ABB 1SDA080302R1 Accessory - UL/CSA Certified for Tmax XT

Part Number: 1SDA080302R1
Manufacturer
ABB
Part number
1SDA080302R1

Quick Summary

ABB 1SDA080302R1 Accessory for Tmax XT is a shunt-release component designed for XT4 power distribution. It enables panel builders and control engineers to manage breaker tripping with precision, reducing downtime during protection events. A key challenge is guaranteeing exact compatibility across different XT configurations while meeting strict regulatory demands. This accessory is specified for 3P XT4 installations and supports AC/DC control with front-terminal connections, offering flexible mounting options. It also carries UL489/CSA certifications, RoHS declaration, and REACH compliance, which helps procurement meet supplier sustainability targets. By standardizing on ABB Sace Tmax XT accessories, teams gain predictable lead times, simplified spares planning, and improved protection coordination, all within a robust, industry-accepted framework.

Product Information

Extended Description

1SDA080302R1 ABB: TMF 90-900 3p F F XT4 3p UL/CSA
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8015644868314
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
162 mm
Package Level 1 Height
92 mm
Package Level 1 Depth / Length
100 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644868314
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT4
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
3P
Order Multiple
1 piece
Rated Current (In)
90 A
Release
TMF
Release Type
TM
Standards
UL489
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
SACE Tmax XT UL/CSA Low voltage molded case circuit-breakers UL489 and CSA CS22.2 Standards Catalog | SACE Tmax XT UL/CSA TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers for UL489 and CSA CS22.2 Standards
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT2-XT4
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Feature: 3-pole AC/DC shunt-release interface enables rapid control of tripping signals; Business Impact: improves selective protection and reduces nuisance trips; Application: used in XT4 panel boards to coordinate protective relays. Feature: 90 A rated current with fixed front-terminal connections; Business Impact: supports standard power distribution loads and simplifies wiring; Application: plug-and-play with Tmax XT 3P breakers. Feature: Loose or configurable configuration type; Business Impact: flexible installation in retrofit and new builds; Application: aligns with existing control circuits. Feature: UL489/CSA, RoHS, REACH compliance; Business Impact: regulatory compliance reduces audit risk and enables global deployment; Application: multinational facilities. Feature: 1 piece minimum order quantity and packaging efficiency; Business Impact: lowers inventory risk and simplifies procurement; Application: streamlined repackaging in spare parts inventory. Compatibility: SACE Tmax XT family; Business Impact: reduces mismatch risk and simplifies sourcing; Application: standard protection setups across XT series.

Get a Quick Quote for a ABB 1SDA080302R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA080302R1? Enquire Now

FAQs

Begin by confirming the accessory is the correct model for your XT4 3P breaker. Mount the device with front-terminal connections per the Sace Tmax XT installation guide, ensuring AC/DC control wiring follows the designated polarity and lead lengths. Verify tight, vibration-free wiring, then test the tripping function in a controlled, powered-down environment before returning to service.
Compatibility is defined by 3P configuration, front-terminal connection type, loose or configurable mounting, and the 90 A rated current. The accessory is designed for SACE Tmax XT 3P breakers and supports XT4 installations, ensuring coordinated protection with UL489/CSA standards and RoHS/REACH compliance.
Yes. The product includes RoHS information and declaration, REACH declaration, and CMRT metadata, with a TSCA declaration where applicable. This alignment helps buyers meet global regulatory requirements and supports responsible supply chain practices.
The accessory is engineered for XT4 3P configurations, offering AC/DC compatibility, 3-pole operation, and front-terminal wiring. Its design supports fast, reliable shunt release operation within XT4 protection schemes, improving coordination with the main breaker and reducing nuisance trips in demanding industrial environments.
Using the ABB shunt-release accessory standardizes parts across XT4 installations, simplifying maintenance planning and spare part stocking. The 1 piece MOQ and robust regulatory certifications help reduce audit risk, streamline procurement, and shorten commissioning times, translating to lower total cost of ownership over the lifecycle of protection equipment.