ABB 1SDA076535R1 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA076535R1
Quick Summary
ABB 1SDA076535R1 Moulded Case Circuit Breaker is a compact three-pole protection device designed for reliable overcurrent interruption in industrial power distribution. Engineers often face nuisance trips and downtime when protecting motors and transformers; this unit's precise trip range and front-terminal design reduce false trips and simplify wiring. It carries IEC60947-2 conformity, CE declaration, and RoHS/REACH compliance, aligning with industry safety, environmental, and regulatory expectations. Designed for quick installation and easy maintenance, it integrates with the SACE Tmax XT family and supports 32.5–100 mm² busbars to adapt to evolving panel designs.
Product Information
Extended Description
1SDA076535R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MA Iu 160 A I3=960...2240 A
Country of Origin
India (IN)
Lead Time
0 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
AETAD009EXPU
Country of Origin
India (IN)
Lead Time
0 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
BRABB008EXPU
Country of Origin
India (IN)
Lead Time
0 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CHSEC006EXPU
Country of Origin
China (CN)
Lead Time
21 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
Country of Origin
India (IN)
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
INABB003EXPU
Warranty Return
Product under warranty must be returned
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
76c3fb93-74c8-4c4f-8efa-c97be460d858 Italy (IT)
Simplified SCIP
6b0814c2-cbd4-4bba-b043-9c8858431d17 Germany (DE) | 54af5d43-4c3c-4b0e-b1e6-c03baf65eb23 Norway (NO) | 14ca9698-6954-4db9-9698-68b1f80e460b Finland (FI) | 4e49d761-4b38-4abf-a927-b5fc76b9856a Poland (PL) | 6351bbcb-0d43-42a7-a32e-6acf9b9d2cb2 Netherlands (NL) | e2cc4a4e-fe52-42d4-8a3b-0e239da48580 Netherlands (NL) | fc9a50eb-6ede-4e2c-b1a4-e8c496260a29 Netherlands (NL) | bed26d31-0e8f-470e-8df4-d305af397ecc Germany (DE) | ef3db785-4c53-4b72-b293-f2c8c44ddcf9 Denmark (DK) | cd7633a2-2517-4107-a8dc-9b9fd0335b62 Germany (DE) | 8c1a773b-3762-4555-88aa-646e6dcdf01a Croatia (HR) | 212b2528-fb2b-4213-aa47-db45f5e6f1af Czech Republic (CZ) | 23055d97-a8cb-43a8-aa87-c41931884c08 Poland (PL) | 914d19d3-a38f-47cb-86a2-0585147d3975 Sweden (SE) | 5a509ae0-2296-47c4-92d5-14b9b71a71bf Germany (DE) | ffa22373-0db4-4c85-ae66-1ed620ea7c71 Germany (DE) | 98c69e14-46d3-4534-9e3b-de2e8185c6e9 France (FR) | fe1face4-e9a5-4c69-ad79-b1b01592d749 Netherlands (NL) | 7cc34078-edb2-43f2-aa49-c4cc8178f33e Spain (ES) | 2d432de3-333a-48f9-b4b6-a8cba6aa777b Greece (GR) | b26107da-517a-4817-bea6-cef9beb729b9 Portugal (PT) | b6673167-654d-405f-9d22-aef7e7be07a6 Bulgaria (BG) | 61e7b878-412f-437a-978b-8ce6c02d702a Sweden (SE) | 0de66c90-3c44-4eec-b027-affd2d08e626 Poland (PL) | ad513e3d-793c-4016-9bf1-e7853b63107b France (FR) | 12134684-bfb6-4931-abcf-5d602e8d2cc8 Netherlands (NL) | b7f787ec-c3b4-4205-aaf6-7242451d9221 Estonia (EE)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3160MFF000XXX
E-Number (Norway)
4379392
EAN
8015644812706
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.638 kg
Package Level 1 EAN
8015644812706
Circuit Breaker Type to be Associated
Motor Protection
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 16.15 W
Rated Current (In)
160 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
960…2240 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
MA
Release Type
M
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Fixed three-pole XT2H circuit breaker with front terminals delivers robust protection in a compact form, reducing panel footprint while speeding up wiring and commissioning. Business impact: streamlined installation and easier maintenance translate to lower on-site labor costs and faster project turnover. Application: ideal for motor control centers and compact distribution boards where space efficiency matters. The unit supports high fault-rider settings (Ics up to 100 kA, Icu up to 70 kA, Ui 1000 V) to safeguard critical equipment during short circuits, minimizing downtime and damage. This enhances system reliability, particularly in transformer and motor protection scenarios within industrial facilities. Long-tail keywords such as low voltage molded case circuit breaker, XT2 family protection, and motor protection circuitry are embedded to improve discoverability. Compatibility with 32.5–100 mm² busbars and front-terminal wiring offers straightforward retrofits and panel upgrades. Addressing objections about energy use, the device shows power loss of 16.15 W per pole, contributing to more predictable cooling and energy planning. With CE, REACH, and RoHS compliance, procurement teams gain confidence in regulatory alignment and lifecycle sustainability. The overall design supports quick, tool-friendly installation and predictable maintenance cycles, reducing long-term ownership costs.
Get a Quick Quote for a ABB 1SDA076535R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA076535R1?
Enquire Now
FAQs
Yes. The ABB 1SDA076535R1 is designed as a fixed 3P XT2 unit with front terminals, compatible with SACE Tmax XT wiring practices. It accepts busbars from 32.5 to 100 mm² and requires a tightening torque of 6 N·m per terminal, simplifying retrofit and panel modernization.
The breaker is rated for In 160 A with Ui of 1000 V and Ur of 690 V. It provides Ics up to 100 kA and Icu up to 70 kA depending on voltage, with a specified instantaneous setting Ii of 960–2240 A. Opening time is 30 ms and it uses a MA release in a 3P, front-terminal configuration.
Yes. It features a CE declaration of conformity for Tmax XT2, and material disclosures show RoHS and REACH compliance along with related certifications, supporting regulatory requirements in many jurisdictions.
Front terminals simplify wiring access in tight spaces, enable faster commissioning, and ease future maintenance. The bolt-type terminals with a 6 N·m torque provide secure connections, while accessible wiring diagrams and mounting compatibility support straightforward service actions.
Warranty terms indicate products must be returned if defective under warranty, reflecting standard manufacturer guarantees. For lifecycle decisions, the XT2 design, RoHS/REACH compliance, and documented disassembly and maintenance guidance support predictable replacement planning and total cost of ownership considerations.