ABB 1SDA080844R1 XT1N MCCB - 4P, IEC60947-2 Standard
Part Number: 1SDA080844R1
Quick Summary
ABB XT1N 1SDA080844R1 MCCB is a front-terminal, four-pole molded case circuit breaker designed for reliable protection of industrial power distribution. Engineers often struggle with compact panel layouts that demand quick installation and dependable tripping under fault conditions. This unit complies with IEC 60947-2 and CE declarations, with RoHS/REACH information and an environmental footprint documented by EPDs. It also features recyclability data per EN45555 and a zero-waste-to-landfill validation option. For procurement teams, the combination of standardized protection, front-terminal accessibility and sustainability disclosures translates into simpler sourcing, lower risk, and a clearer path to regulatory compliance while supporting ESG goals in manufacturing and utilities environments.
Product Information
Extended Description
1SDA080844R1 ABB: C.BREAKER TMAX XT1N 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 25-450 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1NE4025AFF000XXX
E-Number (Finland)
3640538
E-Number (Norway)
4379231
EAN
8015644873721
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.3 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8015644873721
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Rated Current (In)
25 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
450 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 50 kA | (230 V AC) 50 kA | (240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 18 kA | (500 V AC) 15 kA | (525 V AC) 11 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 65 kA | (230 V AC) 65 kA | (240 V AC) 65 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 36 kA | (500 V AC) 30 kA | (525 V AC) 22 kA | (690 V AC) 6 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Release
TMD
Release Type
TM
Setting Range
17.5...25 A
Short-Circuit Performance Level
N
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The XT1N four-pole design with front terminals simplifies installation and maintenance in crowded switchboards, reducing commissioning time and field wiring errors in power distribution across manufacturing lines. Benefit: faster upgrades and lower labor costs during panel expansions. Application: motor control centers and transformer protection where space is at a premium. Feature → Business Impact → Application: Setting range 17.5–25 A provides precise overload protection, minimizing nuisance trips and extending equipment life. Application: tailored protection for mixed loads in process lines and critical feeders. Feature → Business Impact → Application: Icu and Ics ratings (up to 65 kA and 50 kA respectively) deliver robust fault management across 690 V systems. Application: protection for large motors and high-energy feeders in energy-intensive facilities. Feature → Business Impact → Application: RoHS/REACH, CE and EPD declarations ensure compliance with global regulations and supplier ESG requirements. Application: procurement for multinational sites with strict regulatory mandates. Feature → Business Impact → Application: Front-terminal, compact footprint and documented installation instructions streamline panel integration. Application: space-constrained panels in manufacturing, data centers and utility substations. Feature → Business Impact → Application: End-of-life disassembly guidance, packaging disposal data and 55.9% recyclability rate support sustainable lifecycle management. Application: corporate sustainability reporting and waste-minimization initiatives across asset inventories.
Get a Quick Quote for a ABB 1SDA080844R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA080844R1?
Enquire Now
FAQs
The 1SDA080844R1 XT1N is part of the Tmax XT family and uses a front-terminal, fixed 4P configuration designed for XT series assemblies. It fits standard XT1 mounting footprints and supports typical wiring schemes in 690 V AC/DC distributions. Always verify panel cutouts and clearance per the installation instructions to ensure seamless integration.
Key specs include rated insulation voltage Ui of 800 V and rated operational voltage Ur of 690 V AC / 500 V DC. Short-circuit performance features are Icu up to 65 kA and Ics up to 50 kA depending on voltage, with a setting range of 17.5–25 A and a rated impulse withstand voltage Ui of 8 kV. It is a 4-pole 690 V device with front terminals.
Yes. The XT1N MCCB carries the CE Declaration of Conformity and adheres to RoHS and REACH declarations for ABB Sace circuit breakers. It also provides environmental disclosures including EPDs and recyclable design data, supporting regulatory compliance and sustainability reporting for global installations.
Ideal for power distribution, motor feeders and transformer protection in industrial facilities, data centers and utility environments. With front-terminal access, 690 V rating, robust Icu/Ics, and a compact 4P footprint, it supports safe, maintainable protection across mixed loads while simplifying procurement within the Tmax XT ecosystem.
Sustainability features include EPD availability for Tmax XT XT1 (IT and CN versions), a recyclability metric of 55.9% per EN45555, and end-of-life disassembly instructions. Packaging disposal guidance is provided, and there is a UL 2799 Zero Waste To Landfill validation option, supporting responsible disposal and ESG commitments for project portfolios.