ABB 1SDA074975R1 Moulded Case Circuit Breaker - UL/CSA XT2

Part Number: 1SDA074975R1
Manufacturer
ABB
Part number
1SDA074975R1

Quick Summary

ABB 1SDA074975R1 is a 4-pole molded case circuit breaker designed for reliable protection in industrial distribution panels. Engineers often struggle with front-terminal accessibility and consistent trip performance under fault conditions. UL489 and CSA certifications, CE Declaration of Conformity, and RoHS compliance support global deployment. In practice, the unit integrates with SACE Tmax XT families and Ekip LSI releases to streamline front-terminals installation and lifecycle maintenance, delivering safer, more compliant power protection for industrial facilities. This model’s 10 A rated current, 690 V AC operation, and 4P configuration support compact, scalable protection in critical plant sections. With front-terminal connections and a robust 6 N·m tightening torque, installation is fast and serviceable.

Product Information

Extended Description

1SDA074975R1 ABB: C.BREAKER TMAX XT2H 125 UL/CSA FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LSI R 10 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HU4010FFF000XXX
EAN
8015644789527
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.6 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.6 kg
Package Level 1 EAN
8015644789527
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT2 4p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 0.10 W
Rated Current (In)
10 A
Rated Frequency (f)
50/60 Hz
Rated Insulation Voltage (Ui)
1000 V AC
Rated Operational Voltage
690 V AC
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V AC
Recommended Screw Driver
Main Circuit M6
Release
Ekip LSI
Release Type
EL
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 150 A | (480 V AC) 65 A | (600 V AC) 25 A
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3906
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
UL Certificate
1SDL000163R0112
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT2 UL | Ekip C Dip LSI, Ekip C Dip LSIG and LIG XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4934 >> 4 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: 4P XT2 design with front-terminal connections enables rapid wiring and safer maintenance. Business impact: reduces commissioning time and limits human errors during terminations, translating into fewer field faults and smoother startup of critical lines. Application: ideal for SACE Tmax XT installations in distribution panels across manufacturing and process industries. Feature: Rated 10 A In, 690 V AC and front-accessible terminals support broad compatibility with feeders and transformers, reducing mis-sizing risk and enabling modular expansion in growing facilities. Application: motor control centers and panel boards requiring reliable protection with scalable current ratings. Feature: Ekip LSI release provides selective tripping and enhanced protection coordination. Business impact: minimizes nuisance trips, improves safety margins, and simplifies maintenance planning. Application: essential in critical power distribution for process lines and data-center-style environments. Feature: Front terminals with 6 N·m tightening torque deliver robust, serviceable mounting and straightforward field replacement. Business impact: accelerates service events and reduces torque-related connection issues. Application: convenient for installations with tight access in compact switchgear, including transformer protection panels. Feature: Compliance and environmental attributes include RoHS, REACH, EPD support, and recyclability considerations. Business impact: eases regulatory approvals and supports sustainable end-of-life management in line with corporate ESG goals. Application: suitable for global deployments across manufacturing, energy, and infrastructure projects.

Get a Quick Quote for a ABB 1SDA074975R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA074975R1? Enquire Now

FAQs

ABB 1SDA074975R1 is designed for 4-pole Tmax XT panels with front-terminal wiring. It supports busbar connections from 32.5 to 100 mm², uses a bolt terminal type, and requires 6 N·m tightening torque. This configuration enables quick wiring, safer maintenance, and scalable protection in distribution boards and switchgear in manufacturing facilities.
The device is rated for 10 A nominal current (In) and operates at 690 V AC with 50/60 Hz. It is UL489 and CSA listed, with CE declaration of conformity and RoHS/REACH compliance. Its interruption ratings at UL489 include 150 A at 240 V, 65 A at 480 V, and 25 A at 600 V, suitable for medium fault currents in industrial panels.
Yes. The 4P XT2 MCCB with Ekip LSI release is designed for transformer protection and general power distribution in industrial facilities. Its front-terminal design, robust tripping, and high insulation voltage enable safe, reliable protection in switchgear and feeder panels, while the Ekip LSI release improves selective coordination and reduces nuisance trips.
This MCCB carries UL489 and CSA certifications, with a CE Declaration of Conformity. It is RoHS and REACH compliant, supported by additional environmental documentation such as the EPD for Tmax XT XT2 ELT and recycling data. CMRT and TSCA declarations are also referenced where applicable, aiding global regulatory compliance and responsible sourcing.
Maintenance benefits include front-terminal accessibility for quick inspections, a documented tightening torque of 6 N·m to ensure reliable connections, and an Ekip LSI release that improves protection coordination. With 0.10 W power loss per pole under rated conditions and an extended lifecycle, this unit can lower energy and downtime costs while delivering safer, compliant protection.