ABB 1SDA075138R1 Moulded Case Circuit Breaker - UL/CSA
Part Number: 1SDA075138R1
Quick Summary
ABB 1SDA075138R1 Moulded Case Circuit Breaker provides reliable overcurrent protection for industrial power distribution systems. In demanding facilities, rapid fault isolation and compact wiring are critical to uptime. This XT3S 225 TMF unit offers UL/CSA approvals and CE declarations, along with RoHS and REACH compliance, reinforcing safe, sustainable operation. The product integrates seamlessly with SACE Tmax XT families, delivering scalable protection for transformers, MCCs, and motor feeders. By combining front-terminal accessibility with robust performance, it reduces panel space requirements and simplifies maintenance, helping engineers meet regulatory and budget targets without compromising protection.
Product Information
Extended Description
1SDA075138R1 ABB: XT3S 225 TMF 225-2250 3p F F UL/CSA
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT3
Environmental Product Declaration - EPD
EPD Tmax XT XT3 (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 56.6 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT3SU3225AFF000XXX
EAN
8015644791155
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
105 mm
Product Net Height
150 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.7 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
155 mm
Package Level 1 Height
190 mm
Package Level 1 Depth / Length
155 mm
Package Level 1 Gross Weight
1.7 kg
Package Level 1 EAN
8015644791155
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
XT3 3p FIXED F
Connecting Capacity Main Circuit
Busbar 85..192 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 14.4 W
Rated Current (In)
225 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
2250 A
Rated Operational Voltage
600Y/347 V AC | 500 V DC
Rated Uninterrupted Current (Iu)
225 A
Rated Voltage (Ur)
600Y/347 V
Recommended Screw Driver
Main Circuit M8
Release
TMF
Release Type
TM
Setting Range
225 A
Short-Circuit Performance Level
S
Standards
UL489
Sub-type
XT3
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
8 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA | (480 V AC) 35 kA | (600Y / 347 V AC) 10 kA | (250 V DC) 2 Poles in Series 35 kA | (500 V DC) 3 Poles in Series 35 kA
ATEX Certificate
No certification needed
CSA Certificate (Intrinsic Safe)
9AKK10103A3907
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT3
UL Certificate
1SDL000163R0113
VDE Certificate
No certification needed
Dimension Diagram
XT3 3p-4p fixed front terminals
Mechanical Drawings
XT3 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT3 UL
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The 3-pole XT3S design with 225 A rated current provides precise protection for high-demand distribution paths, reducing fault propagation and ensuring quick isolation in transformer feeders and motor control centers. This translates to measurable uptime improvements and lower downtime costs in manufacturing lines and process facilities. Feature → Application: Front-terminal bolt connections with a recommended M8 screwdriver enable faster, more secure wiring during panel assembly and field retrofits, decreasing installation time and error potential; ideal for retrofit projects in legacy MCCs and new build-outs where space is at a premium. Feature → Business Impact → Application: TMF/TRM release capability supports fast clearing of faults with predictable opening times (30 ms), enhancing system reliability in critical power feeds and reducing arc-flash exposure during maintenance.
Get a Quick Quote for a ABB 1SDA075138R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA075138R1?
Enquire Now