ABB 1SDA083125R1 Moulded Case Circuit Breaker is used to protect electrical distribution panels in industrial automation environments. This product addresses the frequent challenge of selecting a reliable, compliant protective device that fits tight panel spaces and fastens with front terminals for easier installation. It complies with RoHS and REACH, plus TSCA declarations, and aligns with IEC 60947-2 standards, ensuring safe integration into international projects. For procurement teams, predictable performance, documented specifications, and a compact footprint translate into reduced stocking complexity and faster changeouts. In addition to core protection, this device supports SACE Formula DSA configurations, offering consistency across control panels and machine safety systems. The result is improved reliability, easier maintenance, and lower total cost of ownership when scaling automation.
Product Information
Extended Description
1SDA083125R1 ABB: C.BREAKER SACE FORMULA A1N 125 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 40-400 A (DVP)
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8015644898700
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
60 mm
Product Net Weight
0.75 kg
Package Level 1 Gross Weight
0.8 kg
Product Main Type
SACE FORMULA DSA
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Number of Poles
3P
Rated Current (In)
40 A
Release
TMF
Remarks
ATLAS - FORMULA DVP
Short-Circuit Performance Level
N
Sub-type
A1
Data Sheet, Technical Information
SACE FORMULA DSA IEC Low voltage molded-case circuit-breakers up to 630A IEC 60947-2 Standard
Instructions and Manuals
Installation Instructions Formula A1/III-IV
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → Business Impact → Application: Fixed 3-pole design with TMF release and front terminals enables fast wiring and safer maintenance, reducing installation time and risk in control cabinets used in automated lines. Feature → Business Impact → Application: Rated current of 40 A with 3P protection ensures balanced distribution and reliable fault isolation for machinery feeders, minimizing unplanned downtime in manufacturing cells. Feature → Business Impact → Application: RoHS, REACH, TSCA declarations plus IEC 60947-2 compliance provide regulatory confidence and safer global sourcing for EU and US projects, aiding compliance dashboards. Feature → Business Impact → Application: Compact footprint with 76.2 mm width, 130 mm height and 60 mm depth fits standard switchgear, enabling denser panel layouts and cost-effective installations. Feature → Business Impact → Application: Front-terminal, fixed installation improves accessibility during maintenance, enabling faster servicing and reduced panel downtime in high-availability environments. Feature → Business Impact → Application: Documentation including data sheets and installation manuals supports accurate specification and reduces procurement risk for system integrators.
Get a Quick Quote for a ABB 1SDA083125R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA083125R1?
Enquire Now
FAQs
This fixed, front-terminal MCCB is designed for industrial distribution panels and control cabinets. Its compact 76.2 mm width and 130 mm height fit standard switchgear footprints, enabling straightforward integration into control panels and machine automation workflows.
Key specs include 3 poles, rated current 40 A, TMF release, and front-terminal fixed mounting. Dimensions are 76.2 mm W x 130 mm H x 60 mm D with a net weight of 0.75 kg. EAN is 8015644898700 and tariff code 85362090, guiding protection coordination and panel design.
Yes. It belongs to the SACE Formula DSA family and adheres to IEC 60947-2, making it suitable for low-voltage molded-case breaker applications in standard control panels and machine safety systems.
The product includes RoHS Declaration, REACH Declaration, TSCA declaration, CMRT, and IEC 60947-2 data sheets, along with WEEE Category 5 classification, supporting regulatory compliance and responsible end-of-life handling.
The TMF release and front-terminal design enable quicker maintenance and safer servicing, reducing downtime. Its compact footprint lowers panel costs, while compliance declarations streamline audits. Together, these factors improve uptime, safety, and total cost of ownership in automation deployments.