ABB 1SDA080827R1 Moulded Case Circuit Breaker - IEC60947-2

Part Number: 1SDA080827R1
Manufacturer
ABB
Part number
1SDA080827R1

Quick Summary

ABB 1SDA080827R1 Moulded Case Circuit Breaker is a high-performance protection device for low-voltage switchgear and motor circuits. This solution helps prevent nuisance trips and unplanned downtime in busy control panels. It aligns with IEC 60947-2 and CE conformity, and provides RoHS and REACH compliance to support regulatory installations. By harmonizing with the SACE Tmax XT family, it simplifies procurement and installation while delivering reliable protection for automation projects.

Product Information

Extended Description

1SDA080827R1 ABB: C.BREAKER TMAX XT1N 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 16-450 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
bab57cb4-245d-44be-bf03-c5b43170495f Italy (IT)
Simplified SCIP
0ff67b66-9393-4f4b-8f5f-a17f64d2be5d Finland (FI) | 33253106-5ca0-4526-9533-bdadea09e443 Hungary (HU) | 498f8cb1-1144-4233-b2da-7f77194abdaa France (FR) | bed42174-22d5-44c5-825f-930a509434d9 Spain (ES) | c1e394ba-ae25-477b-b7eb-41d9bf76e9e1 Belgium (BE) | e0dac05e-e1bd-4d4d-9b78-cd7f3819e5b2 Germany (DE) | 3de44331-1772-443c-92d5-420b325fac62 Czech Republic (CZ) | b93fbbdb-806b-4f85-ad2e-e80a1115ec1a Croatia (HR) | 15fbfd28-b2e7-4b5d-a137-b6f169f1de24 Germany (DE) | 4051a5d0-7a42-4fde-822b-ab36eacae1e5 Sweden (SE) | f5024ea2-de39-45f6-aea7-22a156c7bcd4 Germany (DE) | 7766981b-f293-417d-8b77-4664d575a931 Denmark (DK) | 90530b91-c871-4067-8c24-b38668043f31 Germany (DE) | 8b716e70-3566-446c-a452-4d7d4fa36d8b Hungary (HU) | 5f241e40-ba8d-46ac-9bee-578c560ace2e Portugal (PT) | b24c2a99-4952-4ac7-b469-2dc063c115f3 Poland (PL) | 22cf4870-2a6b-418e-99b6-5478ece1d46d Bulgaria (BG) | fa4c15fc-e5c5-49de-bc87-f0352eb68ef8 Poland (PL) | ba3f723e-560c-46ec-a4d5-2528743cbf58 Germany (DE) | 91044a1f-bf91-4a05-a740-a940a4d580a9 Greece (GR) | fc389803-df5d-4fc1-899f-ec9386da37c6 France (FR) | b73a9713-b996-43fe-8b64-b301598e1df4 Estonia (EE) | 96aa8a9b-18fb-4323-abe1-c46b4a275506 Belgium (BE) | 8a6089c7-f76b-47ab-a558-5b3e91f2160f Norway (NO) | c4f93059-ee47-47ae-87ca-6196e662f86b Sweden (SE) | ccd75dfb-28c8-4a3c-8c48-6b229ce02d1b Netherlands (NL) | 3f24730a-504f-4421-ab70-11492729f4ec Poland (PL)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1NE3016AFF000XXX
E-Number (Finland)
3640531
E-Number (Norway)
4379223
EAN
8015644873455
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644873455
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Rated Current (In)
16 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
450 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 50 kA | (230 V AC) 50 kA | (240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 18 kA | (500 V AC) 15 kA | (525 V AC) 11 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 65 kA | (230 V AC) 65 kA | (240 V AC) 65 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 36 kA | (500 V AC) 30 kA | (525 V AC) 22 kA | (690 V AC) 6 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Release
TMF
Release Type
TM
Setting Range
16 A
Short-Circuit Performance Level
N
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Front-terminal, fixed 3P design with TMF release simplifies wiring and enables faster, safer panel assembly, reducing installation time and field wiring errors in compact control cabinets. This translates to measurable labor savings and improved first-pass assembly quality in automation projects. Feature → 16 A setting range and 690 V rated operational voltage provide precise protection for machines and feeders, enhancing uptime and reducing costly tripping events in motor-start applications. Application: motor control centers and distribution boards in manufacturing lines. Feature → Ics up to 50 kA (230/240 V) and Icu up to 65 kA (230 V) with 8 kV Uimp deliver robust short-circuit protection against fault surges, supporting safer, more reliable operation of transformers and feeders. Application: transformer protection and panel feeders. Feature → EcoSolutions and End Of Life guidance with EPD and recyclability information support sustainable design and compliance, enabling easier end-of-life planning and waste minimization. Application: green facilities and regulated industries. Feature → Front-terminal connections and compact XT1 form factor enable straightforward retrofit and compatibility with existing Tmax XT installations, reducing downtime during upgrade cycles and enabling scalable protection for expanding automation lines.

Get a Quick Quote for a ABB 1SDA080827R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA080827R1? Enquire Now

FAQs

Yes. The device is part of the SACE Tmax XT XT1 family and uses fixed front terminals for straightforward wiring. Its 3P configuration and 16 A setting are designed for quick integration into standard low-voltage panels, minimizing retrofit complexity and downtime.
At 230 V, the device provides a rated service short-circuit breaking capacity (Ics) of up to 50 kA and a rated ultimate short-circuit breaking capacity (Icu) up to 65 kA. At 380–440 V, Ics remains 36 kA and Icu remains 36 kA, offering robust protection against faults across typical industrial feeders.
Yes. It conforms to IEC 60947-2, includes CE conformity, and carries RoHS and REACH declarations. Additional environmental data includes an EPD for Tmax XT XT1 and recyclability guidance under EN45555, supporting regulatory and sustainability objectives.
Yes. The 3P XT1 breaker is designed for protection of transformers and feeders in low-voltage distribution and automation panels, offering reliable overcurrent protection, front-terminal wiring, and compatibility with the Tmax XT family for scalable installations.
Electrical durability is rated around 8000 cycles and mechanical durability around 25000 cycles, with front-terminal design facilitating replacement. Plan for periodic inspection based on your load profile and consider end-of-life guidance from ABB EcoSolutions for disassembly and recycling.