ABB 1SDA075766R1 Accessory - UL/CSA XT4 4P 250A

Part Number: 1SDA075766R1
Manufacturer
ABB
Part number
1SDA075766R1

Quick Summary

ABB 1SDA075766R1 Accessory for Tmax XT4 enables proper integration with UL/CSA circuits. For engineers handling retrofits or new builds, lacking a compatible XT4 accessory can trigger procurement delays, mismatched components, installation retries, and costly downtime on critical lines, while increasing engineering rework time. It carries UL489 and CSA approvals and includes a CE declaration and RoHS compliance, ensuring safe, regulation-aligned field installation and traceable material compliance. In addition, this XT4 accessory streamlines sourcing across ABB ecosystems, reduces SKU proliferation, and supports reliable power distribution in industrial panels for manufacturing, water treatment, and process industries.

Product Information

Extended Description

1SDA075766R1 ABB: Ekip LSI In=250A XT4 4p UL/CSA
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8015644797430
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
110 mm
Package Level 1 Height
100 mm
Package Level 1 Depth / Length
150 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644797430
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT4
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC
Number of Poles
4P
Order Multiple
1 piece
Rated Current (In)
250 A
Release
Ekip LSI
Release Type
EL
Standards
UL489
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Ekip C Dip LSI, Ekip C Dip LSIG and LIG XT2-XT4
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Feature: Rated current 250 A per pole in a 4P configuration for XT4. Business Impact: Delivers robust current handling for large feeders, minimizing heat buildup and voltage drop, which translates to longer component life and lower maintenance costs. Application: Use in SACE Tmax XT4 installations where high-demand lines service motors, conveyors, or presses, ensuring reliable starts and smooth operation under peak loads. Feature: Compliance with UL489, CSA, RoHS, REACH, and CMRT declarations. Business Impact: Reduces risk during audits and change-control processes, while supporting sustainability reporting and supplier transparency. Application: Suitable for panel builders in North America and Europe designing with ABB accessory ecosystems and aiming for traceable, regulation-ready assemblies. Feature: Front-terminal fixed connection for fixed circuit-breakers. Business Impact: Improves mechanical robustness and simplifies terminal torqueing procedures, which shortens commissioning time and reduces wire damage risk. Application: Ideal for front-mounted connection configurations in compact switchgear and for retrofits where reliable contact integrity is critical. Feature: Loose or configurable configuration options. Business Impact: Offers installation flexibility to accommodate different mounting footprints, spare parts, and retrofits without replacing the entire assembly. Application: Enables seamless integration with existing Tmax XT panels and future XT4 upgrades. Feature: Lightweight packaging and clear product data. Business Impact: Facilitates efficient logistics, reduces handling risk, and accelerates stocking in warehouses. Application: Streamlines procurement for distributors, panel builders, and system integrators working on high-availability power distribution.

Get a Quick Quote for a ABB 1SDA075766R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA075766R1? Enquire Now

FAQs

Begin by confirming XT4 compatibility and power rating of 250 A per pole. Mount the accessory using the front-terminal interface specified for fixed circuit-breakers, ensuring all connections are torqued to the manufacturer's recommended values. Verify alignment with the Tmax XT4 busbar, then perform a standard insulation and continuity test before energizing the panel. Documentation and manuals provided by ABB should guide each step to avoid miswiring and ensure UL489 conformity.
Key specs include four poles (4P), AC current type, rated current of 250 A, and compatibility with XT4 devices. The assembly is designed for UL489/CSA environments and adheres to RoHS and REACH declarations. When selecting, ensure the panel supports fixed front-terminal connections and that the accessory is suitable for the intended XT4 configuration and load profile.
Yes. The accessory is designed to be loose or configurable, enabling flexible installation in existing Tmax XT panels without replacing the core breaker. It supports streamlined procurement and reduces SKU proliferation, aiding retrofits where space, footprints, or mounting rails vary between installations. Always verify the panel’s current rating and mounting compatibility before retrofitting.
The accessory carries UL489 and CSA approvals for low-voltage molded case breakers, a CE declaration, RoHS compliance, and REACH declarations. CMRT documentation is also available for conflict minerals reporting. This combination supports regulatory audits, environmental responsibility goals, and supplier transparency across global installations.
The accessory reduces downtime by ensuring rapid, reliable installation with front-terminal connectivity and 4P high-current capability. It simplifies sourcing through a single part suitable for Tmax XT4, minimizes change-control risk with regulatory-compliant declarations, and improves overall panel performance, contributing to lower maintenance costs and higher line uptime in manufacturing and process industries.