ABB 1SDA083169R1 Moulded Case Circuit Breaker - SACE Formula DSA
Part Number: 1SDA083169R1
Quick Summary
ABB 1SDA083169R1 moulded case circuit breaker protects industrial panels with precise overcurrent protection. Wiring complexity and unreliable trips in harsh automation environments are common pain points engineers want to eliminate. Certified to IEC 60947-2 with RoHS, REACH, CMRT and TSCA declarations, this unit supports global compliance and responsible sourcing. It also features front-terminal installation, a 4-pole configuration, and TMF release for rapid, reliable protection, reducing panel downtime. For modern control panels and safety-critical applications in industrial automation, this MCCB offers robust protection, easy sourcing, and predictable maintenance costs. Rated at 15 A, 4P with TMF release, its compact 101.6 mm width fits standard switchgear, enabling streamlined wiring and quicker commissioning.
Product Information
Extended Description
1SDA083169R1 ABB: C.BREAKER SACE FORMULA A1N 125 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 15-400 A (DVP)
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8015644899141
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
60 mm
Product Net Weight
1 kg
Package Level 1 Gross Weight
1.05 kg
Product Main Type
SACE FORMULA DSA
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Number of Poles
4P
Rated Current (In)
15 A
Release
TMF
Remarks
ATLAS - FORMULA DVP
Short-Circuit Performance Level
N
Sub-type
A1
Data Sheet, Technical Information
SACE FORMULA DSA IEC Low voltage molded-case circuit-breakers up to 630A IEC 60947-2 Standard
Instructions and Manuals
Installation Instructions Formula A1/III-IV
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
The four-pole TMF thermomagnetic release with front terminals delivers precise trip action and straightforward wiring in compact enclosures. This design reduces wiring errors and short-circuit response time, translating to less downtime during commissioning and maintenance. As part of the SACE Formula DSA family, the device provides reliable protection for distribution and motor circuits at a nominal 15 A current in a 4P configuration, enabling a single device to replace multiple components in smaller control panels and cutting spare-part inventory. Regulatory compliance is built in with RoHS, REACH declarations, CMRT supply-chain reporting, and TSCA declarations, reducing procurement risk across global sites. IEC 60947-2 conformance ensures predictable performance in line with industry norms, while the compact form factor supports easy installation in tight spaces. Front-terminal access and a robust mechanical design improve field reliability, especially in environments with vibration or dust. This MCCB is well-suited for industrial automation applications, including motor control centers, machine panels, and distribution boards, where safety and uptime are critical. Finally, the unit’s packaging and disposal considerations align with WEEE guidelines, supporting responsible end-of-life management and simplified maintenance planning for engineering teams.
Get a Quick Quote for a ABB 1SDA083169R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA083169R1?
Enquire Now
FAQs
This 4P moulded case breaker uses front terminals and fits common MCCB footprints. With a net width of 101.6 mm, height of 130 mm, and depth of 60 mm, it is designed for easy insertion into standard panel arrays, simplifying wiring and reducing enclosure depth requirements while maintaining secure, accessible terminations.
Key features include a TMF thermomagnetic release for reliable short-circuit protection, a rated current of 15 A, a 4-pole configuration, and IEC 60947-2 conformity. The device supports front-terminal wiring, quick trips in demanding environments, and predictable operate-times essential for automated machinery protection.
Yes. The 1SDA083169R1 is part of the SACE Formula DSA family, designed for low-voltage molded-case protection up to 630 A in IEC 60947-2 systems. Its 4P configuration and TMF release align with typical Formula DSA applications in distribution boards, motor control centers, and automation panels.
The unit carries RoHS and REACH declarations, CMRT for supply-chain transparency, and TSCA declarations, supporting regulatory compliance across EU and North American markets. IEC 60947-2 standard conformance ensures consistent performance, while WEEE category information guides end-of-life handling in line with industry best practices.
The device’s front-terminal wiring and 4P TMF release reduce commissioning time and wiring errors, lowering installation labor costs. Its reliability and standardization within the SACE Formula DSA line decrease spare-parts inventory, while IEC 60947-2 compliance minimizes rework risks in audits, contributing to lower total cost of ownership over the panel lifecycle.