ABB 1SDA080836R1 Moulded Case Circuit Breaker - IEC60947-2

Part Number: 1SDA080836R1
Manufacturer
ABB
Part number
1SDA080836R1

Quick Summary

Moulded Case Circuit Breaker ABB 1SDA080836R1 protects industrial power circuits from overloads and short circuits in switchgear and control panels. Users often struggle with coordinating protection across feeders while meeting tight maintenance windows and regulatory requirements. This device aligns with CE conformity, RoHS compliance, and IEC 60947-2 standards, complemented by DoC and environmental declarations for global acceptance. By leveraging the XT Tmax family compatibility and front-terminal XT1 design, it delivers reliable protection with straightforward installation, reducing downtime and lifecycle costs. For engineers and procurement teams, it combines robust electrical performance with clear documentation and eco-friendly attributes that support compliant, future-proof automation projects.

Product Information

Extended Description

1SDA080836R1 ABB: C.BREAKER TMAX XT1H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 20-450 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1HE3020AFF000XXX
E-Number (Norway)
4379228
EAN
8015644873646
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644873646
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Rated Current (In)
20 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
450 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 80 kA | (230 V AC) 80 kA | (240 V AC) 80 kA | (380 V AC) 52.5 kA | (415 V AC) 37.5 kA | (440 V AC) 32.5 kA | (500 V AC) 25 kA | (525 V AC) 17.5 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 52.5 kA | (500 V DC) 3 Poles in Series 52.5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 35 kA | (690 V AC) 10 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Release
TMF
Release Type
TM
Setting Range
20 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: 3P XT1 configuration with TMF release and front terminals. Business Impact: Quick, safe wiring and accurate protection Coordination, enabling faster commissioning and safer maintenance. Application: Ideal for panel builders integrating automated lines and distribution boards. Feature: Rated current 20 A with a 20 A setting range. Business Impact: Precise overcurrent protection tailored to load profiles, reducing nuisance trips and improving line reliability. Application: Automates control panels for manufacturing cells and testing rigs. Feature: High short-circuit withstand with Ics up to tens of kA depending on voltage, and Icu for lower voltages. Business Impact: Enhanced safety margins and reduced equipment damage during faults, lowering downtime costs. Application: Electrical protection in up to 690 V AC distribution networks. Feature: 690 V rated voltage and 3 poles with front terminal connections. Business Impact: Compatibility with modern low-voltage switchgear, faster installation, and convenient field servicing. Application: Transformer and motor feeder protection in automation installations. Feature: Compact dimensions (76.2 mm x 130 mm x 70 mm) and 1 kg weight. Business Impact: Space-efficient integration in crowded panels and easier handling during installation. Application: Space-constrained control cabinets and MCCs in factories. Feature: Environmentally conscious design with EPD, EN45555 recyclable rate, RoHS and CMRT compliance. Business Impact: Supports sustainability goals, regulatory compliance, and easier end-of-life planning. Application: Global deployment in regulated markets and green initiatives.

Get a Quick Quote for a ABB 1SDA080836R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA080836R1? Enquire Now

FAQs

This MCCB uses front terminals for straightforward wiring. Ensure correct pole orientation, tighten terminals to manufacturer torque specifications, and mount on a standard panel rail or panel backplane. Verify compatibility with your 690 V distribution bus and ensure the unit is clearly labeled for protection responsibilities. The XT1 shape and mounting holes align with common SACE Tmax XT enclosures for quick drop-in replacement.
Rated current is 20 A with a setting range at 20 A. Rated voltage is 690 V, with a short-circuit rating that varies by voltage level (Ics and Icu values depend on supply voltage—up to 100 kA at lower voltages and down to around 10 kA at 690 V AC). Release is TMF with a TM type, and opening time is typically around 30 ms. These specs support reliable protection in distribution and motor feeder applications.
Yes, the 3P XT1 MCCB is designed for transformer and feeder protection in low-voltage systems. Its front-terminal design, 690 V rating, and TMF release provide fast, selective tripping, reducing risk to transformers and auxiliary equipment. It fits standard switchgear and MCC configurations commonly used in automation environments.
The device carries CE conformity and RoHS compliance, with DoC documentation. It adheres to IEC 60947-2 for low-voltage molded case circuit-breakers. Additional environmental information includes EPD for Tmax XT XT1 and an EN45555 recyclability rating, supporting sustainable disposal and end-of-life planning.
With mechanical durability up to 25,000 cycles and electrical durability up to 8,000 cycles, maintenance intervals can be extended while safeguarding uptime. Front terminals enable fast swaps or upgrades, reducing service time. The compact footprint and documented wiring diagrams minimize commissioning time, contributing to lower total cost of ownership in automated production lines.