ABB 1SDA080834R1 Moulded Case Circuit Breaker - IEC60947-2

Part Number: 1SDA080834R1
Manufacturer
ABB
Part number
1SDA080834R1

Quick Summary

ABB 1SDA080834R1 is a three-pole Moulded Case Circuit Breaker designed for reliable protection of low-voltage feeders in industrial plants. Engineers often face panel space constraints, unplanned outages, and the challenge of proving compliance across multi-site operations. This XT1 Tmax device complies with IEC 60947-2, carries CE conformity and RoHS declarations, and provides an Environmental Product Declaration (EPD) for sustainability reporting. The front-terminal 3P design, 40 A rated current, and 690 V operating voltage support compact layouts and straightforward retrofit in existing switchgear. With clear maintenance instructions and lifecycle guidance, it reduces downtime during replacements and supports end-of-life recycling goals. In short, it delivers predictable protection, easier sourcing, and uptime for manufacturing and process environments.

Product Information

Extended Description

1SDA080834R1 ABB: C.BREAKER TMAX XT1S 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 40-450 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1SE3040AFF000XXX
E-Number (Norway)
4379213
EAN
8015644873622
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644873622
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Rated Current (In)
40 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
450 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 80 kA | (230 V AC) 80 kA | (240 V AC) 80 kA | (380 V AC) 50 kA | (415 V AC) 37.5 kA | (440 V AC) 25 kA | (500 V AC) 18 kA | (525 V AC) 17.5 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 3 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (240 V AC) 85 kA | (380 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 36 kA | (525 V AC) 35 kA | (690 V AC) 8 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 3 Poles in Series 50 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Release
TMD
Release Type
TM
Setting Range
28...40 A
Short-Circuit Performance Level
S
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal 3P design with fixed mounting simplifies wiring and reduces installation time. Business Impact: Faster panel builds, lower risk of loose connections, and improved frontline safety during commissioning. Application: Suitable for MCCs and distribution boards in process plants where compact footprint matters. Feature: 40 A rated current with 690 V operating capability enables scalable protection for motor loads and transformers without oversizing equipment. Business Impact: Optimized capital expenditure and improved fault clearance performance, reducing downtime. Application: Ideal for compact control rooms and Tier-1 manufacturing lines. Feature: Icu up to 85 kA and Ui of 800 V meet high short-circuit withstand requirements while maintaining safe insulation margins. Business Impact: Enhanced reliability under fault conditions and compliance with stringent plant standards. Application: Power distribution panels and feeder protection in heavy industrial environments. Feature: IEC60947-2 compliance and RoHS/CMRT/TSCA declarations streamline regulatory alignment. Business Impact: Simplified procurement, faster audits, and green reporting across global sites. Application: Global rollouts and multi-country installations. Feature: EPD availability and end-of-life disassembly guidance support sustainability goals. Business Impact: Enables accurate waste and recycling planning, lowering total cost of ownership over the lifecycle. Application: Corporate sustainability programs and asset disposition projects. Feature: Front-terminal design and clear wiring diagrams aid retrofit projects and serviceability. Business Impact: Reduced maintenance time and easier field upgrades. Application: Retrofitting existing switchgear and upgrading protection schemes in aging plants.

Get a Quick Quote for a ABB 1SDA080834R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA080834R1? Enquire Now

FAQs

Choose a panel with accessible front-terminals to simplify wiring, ensure adequate clearance for safe torqueing and inspection, and refer to the XT1 installation instructions for proper terminal torque ranges and wiring diagrams. Front-terminal design supports faster field assembly and easier future maintenance.
Rated current is 40 A, rated insulation voltage Ui is 800 V, rated operational voltage Ur is 690 V (AC) and 500 V DC. It is designed for 3P operation, with Icu up to 85 kA and a setting range of 28–40 A, making it suitable for moderate to high fault protection in MCCs.
Yes. ABB 1SDA080834R1 is manufactured to IEC60947-2 standards for low-voltage molded case circuit-breakers and carries RoHS declarations. It also aligns with CE conformity and CMRT/TSCA disclosures, supporting regulatory compliance across multiple markets.
The product includes an Environmental Product Declaration (EPD) for Tmax XT XT1, RoHS and REACH declarations, CMRT for conflict minerals, and TSCA documentation. Disassembly instructions are provided to facilitate end-of-life recycling and responsible disposal.
The XT1 design with front terminals simplifies retrofit projects, reduces wiring complexity, and shortens commissioning times. Lifecycle benefits include longer service intervals supported by durability ratings, available disassembly guidance, and sustainability data to support asset disposition and recycling programs.