ABB 1SDA075710R1 Accessory for Tmax XT - UL/CSA

Part Number: 1SDA075710R1
Manufacturer
ABB
Part number
1SDA075710R1

Quick Summary

ABB 1SDA075710R1 is an XT accessory that enables a reliable shunt release for Tmax XT power distribution panels. Engineers often contend with miscoordination during trips and costly downtime when upgrading legacy equipment. This accessory delivers regulatory confidence with UL489/CSA standards, RoHS compliance under EU directive 2011/65/EU with amendment 2015/863, and a CE declaration. Designed for XT4 compatibility and front-terminal installation, it streamlines commissioning, reduces field wiring errors, and preserves the compact footprint of Tmax XT assemblies. From procurement to service, the solution supports predictable lead times and straightforward stocking, enabling faster project execution and safer, compliant power distribution.

Product Information

Extended Description

1SDA075710R1 ABB: TMA 150 750..1500 3p F F XT4 3p UL/CSA
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8015644796877
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
162 mm
Package Level 1 Height
92 mm
Package Level 1 Depth / Length
100 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644796877
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT4
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
3P
Order Multiple
1 piece
Rated Current (In)
150 A
Release
TMA
Release Type
TM
Standards
UL489
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT2-XT4
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Feature I: Shunt release compatibility with Tmax XT 3P 150 A. Business impact: Improves trip coordination and reduces unexpected downtime in critical power paths. Application: Suitable for XT4 power distribution panels in industrial facilities, data centers, and manufacturing lines. Feature II: Front-terminal connection and fixed circuit-breaker design. Business impact: Simplifies wiring, lowers installation time, and minimizes wiring errors on site. Application: Quick retrofit in existing Tmax XT enclosures with minimal enclosure modification. Feature III: Regulatory and material compliance. Business impact: Streamlines audits and mitigates regulatory risk through UL489/CSA certification and RoHS/CE declarations. Application: Ideal for markets with strict electrical compliance and sustainability goals. Feature IV: Packaging and logistics alignment. Business impact: 1-piece minimum order and standardized packaging simplify procurement and inventory planning. Application: Supports multi-site rollouts and just-in-time stocking for maintenance teams. Feature V: Cross-compatibility with XT4 and AC/DC rating. Business impact: Ensures reliable performance across power distribution scenarios and reduces the need for multiple accessory SKUs. Application: Broad compatibility for mixed fleet installations and future-proofing of Tmax XT systems.

Get a Quick Quote for a ABB 1SDA075710R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA075710R1? Enquire Now

FAQs

The accessory uses a front-terminal connection designed for fixed circuit-breakers and is compatible with XT4 assemblies. Follow the XT2-XT4 release assembly guidance, ensure secure terminal contact, and verify tightening torques per the SACE Tmax XT technical sheet to minimize wiring faults during commissioning.
Yes. The unit is specified as a 3P, AC/DC shunt release accessory intended for XT4 configurations within SACE Tmax XT installations, providing reliable operation across typical industrial power distributions.
The accessory aligns with UL489 standards and CSA compatibility, with RoHS compliance under EU directives 2011/65/EU and amendment 2015/863, plus a CE declaration of conformity, aiding audits and ongoing compliance in regulated environments.
Expect improved trip coordination and reduced downtime due to a purpose-built shunt release that integrates smoothly with Tmax XT 3P breakers. Front-terminal wiring simplifies maintenance and future upgrades, while RoHS/CE compliance supports safer, long-term operation.
Minimum order quantity is 1 piece, with packaging listed as box 1 piece and a dedicated EAN of 8015644796877. It is designed as a Tmax XT accessory suitable for XT4 installations, minimizing SKU proliferation and simplifying stocking for multi-site projects.