ABB 1SDA075707R1 Accessory - for Tmax XT4 UL/CSA

Part Number: 1SDA075707R1
Manufacturer
ABB
Part number
1SDA075707R1

Quick Summary

ABB 1SDA075707R1 Accessory is a shunt release module for SACE Tmax XT circuit breakers, delivering fast, controlled tripping in demanding power-distribution environments. In many panel designs, coordination delays and wiring errors can escalate downtime; this accessory mitigates those risks with a robust 3P configuration and front-terminal connections. It carries UL489 certification and a CE declaration of conformity, with RoHS and REACH compliance to support global sourcing. CMRT and TSCA declarations further ease cross-border procurement. By aligning with XT4 compatibility and straightforward installation, the solution supports reliable protection, reduced fault-clearing times, and measurable cost efficiency through simplified maintenance and predictable service routines.

Product Information

Extended Description

1SDA075707R1 ABB: TMA 100 500..1000 3p F F XT4 3p UL/CSA
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8015644796846
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
162 mm
Package Level 1 Height
92 mm
Package Level 1 Depth / Length
100 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644796846
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT4
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
3P
Order Multiple
1 piece
Rated Current (In)
100 A
Release
TMA
Release Type
TM
Standards
UL489
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT2-XT4
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
The 3P shunt release design directly translates to improved protection coordination, enabling faster response times and safer shutdown of affected circuits, which minimizes downstream damage and downtime in critical power systems. Its front-terminal, fixed connection simplifies wiring during installation, reducing risk of misconnection and enabling quicker panel upgrades or retrofits. With a rated current of 100 A and AC/DC compatibility, the accessory handles typical industrial loads from motor drives to distribution feeders, delivering consistent performance across varied applications. Compliance with UL489, RoHS, REACH, and CMRT/TSCA ensures regulatory alignment for North American, European, and global projects, easing multi-site deployments and supplier audits. The XT2–XT4 compatibility broadens reuse across existing Tmax XT installations, supporting standardization and lower total cost of ownership. Documentation, manuals, and standard packaging support predictable procurement and maintenance cycles.

Get a Quick Quote for a ABB 1SDA075707R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA075707R1? Enquire Now

FAQs

It is a 3-pole shunt release accessory designed for Tmax XT circuit breakers with front-fixed terminals. It supports loose or configurable mounting and is compatible with XT2 through XT4 families, enabling straightforward retrofits in existing panels. Installation follows standard ABB procedures, minimizing downtime and wiring errors.
The accessory operates with AC or DC control signals, configured for 3 poles, and a rated current of 100 A. It uses a front-terminal connection for reliable wiring and aligns with UL489 standards, ensuring safe, compliant operation within SACE Tmax XT series, including XT4 applications.
It carries UL489 certification and a CE Declaration of Conformity, with RoHS and REACH compliance. Additional documentation includes CMRT and TSCA declarations, enabling cross-market procurement and regulatory audits for global projects.
Yes. The front-terminal, fixed connection design simplifies wiring, and its 3P XT compatibility supports rapid upgrades across XT2–XT4 installations. The device’s compact form, standardized mounting, and clear documentation help shorten commissioning times while improving trip coordination and overall protection performance.
Documentation includes the SACE Tmax XT UL/CSA technical characteristics, release assembly guidance XT2–XT4, and the product data sheet. Additional declarations cover CE conformity, RoHS/REACH compliance, CMRT, and TSCA, along with packaging and EAN details to support procurement, audits, and ongoing maintenance.