated for 70 A and 600 V, with a rated uninterrupted current (Iu) of 125 A. It provides a rated instantaneous short-circuit current setting (Ii) from 210 to 770 A. It is a 3-pole device (3P) with front-terminal connections and a 60 Hz operating context compatible with UL489 and CSA CS22.2 standards.
Yes. Labeled to support motor protection within the SACE Tmax XT family, the XT2 3P MCCB provides motor feeder protection with fast fault clearing and selective tripping. Its 6 N·m torque and front-terminal design ease motor-install environments, while the Ii range supports motor inrush and short-circuit protection without nuisance tripping.
The unit complies with UL489 and CSA CS22.2 standards, with a CE Declaration of Conformity and RoHS compliance. Additional support materials include the EPD under ABB EcoSolutions, disassembly instructions for end-of-life handling, and CMRT for conflict minerals reporting, aligning with broader regulatory and sustainability requirements.
Lifecycle value comes from reliable protection, reduced downtime, and easier maintenance due to front-terminal wiring and standardized ABB components. The product features documented End Of Life instructions, an environmental profile (EPD), and recyclability guidance (55.70%), aiding procurement decisions and long-term cost-of-ownership planning in automation facilities.