ABB 1SDA080300R1 Accessory for Tmax XT - TMF XT4 UL/CSA
Part Number: 1SDA080300R1
Quick Summary
ABB 1SDA080300R1 Accessory for Tmax XT enhances shunt-release integration in power distribution systems. This advance addresses retrofit challenges, inventory fragmentation, and compatibility gaps that engineers commonly face when upgrading XT protection schemes. The accessory carries UL489/CSA listings, CE declarations, and RoHS/REACH declarations to support global compliance and safe operation. By aligning with XT4 modules and SACE Tmax XT families, it delivers streamlined installation and certified performance. For panel builders and OEMs, this accessory reduces complexity while enabling scalable protection architectures and easier maintenance across multiple sites.
Product Information
Extended Description
1SDA080300R1 ABB: TMF 250-2500 3p F F XT4 3p UL/CSA
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8015644868291
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
162 mm
Package Level 1 Height
92 mm
Package Level 1 Depth / Length
100 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644868291
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT4
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
3P
Order Multiple
1 piece
Rated Current (In)
250 A
Release
TMF
Release Type
TM
Standards
UL489
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT2-XT4
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Feature → Business Impact → Application: 3P 250 A configuration with AC/DC current type supports both common industrial loads and critical infrastructure, enabling flexible protection without redesigning the panel. This translates to faster retrofits and lower engineering costs for XT4 installations in motor controls and distribution boards. Feature → Business Impact → Application: Front-mounted fixed circuit-breaker terminals simplify installation and service, reducing assembly time and minimizing wiring errors during field upgrades in SACE Tmax XT systems. Feature → Business Impact → Application: UL489 standards compliance and CE declarations ensure regulatory alignment, lowering acceptance risk with utilities and OEM customers in North America and Europe. Feature → Business Impact → Application: Product-level documentation such as CMRT, TSCA declarations, and RoHS/REACH support supply-chain transparency and risk mitigation for global projects. Feature → Business Impact → Application: Compact packaging and 1 piece MOQ streamline stocking for distributors, enabling just-in-time procurement and improved inventory turns for XT4 accessory spares.
Get a Quick Quote for a ABB 1SDA080300R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA080300R1?
Enquire Now
FAQs
Verify XT4 compatibility and 3P 250 A rating, then position the accessory for front-fixed terminal connection on the Tmax XT module. Secure with standard mounting hardware, ensuring the unit remains accessible for maintenance. Use the included release assembly guidelines for XT2–XT4 configurations to avoid misalignment and ensure proper electrical contact.
It is designed for 3 poles with AC/DC current capability and a rated current of 250 A, aligning with SACE Tmax XT protection needs. The product main type, ‘Accessories for Tmax XT,’ confirms its role as a compatible XT4 shunt-release add-on, enabling reliable operation in high-current, three-phase applications.
Yes. The accessory carries UL489 standards coverage for low-voltage molded-case circuit-breakers and CSA-related compliance, providing recognized safety and performance assurance for North American installations. This supports procurement decisions and reduces certification risk in regulated projects.
The accessory is explicitly suitable for XT4 and belongs to the SACE Tmax XT product family. It supports front-mounted, fixed-terminal connections on 3P Tmax XT breakers, facilitating straightforward retrofits and consistent performance across XT series installations.
Using genuine ABB accessories minimizes installation errors, reduces maintenance downtime, and improves spare-parts availability. Coupled with documented compliance (RoHS, REACH, CMRT, TSCA) and clear installation manuals, this approach lowers lifecycle risk and supports faster project acceptance.