ABB 1SDA080839R1 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA080839R1
Quick Summary
ABB 1SDA080839R1 Moulded Case Circuit Breaker protects electrical circuits in industrial power distribution. Engineers often struggle to balance fast fault clearance with long-term lifecycle and easy field maintenance. This device complies with IEC60947-2 and carries CE declarations, RoHS and REACH compliance across the SACE Tmax XT XT1 family, reflecting strong environmental and regulatory alignment. Its front-terminal, fixed 3P design supports reliable, space-efficient panel mounting, while the thermal-magnetic TMD release delivers selective tripping for transformer and distribution circuits. By combining precise protection with documented recyclability and end-of-life instructions, this MCCB helps reduce maintenance downtime and support sustainable procurement. Ideal for energy-intensive industries seeking reliable protection in 690 V systems.
Product Information
Extended Description
1SDA080839R1 ABB: C.BREAKER TMAX XT1H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 40-450 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax XT | Breakers - Packaging disposal information
Order Code US and Canada
XT1HE3040AFF000XXX
E-Number (Norway)
4379216
EAN
8015644873677
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644873677
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Rated Current (In)
40 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
450 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 80 kA | (230 V AC) 80 kA | (240 V AC) 80 kA | (380 V AC) 52.5 kA | (415 V AC) 37.5 kA | (440 V AC) 32.5 kA | (500 V AC) 25 kA | (525 V AC) 17.5 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 52.5 kA | (500 V DC) 3 Poles in Series 52.5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 35 kA | (690 V AC) 10 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Release
TMD
Release Type
TM
Setting Range
28...40 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature is the TMD thermal-magnetic release, which provides fast, selective tripping for three-pole protection. Business Impact: minimizes fault duration and avoids unnecessary outages, helping maintain production continuity. Application: ideal for distribution feeders and transformer protection within 690 V systems across manufacturing sites. Feature: 3P fixed front-terminal configuration with a 40 A nominal rating and a setting range of 28–40 A. Business Impact: simplifies panel wiring and enables precise protection coordination with upstream devices. Application: suitable for machine feeders and power distribution panels in factories using 690 V grids. Feature: High short-circuit robustness with Icu up to 100 kA at low voltages and Ics up to 80 kA across common voltages; rated insulation voltage 800 V. Business Impact: enhances system resilience against motor starts and fault events, reducing upgrade costs. Application: protection for 690 V and sub-voltages in industrial switchgear. Feature: Compact, front-terminal design with dimensions 76.2 mm wide × 130 mm high × 70 mm deep and weight about 1 kg. Business Impact: enables tighter panel layouts and faster installation with predictable heat dissipation. Application: panel builders and OEMs integrating Tmax XT series into compact enclosures. Feature: Compliance and lifecycle data include IEC60947-2, RoHS, REACH, EPD options, and end-of-life disassembly instructions. Business Impact: supports regulatory filings and sustainable procurement with easy recycling planning. Application: suitable for manufacturers pursuing green supply chains and responsible disposal.
Get a Quick Quote for a ABB 1SDA080839R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA080839R1?
Enquire Now
FAQs
Yes. The device is a fixed 3P MCCB with front-terminal connections designed for compatible Tmax XT XT1 panel assemblies. It integrates into common DIN rail or panel-mounted configurations and uses a front-access wiring approach to simplify installation and future maintenance.
The breaker provides a 40 A nominal current with a 28–40 A setting range, rated voltage up to 690 V AC and 500 V DC. It delivers high fault protection with Ics up to 80 kA (at typical voltages) and Icu up to 100 kA at lower voltages, making it suitable for demanding industrial feeders and transformer protection.
Yes. It aligns with the IEC60947-2 standard, carries a CE declaration, and is RoHS and REACH compliant. Additional documentation includes the EC Declaration of Conformity for Tmax XT1 and related environmental declarations.
Product dimensions are 76.2 mm in width, 130 mm in height, and 70 mm in depth, with a net weight of 1 kg. The compact, front-terminal design facilitates tight panel layouts and straightforward wiring during installation.
The device includes end-of-life disassembly instructions and packaging recyclability data. Electrical durability is rated at up to 8000 cycles and mechanical durability up to 25000 cycles, with a typical opening time of 30 ms, supporting reliable operation in continuously loaded systems.