ABB 1SDA075665R1 Accessory for Tmax XT Shunt Release UL/CSA

Part Number: 1SDA075665R1
Manufacturer
ABB
Part number
1SDA075665R1

Quick Summary

ABB 1SDA075665R1 is an accessory for SACE Tmax XT enabling front-mounted shunt release in four-pole assemblies. This solution addresses installation complexity, wiring density, and coordination between main breakers and control circuits by providing a compact, front-accessible mounting option. The product carries UL489/CSA certification, CE conformity, and RoHS/REACH compliance, with TSCA and CMRT declarations supporting responsible sourcing and regulatory audits. Designed for XT2-compatible installations and the broader Tmax XT ecosystem, it helps OEMs and panel builders reduce field labor, minimize error-prone wiring, and accelerate commissioning—delivering predictable performance and lower total cost of ownership.

Product Information

Extended Description

1SDA075665R1 ABB: TMA 110-550..1100 4p F F XT2 4p UL/CSA
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8015644796426
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
145 mm
Package Level 1 Height
75 mm
Package Level 1 Depth / Length
95 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644796426
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT2
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
4P
Order Multiple
1 piece
Rated Current (In)
110 A
Release
TMA
Release Type
TM
Standards
UL489
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT2-XT4
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Feature: Four-pole AC/DC configuration and four-pole mounting alignment. Business Impact: Enables precise fitment within SACE Tmax XT assemblies, reducing gaps in coordination between the main circuit breaker and shunt release while supporting XT2 compatibility. Application: Suitable for four-pole XT2 panels in distribution networks, data centers, and industrial controls. Feature: Front-terminal connection type. Business Impact: Frees space inside enclosures, simplifies wiring, and shortens installation time with direct-access terminals. Application: Ideal for restricted retrofit spaces and new panel builds where fast commissioning is critical. Feature: 110 A rated current with TM/TMA release. Business Impact: Supports typical distribution loads without oversizing, lowering total cost of ownership while maintaining protective coordination. Application: Power distribution sections and MCCs requiring reliable shut-off control. Feature: Loose or configurable configuration option. Business Impact: Offers on-site customization to match existing architectures, reducing retrofit risk and post-install adjustments. Application: Field upgrades and modular panel designs in industrial environments. Feature: Comprehensive regulatory and material compliance. Business Impact: Simplifies procurement, audit readiness, and sustainability reporting with UL489, RoHS, REACH, TSCA, and CMRT documentation. Application: Regulated installations in automotive, data centers, and critical infrastructure where traceability matters.

Get a Quick Quote for a ABB 1SDA075665R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA075665R1? Enquire Now

FAQs

When installing 1SDA075665R1, ensure a four-pole fit for the XT series and use the front-terminal connection to minimize enclosure depth. Verify that the XT2 configuration is appropriate for your panel and confirm compatibility with UL489/CSA standards. Use the 1 piece minimum order for stocking and align with the recommended release assembly XT2-XT4 guidelines to avoid mounting conflicts.
The accessory provides a reliable front-mounted shunt release for four-pole Tmax XT breakers, improving trip coordination and response time in distribution panels. With a 110 A rating and AC/DC compatibility, it supports typical distribution loads while maintaining UL489 compliance. The result is enhanced protection, reduced wiring complexity, and faster commissioning in industrial control environments.
Yes, this accessory is designed for XT2 configurations within the SACE Tmax XT family. It uses a loose or configurable mounting approach and front-terminal connection, simplifying retrofit and field upgrades. Ensure the panel supports four-pole XT2 arrangements and verify UPCs (EAN 8015644796426) and packaging dimensions align with your procurement and space constraints.
The accessory carries UL489 and CSA certifications for low-voltage molded-case breakers, with CE Declaration of Conformity and RoHS/REACH compliance. Additional documentation includes TSCA, CMRT, and WEEE categorization, plus ETIM classifications for shunt release components. This suite supports regulatory audits, supplier qualification, and green manufacturing disclosures.
Using this XT shunt-release accessory can reduce wiring time and field labor, lowering commissioning costs and minimizing human-error risk. Its XT2 compatibility enables smoother upgrades in existing Tmax XT deployments, while UL/CSA and RoHS/REACH compliance simplify procurement and maintenance planning, contributing to faster time-to-operation and improved system reliability.