ABB 1SDA075722R1 Accessory - UL/CSA XT4 4P 80A

Part Number: 1SDA075722R1
Manufacturer
ABB
Part number
1SDA075722R1

Quick Summary

1SDA075722R1 is an ABB accessory for SACE Tmax XT4 4-pole breakers that enables a configurable shunt release for UL/CSA listed installations. Engineers often struggle with ensuring reliable remote tripping while keeping wiring simple and safe, especially in compact panels. This accessory carries UL489 and CSA CS22.2 certifications, plus CE declaration and RoHS/REACH compliance, supporting global deployments. Designed for XT4 compatibility and a 4-pole footprint, it streamlines panel assembly, reduces installation errors, and supports standard MOQs, delivering measurable procurement and operational value for electrical distribution and control cabinets.

Product Information

Extended Description

1SDA075722R1 ABB: TMA 80 400..800 4p F F XT4 4p UL/CSA
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8015644796990
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
162 mm
Package Level 1 Height
92 mm
Package Level 1 Depth / Length
100 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644796990
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT4
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
4P
Order Multiple
1 piece
Rated Current (In)
80 A
Release
TMA
Release Type
TM
Standards
UL489
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT2-XT4
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Feature: 4-pole, AC/DC operation with rated current of 80 A. Benefit: Enables reliable remote tripping for high-power Tmax XT4 configurations, reducing fault-clearing time and improving system uptime in industrial plants. Application: Suitable for SACE Tmax XT4 panels in motor control centers and distribution boards. Feature: Loose or configurable configuration type. Benefit: Offers installation flexibility to accommodate retrofit projects and evolving control schemes, lowering retrofit costs and enabling rapid deployment in existing enclosures. Application: Works across varied panel architectures without custom hardware. Feature: Front-terminal connection for fixed circuit-breakers. Benefit: Simplifies wiring, improves serviceability, and minimizes field wiring errors, enhancing installer efficiency. Application: Ideal for front-access panels and service-entitled environments. Feature: UL489/CSA certifications with CE declaration. Benefit: Ensures regulatory compliance and safer operation across North American and European sites, reducing procurement risk and accelerating approvals. Application: Critical for compliant energy distribution and machine safety programs. Feature: RoHS, REACH, CMRT and TSCA declarations. Benefit: Demonstrates environmental and supplier-risk management, supporting sustainability goals and responsible sourcing. Application: Required for global supply chains and auditable compliance. Feature: Product weight and packaging details (Net 1 kg, box packaging). Benefit: Provides predictable logistics planning and packaging efficiency for warehousing and shipping. Application: Helps procurement teams optimize stock handling and transport costs.

Get a Quick Quote for a ABB 1SDA075722R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA075722R1? Enquire Now

FAQs

To install 1SDA075722R1, first verify model compatibility with your XT4 4P breaker. Attach the accessory via front-terminal connections designed for fixed circuit-breakers, ensuring a loose or configurable configuration to match your panel layout. Follow UL489 wiring practices, perform a functional test, and verify remote tripping operation. Proper torque and enclosure clearance are essential for reliable performance and service life.
The unit supports 4-pole operation with an 80 A rated current and is suitable for AC/DC signaling. It is designed as a TMA TM release accessory for SACE Tmax XT4, aligned with UL489 and CSA CS22.2 standards. Terminal connections are front-mounted for ease of wiring, enabling compact yet robust installations in control panels.
Yes. This ABB accessory is specifically designed for SACE Tmax XT4 4-pole breakers, providing a configurable shunt release option that aligns with XT4 form factor, front-terminal wiring, and standard mounting footprints. It helps maintain consistency across new builds and retrofits while preserving existing panel architecture.
The accessory carries UL489/CSA compliance, a CE declaration, RoHS and REACH declarations, and CMRT/TSCA information. These certifications support global regulatory requirements, reduce compliance risk in multinational projects, and facilitate supplier audits and environmental reporting.
The 1SDA075722R1 provides faster remote tripping and safer maintenance with a straightforward installation. Its compatibility with XT4 reduces time spent on part selection, while UL/CSA compliance and RoHS/REACH declarations minimize cross-border procurement hurdles. Overall, expect lower lifecycle downtime costs and improved reliability in distribution and control applications.