ABB 1SDA075652R1 Accessory - TMF XT2 UL/CSA Certified

Part Number: 1SDA075652R1
Manufacturer
ABB
Part number
1SDA075652R1

Quick Summary

ABB 1SDA075652R1 is an XT series accessory for Tmax XT circuit breakers used in modular power distribution. Engineers often struggle with quick, compliant integration across regions, leading to delays and rework; this accessory simplifies mounting and shunt-release configurations while preserving diagnostic visibility. The solution supports CE conformity, UL/CSA listings, and RoHS compliance to meet global deployment demands. By standardizing interfaces and offering front-access terminals, it reduces installation time and minimizes field rework, delivering lower total cost of ownership. Distributors and maintenance teams benefit from predictable XT component compatibility and streamlined stocking in the Tmax XT ecosystem.

Product Information

Extended Description

1SDA075652R1 ABB: TMF 70-700 3p F F XT2 3p UL/CSA
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8015644796297
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
0.8 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
145 mm
Package Level 1 Height
75 mm
Package Level 1 Depth / Length
95 mm
Package Level 1 Gross Weight
0.9 kg
Package Level 1 EAN
8015644796297
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT2
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
3P
Order Multiple
1 piece
Rated Current (In)
70 A
Release
TMF
Release Type
TM
Standards
UL489
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT2-XT4
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Feature: Loose or configurable configuration. Business Impact: Flexible installation paths reduce SKU proliferation and speed up on-site deployment. Application: XT2 power distribution setups where rapid customization is essential. Feature: 3P, AC/DC, 70 A rated current. Business Impact: Supports demanding industrial loads with reliable performance, minimizing nuisance trips. Application: 70 A Tmax XT line side circuits in manufacturing lines. Feature: Front terminal connection (Fixed Circuit-Breakers | Front). Business Impact: Safer, quicker wiring and easier maintenance with reduced downtime. Application: Routine inspection and replacement tasks in compact switchgear layouts. Feature: UL489/CSA compliance and RoHS/TSCA declarations. Business Impact: Ensures regulatory alignment and sustainable material handling, simplifying audits. Application: Global deployments requiring standard certifications. Feature: Product packaging and logistics data (1 piece MOQ, EAN 8015644796297, weight 0.8 kg). Business Impact: Streamlined procurement and accurate inventory planning. Application: Distributor fulfillment and BOM integration. Feature: Product type and compatibility notes (SACE Tmax XT, Suitable for XT2). Business Impact: Clear integration path minimizes compatibility risk. Application: System designers selecting accessories for XT2 configurations.

Get a Quick Quote for a ABB 1SDA075652R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA075652R1? Enquire Now

FAQs

Start by verifying XT2 compatibility and the accessory's loose or configurable mounting option. Switch off power, remove the front cover if required, and align the accessory with the Tmax XT bus bars. Connect the front terminals per the SACE Tmax XT technical characteristics, secure fasteners to torque specifications, reassemble, and verify continuity and insulation resistance before commissioning.
Key specs include 3 poles (3P), AC/DC current type, rated current 70 A, and the TMF release type. The accessory uses fixed front-terminal connections, is UL489/CSA certified, RoHS compliant, and designed for XT2. These attributes ensure safe operation, regional compliance, and straightforward installation in standard Tmax XT configurations.
Yes, this accessory is designed for XT2 configurations and belongs to the Tmax XT Accessories product class. It supports SACE Tmax XT systems and is listed as a compatible component for XT2 mounting, shunt release applications, and front-terminal wiring, enabling consistent integration across the Tmax XT family.
The accessory carries UL489 and CSA listings, with CE conformity and RoHS compliance documented. Additional declarations include CMRT (conflict minerals), TSCA, and packaging disposal information. These certifications simplify cross-border approvals and support responsible material sourcing throughout the product lifecycle.
Using this ABB accessory reduces on-site wiring time, minimizes mis-wiring errors, and speeds regulatory approvals, which lowers installation labor costs and downtime. The predictable interface and standardized XT2 compatibility also simplify spare-parts planning and reduce total cost of ownership over the system's lifecycle.