ABB 1SDA075070R1 Moulded Case Circuit Breaker - UL/CSA

Part Number: 1SDA075070R1
Manufacturer
ABB
Part number
1SDA075070R1

Quick Summary

ABB 1SDA075070R1 is a moulded case circuit breaker designed for reliable protection of electrical feeders in industrial control panels. In demanding environments, teams face nuisance trips, slow fault isolation, and costly downtime when safeguarding power distribution. This XT2-based device carries CE conformity and UL/CSA listings, plus a CSA intrinsic safe certificate, ensuring regulatory compliance across European and North American installations. The combination of front-terminal wiring, compact 3P form, and a 10 A rated current supports streamlined installation and maintenance. By leveraging ABB EcoSolutions, customers achieve lower total cost of ownership through recyclability, responsible end-of-life handling, and actionable environmental data, while maintaining robust protection in machine lines and process systems.

Product Information

Extended Description

1SDA075070R1 ABB: C.BREAKER TMAX XT2H 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP M DIP I R 10 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HU3010JFF000XXX
EAN
8015644790479
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.12 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.22 kg
Package Level 1 EAN
8015644790479
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 0.1 W
Rated Current (In)
10 A
Rated Operational Voltage
600 V AC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
Ekip M Dip I
Release Type
EL
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 150 kA | (480 V AC) 65 kA | (600 V AC) 25 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3906
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
UL Certificate
1SDL000163R0112
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT2 UL | Release Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal, three-pole XT2 MCCB design with busbar compatibility simplifies wiring and reduces installation time. Business impact: Faster commissioning, fewer field wiring errors, and easier preventive maintenance in control panels. Application: Ideal for machine feeders and distribution blocks in automated lines. Feature: Release option Ekip M Dip I and UVR variants provide selective, reliable tripping with fast response. Business impact: Enhanced protection against short circuits and nuisance trips, improving plant safety and uptime. Application: Critical in conveyor systems, presses, and robotics where precise protection timing matters. Feature: Rated current 10 A, rated voltage 600 V, and UL489/CSA compliance deliver clear operating limits. Business impact: Predictable current limiting, reduced insulation stress, and straightforward integration with standard panel designs. Application: Low-to-medium power distribution within SACE Tmax XT lineage. Feature: High interrupting ratings (UL/CSA as specified) and front-terminal, bolt connection support robust fault handling with safe, accessible wiring. Business impact: Lower fault consequence risk and simplified field repairs in dense electrical rooms. Application: Panel boards and switchgear where space is at a premium. Feature: Low power loss (0.1 W per pole) and compact footprint reduce energy waste and heat rise in cabinets. Business impact: Measurable energy efficiency gains, cooler enclosure environments, and longer component life. Application: Continuous process lines with tight thermal budgets. Feature: EcoSolutions alignment, EPD and recyclability data (55.70% design for closing resource loops) support sustainable procurement. Business impact: Regulatory compliance with environmental standards and improved ESG reporting. Application: Global projects seeking responsible supply chain attributes. Feature: Detailed technical data (busbar 32.5–100 mm², tightening torque 6 N·m, front terminals) ensures correct mounting and dependable performance. Business impact: Consistent installation quality, reduced rework, and clear maintenance guidance. Application: New builds and panel refurbishments requiring standardized components.

Get a Quick Quote for a ABB 1SDA075070R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA075070R1? Enquire Now

FAQs

This MCCB features front terminals and bolt-type connections designed for compact panel layouts. It supports busbars from 32.5 to 100 mm² and requires a tightening torque of 6 N·m, which helps ensure a secure, vibration-resistant connection. The front-access design simplifies alignment during panel assembly and allows quicker fault isolation during commissioning or maintenance.
The device is rated for 10 A at 600 V and provides high interrupting capabilities: (240 V AC) 150 kA, (480 V AC) 65 kA, and (600 V AC) 25 kA. These ratings enable robust protection for downstream circuits, minimizing arc energy impacts and enabling safer maintenance procedures in industrial environments.
Yes. It carries CE declarations of conformity and UL/CSA listings, supported by a UL certificate (1SDL000163R0112) and a CSA certificate (Intrinsic Safe) 9AKK10103A3906. Additional documentation includes the product data sheet and installation instructions, ensuring installers can verify compatibility with UL489 and CSA CS22.2 standards.
The XT2 family is designed for machine control panels, distribution boards, and feeder protection in industrial automation. The 3P configuration with front terminals suits compact switchgear and panel environments, while compatibility with SACE Tmax XT components supports scalable protection schemes and consistent maintenance practices across legacy and new installations.
ABB EcoSolutions provides environmental data, including an EPD for Tmax XT XT2 ELT and a recyclability rate of 55.70% (EN45555). The unit is designed for disassembly at end of life, with packaging disposal guidance and a defined disposition pathway aligning with corporate sustainability goals. Planning should include end-of-life recycling and proper disposal per local regulations to maximize resource recovery.