ABB 1SDA075022R1 Moulded Case Circuit Breaker - UL/CSA

Part Number: 1SDA075022R1
Manufacturer
ABB
Part number
1SDA075022R1

Quick Summary

ABB 1SDA075022R1 Moulded Case Circuit Breaker protects low-voltage distribution panels and transformer feed lines in industrial switchgear. This device delivers reliable overcurrent protection for 3P XT2 configurations while supporting front-terminal installations for streamlined wiring. Engineers often face the challenge of fitting high protection performance into compact footprints without compromising compliance. The model adheres to UL489 and CSA CS22.2 standards, and it also carries CE conformity, RoHS, and REACH declarations, with an Environmental Product Declaration (EPD) for sustainable design. By aligning with SACE Tmax XT families and Ekip LSIG release technology, it supports safer, more efficient panel builds and long-term maintenance readiness, delivering value through reduced risk and predictable operating costs.

Product Information

Extended Description

1SDA075022R1 ABB: C.BREAKER TMAX XT2H 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LSIG R 60 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
b8f6e917-89be-4d0a-b7a9-05f7888f2572 Italy (IT)
Simplified SCIP
184fe20e-7be5-42b1-aa16-210317bb44e5 Hungary (HU) | abc6eb58-ad21-40b9-8587-4d66e430e4bb Norway (NO) | 08805939-8534-4704-b0b5-0352fae9798a Poland (PL) | db588461-5143-4d89-881a-d796b4d60a3c Belgium (BE) | 5f63cec6-674d-4470-bbcc-06fab831927a Germany (DE) | 7f5e773e-902a-4c86-ac2d-8f78bc9f9d86 Spain (ES) | c58c7441-d4c0-4c2d-bc96-0f4fd1a0f74d Sweden (SE) | c1655dff-1bd3-46e9-913e-e72071150650 Poland (PL) | 44eb6a63-2f7d-41d6-a0e9-3da1785d11e3 France (FR) | 8a7cd902-518b-4a4e-9f49-faf091381d3f Germany (DE) | 169202a8-c460-421c-990a-554440e16400 Germany (DE) | 7d2982bb-938f-42c7-86c7-4b36bc3ea999 Belgium (BE) | ab9b7189-f47f-435c-9ca0-d7d080b5214b Hungary (HU) | 3318aac9-a7e3-4ffc-9a35-f48b0759b40f Bulgaria (BG) | eab84be9-d99d-4f56-b638-edd286a79d7f Greece (GR) | f373f1a0-8c64-4081-b766-2369c7655e2d Portugal (PT) | 4db3960a-d772-47dc-8565-82500d729c41 Denmark (DK) | 9d7ca472-a973-4233-a337-27f17442a413 Germany (DE) | 8630aa0d-5b30-4c18-a72b-e3f938402666 Czech Republic (CZ) | 4748ba47-b165-4823-8d8c-d72366a64e17 Poland (PL) | fc8323d8-5190-4ff4-909f-41880550d14f Estonia (EE) | 4219cc11-cdc3-40a4-938d-983f8c235f42 Finland (FI) | a786afa3-6bac-4d3f-8d7c-c54ff5b683c8 Germany (DE) | c7d54a0c-df25-4de1-95ae-7c60df3bc652 Netherlands (NL) | 235ecdce-e277-40fb-9ed4-d57bda001c33 Croatia (HR) | ab5a02f3-3ab2-417a-b7aa-1b41d1c98820 Sweden (SE) | 2328494f-5bcd-40a6-8d49-89bfb2a03cc1 France (FR)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HU3060GFF000XXX
EAN
8015644789992
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.2 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.22 kg
Package Level 1 EAN
8015644789992
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.50 W
Rated Current (In)
60 A
Rated Frequency (f)
50/60 Hz
Rated Insulation Voltage (Ui)
1000 V AC
Rated Operational Voltage
690 V AC
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V AC
Recommended Screw Driver
Main Circuit M6
Release
Ekip LSIG
Release Type
EL
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 150 A | (480 V AC) 65 A | (600 V AC) 25 A
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3906
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
UL Certificate
1SDL000163R0112
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT2 UL | Ekip C Dip LSI, Ekip C Dip LSIG and LIG XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Front-terminal, fixed 3P construction simplifies wiring and reduces installation time, lowering labor costs while improving reliability in dense switchgear layouts for regional distribution boards and motor feeder panels. Feature → Application: Ekip LSIG release offers fast, selective tripping with precise coordination, minimizing downtime in critical automation areas and enabling safer startup sequences for packaging lines or process control systems. Feature → Business Impact → Application: 60 A rated current with 690 V AC operational voltage supports common industrial motor and transformer protection schemes, enabling compliant protection in metal-clad panels and energy distribution networks. Feature → Application: 32.5 to 100 mm² busbar connections provide flexible wiring options for copper bar sizes, improving connection integrity and reducing duplicate parts or extensions in retrofits. Feature → Business Impact → Application: Fixed front terminals and 6 N·m tightening torque streamline assembly checks and torque audits, boosting quality control in high-volume panel manufacturing. Feature → Application: RoHS, REACH and SCIP declarations, along with UL489/CSA CS22.2 approvals, simplify regulatory documentation for global projects and reduce sourcing risk in multinational deployments.

Get a Quick Quote for a ABB 1SDA075022R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA075022R1? Enquire Now

FAQs

This 3P fixed-front-terminal breaker uses front connection bolts with a tightening torque of 6 N·m. It supports busbars from 32.5 to 100 mm², and dimensions of W90 x H130 x D82.5 mm, making it suitable for compact switchgear and panel enclosures. Ensure proper clearance for front-access wiring and torque calibration during commissioning.
Yes. The device is designed for UL489 and CSA CS22.2 compliance, backed by UL certificate 1SDL000163R0112 and CSA certificate 9AKK10103A3906, with a CE declaration of conformity. This combination supports global deployment in electrical installations requiring recognized safety and performance benchmarks.
Electrical durability is rated at 120 cycles per hour and 8000 cycles total, while mechanical durability covers 240 cycles per hour and up to 25000 cycles. These ratings translate to robust lifecycle performance in demanding industrial environments such as continuous process lines and material handling.
Ideal for power distribution and motor feeder protection within SACE Tmax XT installations, including transformer and generator protection schemes. Its 60 A rating and 690 V AC capability align with common industries like manufacturing, oil & gas, and chemical processing, where reliable short-circuit protection and safe disconnection are critical.
In addition to UL489/CSA CS22.2, the product offers CE conformity, RoHS and REACH declarations, and an Environmental Product Declaration (EPD). SCM/CMRT data and SCIP status support sustainability reporting, while packaging and ordering details (MOQ 1 piece, EAN 8015644789992, Order Code XT2HU3060GFF000XXX) aid procurement and traceability.